旋转成形术后20年以上的步态功能:假膝运动、速度下降与能耗增加

Gait Function at 20 Years or More After Rotationplasty Shows Pseudo Knee Motion, Decreased Walking Speed, and Increased Energy Cost of Walking.
PubMed 文献 · Clin Orthop Relat Res · 2026-03-23

本研究对29例膝关节周围恶性骨肿瘤旋转成形术后中位33年的患者进行步态分析,与年龄性别BMI匹配的对照组比较,发现患者步行速度更慢、能耗更高,但假膝机制保留,功能持久且能效接近正常,无膝屈曲由健侧代偿。

要点

  • 旋转成形术后长期步行速度较对照组慢(1.2 vs 1.4 m/s),能耗更高(4.4 vs 3.5 J/kg/m)。
  • 步频和步幅均降低,对侧腿至旋转腿的双支撑期延长。
  • 大腿-小腿长度差异与步行速度、能耗及关节参数无关联。

核心结论

  • 旋转成形术后20年以上患者步行速度低于对照组且能耗更高,但能耗随随访延长未增加并接近正常值,假膝机制保留,长期功能持久且能效良好。

研究设计与样本

  • 回顾性队列研究,1980-2002年两中心70例旋转成形术(均为Winkelmann A1型)患者,最终29例纳入,中位随访33年(IQR 29-35),对照组来自机构正常数据库(能耗分析38例,步态分析27例)。

主要发现

  • 患者步行速度1.2±0.2 m/s低于对照组1.4±0.1 m/s(均差-0.2,95%CI -0.3至-0.1,p<0.001)。
  • 能耗4.4±0.7 J/kg/m高于对照组3.5±0.4 J/kg/m(均差0.9,95%CI 0.6至1.2,p<0.001)。
  • 步频100±7步/分低于对照组108±7步/分(均差-8,95%CI -11至-4,p<0.001),步幅1.4±0.2 m短于对照组1.5±0.1 m(均差-0.1,95%CI -0.2至-0.1,p=0.01)。
  • 对侧腿至旋转腿的双支撑期占步态周期13.1%±1.9%长于对照组11.8%±1.2%(均差1.4%,95%CI 0.5%至2.3%,p=0.003)。
  • 步行速度与步频强相关(r=0.7,95%CI 0.6至0.8,p<0.001),与步幅中度相关(r=0.3,95%CI 0.1至0.5,p<0.01),能耗随速度增加中度下降(r=-0.4,95%CI -0.6至-0.2,p<0.001)。

关键数值与推荐

  • 旋转成形术后患者缺乏站立相膝屈曲,健侧代偿性增加踝背屈、膝髋屈曲及地面反作用力。
  • 大腿-小腿长度差异与步行速度、能耗、关节角度或力矩无关联(基于现有样本量)。

