全膝关节置换术后僵硬行麻醉下手法松解失败率及预测因素
本研究分析227例全膝关节置换术后因僵硬行麻醉下手法松解(MUA)的膝关节,17.2%需再次手术干预。MUA后两周活动度较低、年龄及使用保留交叉韧带假体与失败独立相关,失败组最终功能评分和满意度均较差。
要点
- MUA后17.2%需再手术,其中74%行关节镜粘连松解、38%行翻修TKA。
- MUA后两周ROM较低、年龄及保留交叉韧带假体是失败独立预测因素。
- MUA失败者最终KSS膝关节评分、KOOS-JR、FJS-12及满意度均显著较差。
核心结论
- MUA后再手术发生率为17.2%,MUA后两周ROM较低、年龄及保留交叉韧带假体与需额外干预独立相关。
研究设计与样本
- 回顾性分析227例初次TKA后行MUA的膝关节,随访至少1年,比较需额外干预的39例(17.2%)与未需干预的174例。
主要发现
- 39例需额外手术者中29例(74%)行关节镜粘连松解、15例(38%)行翻修TKA。
- MUA后两周ROM在失败组为96.4°、对照组为107.4°(P < 0.001),1年ROM分别为103.1°与112.9°(P < 0.001)。
- 多因素分析显示年龄、保留交叉韧带假体及MUA后两周ROM与失败独立相关。
- 术前KSS功能评分、KSS膝关节评分及KOOS-JR评分两组无差异。
- 末次随访失败组KSS膝关节评分79.1 vs 89.0(P = 0.003)、KOOS-JR 65.0 vs 80.2(P < 0.01)、FJS-12 39.1 vs 62.0(P < 0.01)、Likert满意度3.5 vs 4.5(P < 0.01)。
临床怎么用
- MUA后应重视早期ROM恢复,两周ROM偏低者需警惕后续再手术风险。
- 对年龄较大或使用保留交叉韧带假体的僵硬TKA患者,MUA失败风险可能更高,应加强监测。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Manipulation under anesthesia (MUA) is a common treatment for stiffness following total knee arthroplasty (TKA). The purpose of this study was to evaluate the outcomes following MUA and identify risk factors for additional surgical intervention. METHODS: This study analyzed 227 knees that underwent MUA following primary TKA with 1-year follow-up. The 39 patients (17.2%) who required additional intervention were compared to 174 patients who underwent MUA without further interventions. There were no differences in body mass index, American Society of Anesthesiologists class, and prior knee surgeries. The mean follow-up was 38.5 months (range, 12 to 119.5) in the failure group and 39.2 (range, 12 to 124.2) in the control cohort. RESULTS: Of the 39 patients requiring additional procedures, 29 (74%) underwent arthroscopic lysis of adhesions and 15 (38%) revision TKA. Range of motion (ROM) two weeks following MUA was lower in patients who had additional interventions (96.4 versus 107.4°, P < 0.001), as was ROM at one year (103.1 versus 112.9°, P < 0.001). Multivariate analyses found age, cruciate-retaining implants, and ROM two weeks after MUA as independently associated with failure. There were no differences in preoperative Knee Society Score (KSS) Function, KSS Knee, and Knee Injury and Osteoarthritis Outcome Score for Joint Replacement scores. At the latest follow-up, patients who failed MUA had inferior KSS Knee (79.1 versus 89.0, P = 0.003), Knee Injury and Osteoarthritis Outcome Score for Joint Replacement (65.0 versus 80.2, P < 0.01), Forgotten Joint Score-12 (39.1 versus 62.0, P < 0.01), and Likert satisfaction scores (3.5 versus 4.5, P < 0.01). CONCLUSIONS: This study demonstrated a 17.2% reoperation incidence following MUA. Decreased ROM at two weeks, age, and cruciate-retaining implants were associated with additional intervention. These findings underscore the importance of early ROM recovery following MUA and the need for better understanding the biologic aspects of arthrofibrosis.
引用
- Hurn MT, Balbuena JR, Heironimus EE, et al. Failure Incidence and Predictors Following Manipulation Under Anesthesia for the Stiff Total Knee Arthroplasty. J Arthroplasty. 2026. PMID: 41865807. doi:10.1016/j.arth.2026.03.045
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。