陶瓷对陶瓷髋关节表面置换术后12个月步态功能改善
本研究纳入82例单侧陶瓷对陶瓷髋关节表面置换(cHRA)患者,在术前和术后12个月进行患者报告结局、体力活动自评和步态分析,并与43例年龄、性别和BMI匹配的健康对照比较。结果显示cHRA改善了PROMs、自报体力活动、最快行走速度、地面反作用力对称性和髋关节活动度,术后数据与健康对照在任何领域均无统计学差异。
要点
- cHRA术后12个月PROMs和自报体力活动较术前改善。
- 最快行走速度、地面反作用力对称性和髋关节活动度均较术前改善。
- 术后步态数据与健康对照在任何领域均无统计学差异。
核心结论
- cHRA短期结果 promising,有潜力恢复接近正常的步态模式和整体生活质量。
研究设计与样本
- 82例单侧cHRA患者纳入MHRA批准的临床研究,术前(中位1.7周)和术后(中位52.1周)进行PROMs、体力活动自评和步态分析,并与43例年龄、性别和BMI匹配的健康对照比较,使用仪器化跑台和3D运动捕捉记录动力学和运动学,采用统计参数映射分析。
主要发现
- cHRA改善了PROMs和自报体力活动。
- 最快行走速度从术前5.75 km/hr(SD 1.04)提高到7.27 km/hr(SD 0.71)。
- 地面反作用力对称指数从术前10.6%(SD 9.4)改善到0.9%(SD 2.1)。
- 髋关节活动度从术前31.7°(SD 6.2°)增加到45.9°(SD 5.3°)。
- 术后数据与健康对照在任何领域均无统计学差异。
临床怎么用
- cHRA术后12个月可改善步态对称性和行走速度,短期功能结果与健康对照相当。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIMS: A ceramic-on-ceramic hip resurfacing implant (cHRA) was developed and introduced in a Medicines and Healthcare products Regulatory Agency (MHRA)-approved clinical investigation. This study aimed to examine function and physical activity levels of patients with a cHRA implant using subjective and objective measures, both preoperatively and 12 months postoperatively. METHODS: A total of 82 unilateral cHRA patients consented to this study as part of the larger MHRA-approved clinical investigation. In addition to their patient-reported outcome measures (PROMs), self-reported measures of physical activity and gait analysis were undertaken preoperatively (median 1.7 weeks (IQR 0.6 to 4.2)) and postoperatively (median 52.1 weeks (IQR 50.0 to 53.9)). These data were then compared with data from a group of 43 age-, sex-, and BMI-matched healthy controls. Kinetics and kinematics were recorded using an instrumented treadmill and 3D motion capture. Statistical parametric mapping was used for analysis. RESULTS: cHRA improved PROMs and self-reported physical activity from preoperative levels. cHRA improved top walking speed (5.75 km/hr (SD 1.04) vs 7.27 km/hr (SD 0.71)), achieved a more symmetrical ground reaction force profile (symmetry index value: 10.6% (SD 9.4) vs 0.9% (SD 2.1)), and increased hip range of motion (31.7° (SD 6.2°) vs 45.9° (SD 5.3°)) from preoperative levels. Postoperative data were not statistically distinguishable from the healthy controls in any domain. CONCLUSION: These short-term results of cHRA appear promising, with the potential to restore a near-normal gait pattern and overall quality of life.
引用
- Maslivec A, Allott N, Guest B, et al. Functional assessment of ceramic-on-ceramic hip resurfacing arthroplasty : improvement in gait at 12 months. Bone Joint J. 2026. PMID: 41916582. doi:10.1302/0301-620X.108B4.BJJ-2025-0885.R1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。