股骨假体旋转对全膝关节置换术后髌骨位置与功能结局的影响
一项回顾性多中心研究分析全膝关节置换术中股骨假体旋转与术后髌骨位置及功能结局的关系,发现股骨假体内旋0至3°时外侧髌骨移位减少且功能评分与活动度改善更优,但与外旋0至3°相比功能结果统计学相似。
要点
- 股骨假体内旋0至3°时外侧髌骨移位较其他旋转组减少。
- 股骨假体内旋或外旋0至3°组术后髌骨倾斜最明显。
- 股骨假体内旋0至3°组功能评分与活动度改善更优。
核心结论
- 股骨假体内旋或外旋不超过3°可降低髌骨移位可能性并改善功能结局与活动度。
研究设计与样本
- 回顾性多中心研究,纳入接受常规或机器人辅助全膝关节置换术的患者。
- 常规手术股骨旋转设为相对后髁轴外旋3°,机器人手术则规划为平衡屈曲间隙并相对后髁轴定义。
- 按股骨假体旋转角度分组,从大于6°外旋至大于0至3°内旋进行增量分析。
主要发现
- 术后髌骨移位和倾斜在所有股骨旋转组间差异显著(P=0.002,P=0.005)。
- 与所有其他股骨旋转组相比,股骨假体内旋0至3°时外侧髌骨移位减少。
- 股骨假体内旋或外旋0至3°组在日出位X线片上术后髌骨倾斜最明显。
- 股骨假体内旋0至3°组术后遗忘关节评分、KOOS-JR改善、活动度及达到最小临床重要差异的患者比例显著更优。
- 但与股骨假体外旋0至3°组配对比较,上述结果统计学相似。
临床怎么用
- 全膝关节置换术中可将股骨假体旋转控制在相对后髁轴内旋或外旋不超过3°以优化髌骨轨迹和功能结局。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Patellar malalignment may occur after total knee arthroplasty (TKA) and can lead to pain and dysfunction. The purpose of this study was to examine the relationship between femoral component rotation and patellar position in TKA. METHODS: This was a retrospective, multicenter study of patients who underwent conventional or robotic-assisted TKA. In conventional cases, femoral rotation was set to 3° of external rotation relative to the posterior condylar axis; in robotic cases, femoral component rotation was planned to create balanced flexion gaps and defined relative to the posterior condylar axis. Preoperative and postoperative radiographs were analyzed to determine patellar translation, tilt, and coronal limb alignment. Knee injury and Osteoarthritis Outcome Score-Joint Replacement, range of motion (ROM), and postoperative forgotten joint scores (FJS) were collected. Cases were analyzed in incremental groups stratified by femoral component rotation, ranging from greater than 6° of external rotation to greater than 0 to 3° of internal rotation. RESULTS: Postoperative patellar translation and tilt were significantly different across all femoral rotation groups (P = 0.002, P = 0.005). Compared to all other femoral rotation groups, lateral patellar translation was reduced when femoral components were internally rotated between 0 and 3°. Conversely, those with femoral component internal or external rotation between 0 and 3° had the most postoperative patellar tilt on sunrise radiographs. Postoperative FJS, improvement in Knee injury and Osteoarthritis Outcome Score-Joint Replacement and ROM, and the proportion of patients who met the minimal clinically important difference were significantly better in patients whose femoral components were between 0 and 3° of internal rotation. However, pairwise comparisons with patients who had component external rotation between 0 and 3° demonstrated statistically similar results. CONCLUSIONS: Internal and external rotation of the femoral component of up to 3° decreases the likelihood of patellar translation, results in improved functional outcomes and ROM, and leads to improved FJS.
引用
- Leipman JH, Su L, Bash HD, et al. The Impact of Femoral Component Rotation on Patellar Position and Functional Outcomes in Total Knee Arthroplasty. J Arthroplasty. 2026. PMID: 41951066. doi:10.1016/j.arth.2026.03.087
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。