文献速递运动医学关节外科

臀中肌修复联合髂胫束自体移植增强的生物力学比较

A Biomechanical Comparison of Gluteus Medius Repair With and Without Iliotibial Band Autograft Augmentation.
PubMed 文献 · Am J Sports Med · 2026-03-02

研究将14例新鲜冰冻半骨盆标本随机分为髂胫束增强组和非增强组,比较臀中肌双排修复的生物力学性能。结论提示髂胫束增强可提高修复强度,可能降低失败率。

核心结论

  • 髂胫束自体移植增强的臀中肌双排修复失败载荷高于非增强修复,但修复刚度低于原生状态。
  • 临床可考虑对臀中肌腱撕裂采用髂胫束增强双排修复,以潜在降低高失败率。

研究设计与样本

  • 控制性实验室研究,使用14例新鲜冰冻半骨盆标本(臀中肌腱完整),随机分为髂胫束增强组和非增强组。
  • 采用拉伸试验机进行生物力学测试,修复方式为双排缝桥构型,增强组附加髂胫束移植固定。

关键数值与推荐

  • 原生刚度评估:10 N预载2分钟,0.8 Hz下10至125 N循环150次模拟早期部分负重,再以1 mm/s准静态加载至60 N。
  • 修复后预条件:10 N预载2分钟,0.8 Hz下10至125 N循环150次,再以31 mm/min恒定位移速率加载至失败。

临床怎么用

  • 对臀中肌腱撕裂行双排修复时,可考虑联合髂胫束自体移植增强以提高失败载荷。
  • 需注意增强修复刚度低于原生状态,术后早期负重策略应个体化。

局限性

  • 标本为离体尸体验证,不能完全反映活体愈合过程。
  • 样本量较小(14例),随机分组后每组例数有限。
  • 未报告失败模式的具体分布数据。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Gluteus medius tears are an increasingly recognized cause of lateral hip pain in active individuals, yet no gold standard repair technique has been established, and failure and retear rates remain high. Iliotibial band (ITB) graft augmentation is a validated option in rotator cuff and hip labral repairs for stronger repair construct, but its biomechanical utility in gluteus medius repairs has not been investigated. HYPOTHESIS: It was hypothesized that ITB-augmented gluteus medius repairs would demonstrate superior ultimate load to failure and increased repair stiffness as compared with nonaugmented repairs. STUDY DESIGN: Controlled laboratory study. METHODS: Fourteen unpaired fresh-frozen cadaveric hemipelvises with intact gluteus medius tendons were randomized into ITB-augmented and nonaugmented groups and tested biomechanically with a tensile testing machine. Native stiffness was assessed as follows: 10-N preload for 2 minutes, 150 cycles at 0.8 Hz from 10 to 125 N to simulate early partial weightbearing, followed by a quasistatic load to 60 N at 1 mm/s. Tendons were then elevated from their anatomic footprint on the greater trochanter and repaired using double-row suture bridge configurations, with augmented repair incorporating ITB graft fixation. After preconditioning (10 N for 2 minutes, 150 cycles at 0.8 Hz from 10 to 125 N to simulate early partial weightbearing), specimens were loaded to failure at a constant displacement rate of 31 mm/min. Failure load, repair stiffness, and mode of failure were recorded. Data analysis included Shapiro-Wilk test, independent samples 2-tailed t tests, and paired t tests. RESULTS: ITB-augmented repairs demonstrated a 98% stronger failure load (mean ± SD, 294.6 ± 87.9 N) than nonaugmented repairs (149.0 ± 40.4 N; P = .002) and were significantly less stiff to their native state (28.1 ± 6.7 vs 137.6 ± 98.1 N/mm; P = .023). The stiffnesses of the native tendons were not different from each other (P = .773). CONCLUSION: Gluteus medius repairs augmented with ITB grafts led to greater failure load than nonaugmented repairs and were less stiff than the native state. CLINICAL RELEVANCE: Utilization of ITB-augmented double-row repairs when treating tears of the gluteus medius tendon can potentially reduce high failure rates.

来源:Am J Sports Med,查看原文。版权归原作者所有。

引用

  1. Perleberg TD, Featherall JT, Calibo TK, et al. A Biomechanical Comparison of Gluteus Medius Repair With and Without Iliotibial Band Autograft Augmentation. Am J Sports Med. 2026. PMID: 41772414. doi:10.1177/03635465261422619

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。