临床怎么用

  • 可向患者说明旋转成形术后长期功能持久、能耗接近正常,但步行速度仍低于正常人群。
  • 无明确证据支持基于大腿-小腿长度差异的手术矫正策略。

局限性

  • 样本量较小(29例),部分患者失访或排除,可能影响结果代表性。
  • 对照组来自机构数据库,非随机对照,存在选择偏倚可能。
  • 缺乏与股骨截肢和保肢手术的直接比较。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Rotationplasty is a surgical procedure primarily used for malignant bone tumors around the knee when conventional limb salvage is not feasible because of tumor extent or patient preference. The procedure repurposes the ankle to function as a pseudo knee. While early outcomes are generally good, long-term gait performance in adulthood has not been well described. QUESTIONS/PURPOSES: This study addresses the following questions about patient outcomes 20 years or more after rotationplasty: (1) What are the walking speed and energy cost as well as the spatiotemporal and gait parameters compared with a control group without lower limb diseases? (2) How are walking speed and energy cost related to age, follow-up duration, and gait parameters? (3) Does thigh-shank length discrepancy correlate with the energy cost of walking and gait parameters? METHODS: Between 1980 and 2002, a total of 70 patients underwent rotationplasty (all Winkelmann Type A1) at two centers in Amsterdam. Of these, 37% (26) died, 4% (3) underwent amputation, and 9% (6) could not be traced. Of the remaining 35 patients, 6% (2) lived abroad, 9% (3) declined participation, and 3% (1) had a nonfitting prosthesis, leaving 83% (29 of 35) of patients available for evaluation at a median (IQR) follow-up time of 33 years (29 to 35). Rotationplasty was performed for osteosarcoma in 76% (22 of 29) of patients, Ewing sarcoma in 7% (2), other malignancies in 10% (3), hemangioma in 3% (1), and femoral deficiency in 3% (1), all by a single orthopaedic surgeon. This cohort included 52% (15 of 29) male and 48% (14 of 29) female patients. The control group, obtained from the institutional normative database, included 38 participants for analyses of the energy cost of walking and 27 participants for analyses of gait without lower limb diseases or systemic conditions affecting gait or energy cost, and was comparable with the rotationplasty group in age, sex, and BMI. Function was evaluated by walking speed, energy cost of walking, and gait parameters for spatiotemporal kinematics and kinetics and compared with the same parameters for the control group. Furthermore, outcomes were compared between patients with and without measurable thigh-shank length discrepancy. Statistical analyses included independent t-tests, statistical parametric mapping, and Pearson correlations. RESULTS: Compared with the control group, patients after rotationplasty walked slower (mean ± SD 1.2 ± 0.2 versus 1.4 ± 0.1 m/s, mean difference -0.2 [95% confidence interval (CI) -0.3 to -0.1]; p < 0.001) with a higher energy cost (4.4 ± 0.7 versus 3.5 ± 0.4 J/kg/m, mean difference 0.9 [95% CI 0.6 to 1.2]; p < 0.001). Cadence was lower (100 ± 7 versus 108 ± 7 steps per minute, mean difference -8 [95% CI -11 to -4]; p < 0.001) and stride length shorter (1.4 ± 0.2 versus 1.5 ± 0.1 m, mean difference -0.1 [95% CI -0.2 to -0.1]; p = 0.01). The double-support phase from the contralateral leg to the rotationplasty leg was longer (at 13.1% ± 1.9% versus 11.8% ± 1.2% of the gait cycle, mean difference 1.4% [95% CI 0.5% to 2.3%]; p = 0.003). Statistically significant differences were observed at specific phases of the gait cycle: Patients with rotationplasty lacked knee flexion during loading response and midstance, whereas the intact leg showed increased ankle dorsiflexion and greater knee and hip flexion during stance, accompanied by increased ground-reaction force in loading response and push-off. Walking speed increased very strongly as cadence increased (r = 0.7 [95% CI 0.6 to 0.8]; p < 0.001) and increased moderately as stride length increased (r = 0.3 [95% CI 0.1 to 0.5]; p < 0.01). As walking speed increased, walking energy cost decreased moderately (r = -0.4 [95% CI -0.6 to -0.2]; p < 0.001). With the numbers available, no associations were found between thigh-shank length discrepancy and walking speed, energy cost, joint angles, or joint moments. CONCLUSION: More than two decades after rotationplasty, patients demonstrated lower walking speed and higher energy cost of walking than the control group, which is expected given the magnitude of the procedure. Compared with previous reports, the energy cost was not higher at longer follow-up and approached normal values, exceeding those typically observed after transfemoral amputation. Although the absence of knee flexion during stance was associated with compensatory strategies, mainly in the contralateral limb, overall gait performance remained functional, with preserved pseudo knee mechanics. No differences were observed between patients with and without thigh-shank length discrepancy, providing no clear guidance for surgical length-correction strategies. Despite biomechanical deviations from normal gait, long-term function after rotationplasty appears durable and energy efficient, which can help clinicians to counsel patients on realistic expectations and functional potential. Further studies comparing rotationplasty with transfemoral amputation and limb-salvage surgery are warranted to better inform shared decision-making. LEVEL OF EVIDENCE: Level III, therapeutic study.

来源:Clin Orthop Relat Res,查看原文。版权归原作者所有。

引用

  1. Krebbekx GGJ, Waterval NFJ, Brehm MA, et al. Gait Function at 20 Years or More After Rotationplasty Shows Pseudo Knee Motion, Decreased Walking Speed, and Increased Energy Cost of Walking. Clin Orthop Relat Res. 2026. PMID: 41879248. doi:10.1097/CORR.0000000000003841

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。