机器人辅助全膝关节置换术中髌股轨迹优化
回顾932例机器人辅助全膝关节置换术,分析股骨假体旋转与冠状位对线对髌骨轨迹及患者报告结局的影响。计划性股骨内旋在术后6周后对患者报告结局无显著差异,但所有髌骨相关并发症均发生于外翻-内旋组。
要点
- 计划性股骨内旋在术后6周后对患者报告结局无显著影响。
- 所有髌骨相关并发症均发生于外翻-内旋组。
- 应避免在外翻膝中联合过度内旋放置窄滑车沟角假体。
核心结论
- 计划性股骨内旋在术后6周后与患者报告结局无显著差异。
- 所有髌骨相关并发症均发生在外翻-内旋组。
研究设计与样本
- 回顾性分析2023年1月至2024年8月932例机器人辅助全膝关节置换术,使用基于CT的机器人平台和6°滑车沟角单半径股骨假体。
主要发现
- 病例分为外翻-外旋445例(48%)、外翻-内旋242例(26%)、内翻-外旋105例(11%)、内翻-内旋141例(15%)。
- 平均股骨假体旋转(外旋度数):外翻-外旋2.8°(范围0.2至6.5),外翻-内旋2.4°(范围0.1至5.0),内翻-外旋-0.6°(范围-3.4至0),内翻-内旋-1.0°(范围-4.2至0)。
- 髌骨相关并发症3例,其中2例再次手术,均发生于外翻-内旋组(P < 0.001)。
- 术后6周KOOS-JR评分在内翻-外旋组最低(52.3,P < 0.039)。
- 计划性股骨内旋对术后3个月和1年KOOS-JR评分无统计学显著影响,各时间点PROMIS评分无差异。
关键数值与推荐
- 股骨旋转定义为相对于经上髁轴的内旋和外旋,冠状位对线定义为相对于机械轴的内翻或外翻。
- 术后6周、3个月和1年收集患者报告结局,使用单因素方差分析和卡方检验。
临床怎么用
- 使用窄滑车沟角股骨假体时,应避免联合外翻和内旋放置。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Robotic-assisted total knee arthroplasty (RA-TKA) allows for intraoperative component positioning to personalize alignment and gaps. However, traditional trochlear designs not optimized for patellar tracking in kinematic alignment result in femoral internal rotation (IR) relative to the surgical transepicondylar axis. We sought to determine the femoral component alignment's effect on patellar tracking in RA-TKA. METHODS: We retrospectively reviewed 932 RA-TKA cases performed from January 2023 to August 2024 using a computed tomography-based robotic platform with a single radius femoral component with a 6° trochlear sulcus angle. Femoral rotation was defined as IR and external rotation (ER) relative to transepicondylar axis. Femoral coronal alignment was defined as varus (Var) or valgus (Val) relative to the mechanical axis. Patient-reported outcomes were collected at six weeks, three months, and one year postoperatively. Outcomes were analyzed using 1-way analyses of variance and Chi-square tests. RESULTS: There were 445 (48%) Var-ER, 242 (26%) Val-ER, 105 (11%) Var-IR, and 141 (15%) Val-IR cases. Mean femoral component rotation (° external) was Var-ER: 2.8° (range, 0.2 to 6.5); Val-ER: 2.4° (range, 0.1 to 5.0); Var-IR: -0.6° (range, -3.4 to 0); and Val-IR: -1.0° (range, -4.2 to 0). There were three patella-related complications, two of which had further reoperations, all of which occurred in the Val-IR cohort (P < 0.001). Knee Injury and Osteoarthritis Outcome Score for Joint Replacement at six weeks was lowest in the Var-ER cohort (52.3, P < 0.039). Planned femoral IR had no statistically significant impact on 3-month and 1-year Knee Injury and Osteoarthritis Outcome Score for Joint Replacement scores; there were no differences in Patient-Reported Outcomes Measurement Information System scores at postoperative intervals studied. CONCLUSIONS: Planned femoral IR was not associated with statistically significant differences in patient-reported outcomes beyond six weeks postoperatively. However, all patella-related complications occurred in the Val-IR cohort. We caution surgeons against placing excessive combined Val and IR with femoral implants designed with narrower trochlear sulcus angles.
引用
- Reddy H, Di Gangi C, DeGuzman G, et al. Patello-femoral Tracking Optimization in Robotic-Assisted Total Knee Arthroplasty. J Arthroplasty. 2026. PMID: 41921833. doi:10.1016/j.arth.2026.03.067
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。