直接前入路全髋关节置换术中透视重建骨盆倾斜的可重复性
本研究回顾性纳入325例单术者直接前入路(DAA)全髋关节置换术患者,评估术中透视重建术前站立位骨盆倾斜(PT)的精度。结果显示,术中透视在76%患者中可将站立位PT重现于±7.0°以内,95%患者重现于±13.0°以内,但术前站立位与术中AP PT相关性低(r=0.294),提示仅凭视觉透视评估存在较大变异性。
要点
- 术中透视在76%患者中可将站立位PT重现于±7.0°以内。
- 95%患者术中PT重现于±13.0°以内。
- 术前站立位与术中AP PT相关性低(r=0.294),变异性大。
核心结论
- DAA THA术中透视视觉重建站立位PT具有中等精度,约四分之三患者达到临床相关精度。
- 功能位PT重建的变异性提示仅凭视觉评估可能需要辅助验证以提高髋臼定位一致性。
研究设计与样本
- 回顾性队列研究,纳入2022年7月至2024年7月由单一术者完成的325例初次单侧DAA THA患者。
- 术前EOS站立位和坐位测量矢状面PT,并计算站立位及术中透视图像的AP PT和骶股耻骨(SFP)角。
- 两名盲法观察者独立完成所有测量,组内相关系数(ICC)大于0.80。
主要发现
- AP PT和ΔSFP(站立至坐位)角与站立位矢状面PT及ΔPT呈中至强相关,确认测量准确性。
- 术中透视在76%患者中将站立位PT重现于±7.0°以内,在95%患者中重现于±13.0°以内。
- 术前站立位与术中AP PT相关性低(r=0.294),提示变异性大。
- SFP变化(站立至仰卧)与AP PT变化呈中等相关(r=0.422),反映PT重建精度有限。
关键数值与推荐
- 主要结局为术中PT重现于站立位值±7.0°和±14.0°以内的患者比例,对应约5.0°和10.0°的前倾不准确。
- 术中透视在76%患者中重现站立位PT于±7.0°以内,在95%患者中重现于±13.0°以内。
- 术前站立位与术中AP PT相关性r=0.294;SFP变化与AP PT变化相关性r=0.422。
临床怎么用
- DAA THA术中可借助透视评估骨盆倾斜,但仅凭视觉评估可能不足以精确重建站立位功能PT。
- 对于需要高精度髋臼定位的患者,可考虑辅助验证手段以提高一致性。
局限性
- 回顾性研究设计。
- 单术者操作,结果外推需谨慎。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Precise acetabular component positioning depends heavily on accurately recreating pelvic tilt (PT) during total hip arthroplasty (THA). The direct anterior approach (DAA) facilitates intraoperative fluoroscopy for real-time assessment, yet the accuracy of recreating preoperative standing PT intraoperatively remains unexplored. This study evaluated the precision of intraoperative PT recreation between pre- and intra-operative antero-posterior (AP) radiographic images during DAA THA. METHODS: This retrospective cohort included 325 patients undergoing primary unilateral DAA THA by a single surgeon between July 2022 and July 2024. Sagittal PT was measured on preoperative EOS radiographs in both standing and sitting positions. There were two validated parameters, anteroposterior PT and the sacro-femoral-pubic (SFP) angle, that were then calculated for both standing as well as intraoperative fluoroscopic images. There were two blinded observers who independently performed all measurements using the intraclass correlation coefficient (ICC greater than 0.80). The primary outcome was the proportion of patients in whom intraoperative PT was reproduced within ± 7.0 and ± 14.0° of standing values, thresholds corresponding to approximately 5.0 and 10.0° of anteversion inaccuracy. The secondary outcomes assessed correlations between pre- and intra-operative alignment parameters. RESULTS: Both AP PT and the Delta SFP (standing-to-sitting) angle demonstrated moderate-to-strong correlations with sagittal standing PT and Delta PT, confirming measurement accuracy before intraoperative analysis. Intraoperative fluoroscopy reproduced standing PT within ± 7.0° in 76% of patients and within ± 13.0° in 95%. However, preoperative standing and intraoperative AP PT demonstrated low correlation (r = 0.294), indicating substantial variability. The change in SFP (standing to supine) demonstrated moderate correlation with the change in AP PT (r = 0.422), further reflecting the limited precision of the PT recreation. CONCLUSION: Visual fluoroscopic recreation of standing PT during DAA THA demonstrated moderate accuracy, with three-quarters of patients achieving clinically relevant precision. Variability in reproducing functional PT suggests that visual assessment alone may benefit from adjunctive verification to improve consistency in acetabular positioning.
引用
- Zepeda K, Yared T, Burgio C, et al. Pelvic Tilt Reproducibility Using Fluoroscopy in Direct Anterior Approach Total Hip Arthroplasty. J Arthroplasty. 2026. PMID: 42031183. doi:10.1016/j.arth.2026.04.059
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。