文献速递关节外科

高交联聚乙烯在全髋置换20年随访中假体生存率优于传统聚乙烯

Excellent 20-Year Survivorship for Highly Cross-Linked Compared to Conventional Polyethylene in Total Hip Arthroplasty.
PubMed 文献 · J Arthroplasty · 2026-04-24

该回顾性研究比较了331例(214例高交联聚乙烯、117例传统聚乙烯)65岁以下初次全髋置换患者,使用28mm钴铬股骨头。20年时高交联聚乙烯组全因翻修生存率94%、传统聚乙烯组65%,高交联聚乙烯组无磨损相关翻修,线性磨损显著更低。

要点

  • 高交联聚乙烯组20年全因翻修生存率94%,传统聚乙烯组65%
  • 高交联聚乙烯组无聚乙烯磨损相关翻修,传统聚乙烯组为77%
  • 高交联聚乙烯组线性磨损0.029 mm/年,显著低于传统聚乙烯组0.24 mm/年

核心结论

  • 20年随访时高交联聚乙烯假体生存率显著优于传统聚乙烯,且高交联聚乙烯组无磨损相关翻修。

研究设计与样本

  • 共纳入282例患者的331髋,其中高交联聚乙烯214髋、传统聚乙烯117髋;传统聚乙烯组平均年龄59岁、体重指数31、随访18年,高交联聚乙烯组平均年龄53岁、体重指数31、随访17年。

主要发现

  • 20年时全因翻修生存率:高交联聚乙烯组94%,传统聚乙烯组65%。
  • 20年时聚乙烯磨损相关翻修生存率:高交联聚乙烯组100%,传统聚乙烯组77%。
  • 高交联聚乙烯组全因翻修风险显著低于传统聚乙烯组(风险比=0.184,P<0.001),传统聚乙烯组患者翻修可能性为高交联聚乙烯组的5倍。
  • 高交联聚乙烯组未发生聚乙烯磨损相关翻修,风险显著低于传统聚乙烯组(风险比=0.006,P=0.014)。
  • 高交联聚乙烯组平均线性磨损显著更低(0.029 vs 0.24 mm/年,P=0.007);末次随访Harris髋关节评分(高交联聚乙烯组89 vs 传统聚乙烯组91.5)和WOMAC评分(高交联聚乙烯组71.3 vs 传统聚乙烯组75.4)无显著差异。

临床怎么用

  • 对于65岁以下初次全髋置换患者,高交联聚乙烯内衬在20年随访中显示出优于传统聚乙烯的假体生存率和更低的磨损相关翻修风险。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Highly cross-linked polyethylene (HXLPE) liners have demonstrated excellent wear resistance in total hip arthroplasty (THA). However, there are limited long-term data directly comparing outcomes between HXLPE and conventional polyethylene (CPE) liners. This study compared the 20-year implant survivorship and clinical outcomes after THA with HXLPE versus CPE liners. METHODS: A retrospective review was performed for patients <65 years who underwent a primary THA at our institution between January 2000 and December 2003, using a CPE or HXLPE liner and a 28-mm cobalt-chromium femoral head. Overall, 331 hips in 282 patients were included: 214 HXLPE and 117 CPE. The mean age, body mass index, and follow-up were 59 years, 31, and 18 years in the CPE group and 53 years, 31, and 17 years in the HXLPE group, respectively. RESULTS: At 20 years, survivorship free from all-cause revision was 94% for HXLPE and 65% for CPE; survivorship free from polyethylene wear-related revision was 100% for HXLPE and 77% for CPE. The HXLPE group had a significantly lower hazard of all-cause revision compared to CPE (hazard ratio = 0.184, P < 0.001), indicating patients who received CPE were five times more likely to undergo revision. No polyethylene wear-related revisions occurred in the HXLPE group, corresponding to a significantly lower risk compared to CPE (hazard ratio = 0.006, P = 0.014). The mean linear wear was significantly lower with HXLPE (0.029 versus 0.24 mm/year, P = 0.007). At final follow-up, both the Harris Hip Score (HXLPE: 89 versus CPE: 91.5) and the Western Ontario and McMaster Universities Osteoarthritis Index (HXLPE: 71.3 versus CPE: 75.4) did not differ significantly. CONCLUSIONS: At 20-year follow-up, HXLPE had significantly improved survivorship compared to CPE, with no wear-related revisions in the HXLPE group. These findings support the long-term durability of HXLPE in THA.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Jin W, Chen AG, Benaroch LR, et al. Excellent 20-Year Survivorship for Highly Cross-Linked Compared to Conventional Polyethylene in Total Hip Arthroplasty. J Arthroplasty. 2026. PMID: 42036081. doi:10.1016/j.arth.2026.04.074

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。