第三代柔性干骺端锥形套在翻修全膝关节置换术中的应用:至少两年随访
本研究评估了第三代柔性干骺端锥形套(FMCs)在翻修全膝关节置换术(rTKA)中治疗严重骨缺损的早期结局。共在200例rTKA中置入241个FMCs,平均随访3年(范围2至4.5年)。结果显示任何翻修生存率为98%,无菌翻修生存率为99%,无菌性松动生存率为100%,术中骨折发生率为1%。
要点
- FMCs在rTKA中提供稳定的早期固定,任何翻修生存率为98%。
- 术中骨折发生率低(1%),仅0.5%与锥形套置入相关。
- 排除感染后,所有剩余FMCs均显示稳定固定证据。
核心结论
- 第三代FMCs在rTKA中治疗严重骨缺损可提供稳定的早期固定,术中骨折率低。
研究设计与样本
- 回顾性研究,共纳入200例rTKA中置入的241个FMCs,平均年龄68岁(范围37至82岁),平均随访3年(范围2至4.5年)。
主要发现
- 末次随访时,FMCs周围未发现放射透亮线。
- 任何翻修生存率为98%,无菌翻修生存率为99%,无菌性松动生存率为100%。
- 排除感染后,所有剩余FMCs(240个锥形套)均显示稳定固定证据。
- 术中骨折2例(1%),均为2B型缺损,仅1例与锥形套置入相关(0.5%)。
关键数值与推荐
- 骨缺损采用Anderson Orthopaedic Research Institute分类。
- 翻修原因包括屈曲不稳(90例)、无菌性松动伴或不伴骨溶解(55例)和感染后再置入(27例)。
临床怎么用
- 对于rTKA中严重骨缺损,可考虑使用第三代FMCs,其术中骨折风险较低。
局限性
- 随访时间较短(平均3年),为早期结果。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Porous metal cones are commonly utilized in revision total knee arthroplasty (rTKA) to manage severe bone loss. Flexible metaphyseal cones (FMCs) allow for macrodeformation, more uniform stress distribution, and diminished peak stresses to the compromised cortical bone, potentially reducing fracture risk during impaction. This study aimed to evaluate the early outcomes of FMCs used to treat severe bone loss in rTKA. METHODS: There were 241 FMCs inserted during 200 rTKAs. A combination of femoral and tibial FMCs was used in 41 knees. The most common reasons for revision were flexion instability (90 cases), aseptic loosening with or without osteolysis (55 cases), and reimplantation postinfection (27 cases). The mean age at operation was 68 years (range, 37 to 82). The Anderson Orthopaedic Research Institute bone loss classification was used. Serial radiographs were reviewed for evidence of loosening or osseointegration, and survivorship was determined. The mean follow-up was 3 years (range, 2 to 4.5). RESULTS: At final follow-up, no radiolucent lines were identified around the FMCs. Survivorship was 98% for any revision, 99% for aseptic revision, and 100% for aseptic loosening. Excluding infection, all remaining FMCs (240 cones) demonstrated evidence of stable fixation. There were two intraoperative fractures (1%) that occurred (one femur and one tibia), both in knees with type 2B defects, with only one fracture associated with cone insertion (0.5%). There were three re-revisions (1.5%). There was one knee (0.5%) that was explanted for a recurrent infection at 6 months; one underwent irrigation and debridement with polyethylene exchange for infection (postreimplantation), and a third was revised with polyethylene exchange for arthrofibrosis. CONCLUSIONS: To our knowledge, this is the first study evaluating the clinical results exclusively for noncustomized, third-generation FMCs in rTKA. The FMCs provide stable fixation at early follow-up, and their ability to deform during impaction appears advantageous with a low rate of intraoperative fracture.
引用
- Meding LK, Meneghini RM, Buller LT, et al. Third-Generation Flexible Metaphyseal Cones in Revision Total Knee Arthroplasty: Minimum Two-Year Follow-up. J Arthroplasty. 2026. PMID: 41936471. doi:10.1016/j.arth.2026.03.017
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。