文献速递关节外科创伤骨科

保留平衡良好的活动型金属对聚乙烯全膝关节占位器治疗假体周围感染:两期翻修的潜在替代方案

Retaining Well-Balanced Articulating Metal-on-Polyethylene Total Knee Spacers for Periprosthetic Joint Infection: A Potential Alternative to Two-Stage Exchange.
PubMed 文献 · J Arthroplasty · 2026-04-01

该回顾性研究比较了48例假体周围感染患者中,23例按计划行二期翻修与25例保留平衡良好的活动型金属对聚乙烯全膝关节占位器(超过一年)的结局。保留占位器组感染复发率低(4%对17%,无显著差异),无灾难性失败,患者报告结局与二期翻修组相当。对于特定患者,保留平衡良好的活动型占位器可能作为两期翻修的替代方案。

要点

  • 保留占位器组仅1例(4%)在再植入后出现再感染,无其他再感染、脱位或假体周围骨折。
  • 保留占位器组5例因占位器无菌性松动行二期再植入,均非灾难性失败。
  • 两组最终患者报告结局无差异,保留占位器组随访平均29个月(SD=19个月)。

核心结论

  • 保留平衡良好的活动型全膝关节占位器治疗假体周围感染,感染复发率低、无灾难性失败,患者报告结局与按计划行二期翻修者相当。

研究设计与样本

  • 来自三级学术中心的回顾性综述,共纳入48例接受平衡活动型金属对聚乙烯全膝关节占位器(含髌骨组件置换)的假体周围感染患者。
  • 23例按计划在6个月内行二期翻修,25例选择保留占位器超过一年;采用独立t检验比较两组。

主要发现

  • 保留占位器组25例中5例因占位器无菌性松动行二期再植入(均非灾难性),其中1例(4%)再植入后出现再感染。
  • 保留占位器组无其他再感染、脱位、假体周围骨折或再手术;保留占位器组1例于术后47个月死于非感染性病因。
  • 按计划二期翻修组感染复发率为17%(4例),保留占位器组为4%,差异无统计学意义。
  • 两组最终患者报告结局无差异;保留占位器组24例存活患者平均随访29个月(SD=19个月)。

关键数值与推荐

  • 保留占位器组再感染率4%(1/25),按计划二期翻修组感染复发率17%(4/23),差异无统计学意义。

临床怎么用

  • 对于放置平衡良好、活动型金属对聚乙烯全膝关节占位器(含髌骨组件置换)的患者,在充分告知下可考虑保留占位器超过一年,作为两期翻修的替代选择。

局限性

  • 回顾性设计,样本量较小(48例),保留占位器组随访时间有限(平均29个月,SD=19个月),可能存在选择偏倚。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Although the gold standard for treatment of periprosthetic joint infection (PJI) is a two-stage exchange, patients may elect to retain a well-functioning spacer. The aim of this retrospective review was to evaluate the survivorship, complications, and patient-reported outcome measures (PROMs) of retained articulating total knee arthroplasty (TKA) spacers with patellar component replacement. METHODS: All PJI patients from a tertiary care academic center who received a balanced, articulating metal-on-polyethylene TKA spacer with patellar component replacement were reviewed. After the stage-one spacer, all patients were offered a second-stage exchange within six months, with some electing to retain their spacers beyond one year. Reoperations, recurrent infections, periprosthetic fractures, and PROMs were compared between scheduled second-stage revisions within 6 months and retained spacers beyond one year. Independent t-tests were used for comparisons. A total of 48 patients were included, with 23 undergoing scheduled stage-two revision and 25 electing to retain their spacer beyond one year. In the retained-spacer cohort, one died from an aseptic etiology 47 months postoperatively. Of the 24 living patients, the mean follow-up was 29 months (SD = 19 months). RESULTS: Of the 25 patients in the retained-spacer cohort, five underwent stage-two reimplantation for aseptic loosening of the spacer (none catastrophic), of which one patient (4%) had reinfection after reimplantation. There were no other reinfections, dislocations, periprosthetic fractures, or reoperations that occurred in the retained-spacer cohort. Although not significantly different, 17% (four patients) of the scheduled stage-two cohort had infection recurrence compared to 4% in the retained-spacer cohort. There were no differences in final PROMs between cohorts. CONCLUSIONS: Patients who retained well-balanced, articulating TKA spacers had low infection recurrence, no catastrophic failures, and comparable PROMs to those undergoing scheduled two-stage revision for PJI. Well-balanced articulating metal-on-polyethylene spacers may offer an alternative to two-stage revision in select patients.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Rainey JP, Blackburn BE, Certain LK, et al. Retaining Well-Balanced Articulating Metal-on-Polyethylene Total Knee Spacers for Periprosthetic Joint Infection: A Potential Alternative to Two-Stage Exchange. J Arthroplasty. 2026. PMID: 42020244. doi:10.1016/j.arth.2026.03.070

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。