文献速递关节外科

关节线改变对内侧单髁膝关节置换10.8年结局与生存率的负面影响

Negative Influence of Joint Line Change on 10.8-Year Outcomes and Survival of Medial Unicompartmental Knee Arthroplasty.
PubMed 文献 · J Arthroplasty · 2026-02-28

该回顾性队列纳入205例内侧单髁膝关节置换患者,平均随访10.8年,按术后关节线改变分为恢复组(<2 mm,n=125)与降低组(≥2 mm,n=80)。关节线降低组WOMAC功能评分、WOMAC总分及Forgotten Joint Score均显著更差,10.8年生存率显著更低(90.7% vs 97.5%,P=0.014);关节线降低与更高BMI为假体失败的独立危险因素。

要点

  • 关节线降低≥2 mm组临床评分显著更差,10.8年生存率显著低于恢复组。
  • 无菌性松动是最常见失败模式,占翻修原因的46.2%。
  • 关节线降低(HR 1.562)与更高BMI(HR 1.301)为假体失败独立危险因素。

核心结论

  • 关节线降低至少2 mm与内侧单髁膝关节置换平均10.8年随访时更差的临床结局和更低生存率相关。
  • 恢复关节线对获得最佳结局与生存率具有重要意义。

研究设计与样本

  • 回顾性队列研究,纳入2005年3月至2017年12月间接受内侧单髁膝关节置换的205例患者,最低随访5年,平均随访10.8年(范围5.1至18.2年)。
  • 按术后关节线恢复程度分为恢复组(关节线改变<2 mm,n=125)与关节线降低组(关节线改变≥2 mm,n=80)。
  • 影像学评估包括机械髋-膝-踝角、内侧胫骨近端角、外侧股骨远端角、关节线汇聚角及胫骨后倾角;临床评估采用WOMAC与Forgotten Joint Score;以转为全膝关节置换为终点行Kaplan-Meier生存分析。

主要发现

  • 恢复组与降低组在术后WOMAC功能评分、WOMAC总分及Forgotten Joint Score上差异均有统计学意义(均P<0.05)。
  • 随访期间共识别13例假体失败,无菌性松动为最常见失败模式,占翻修原因的46.2%。
  • 平均随访10.8年时,关节线降低组生存率显著低于恢复组(90.7%[95%CI 80.1至95.8] vs 97.5%[95%CI 89.8至99.4];P=0.014,log-rank检验)。
  • 多因素回归分析显示更高BMI(HR 1.301;P=0.046)与关节线降低(HR 1.562;P=0.029)为假体失败的独立危险因素。

关键数值与推荐

  • 关节线改变<2 mm定义为关节线恢复组,≥2 mm定义为关节线降低组。
  • 平均随访10.8年生存率:恢复组97.5%(95%CI 89.8至99.4),降低组90.7%(95%CI 80.1至95.8),组间P=0.014。
  • 假体失败独立危险因素:更高BMI(HR 1.301;P=0.046)与关节线降低(HR 1.562;P=0.029)。

临床怎么用

  • 内侧单髁膝关节置换术中应重视关节线恢复,避免关节线降低≥2 mm以改善临床结局与假体生存。
  • 对BMI较高的患者应加强术前评估与术后随访,因其假体失败风险更高。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: This study aimed to investigate the effect of changes in joint line height on clinical outcomes and survival rates of unicompartmental knee arthroplasty (UKA) for medial compartmental knee osteoarthritis at a mean follow-up of 10.8 years METHODS: We reviewed 205 patients who underwent medial UKA between March 2005 and December 2017 and had a minimum follow-up of five years. The mean overall follow-up duration was 10.8 years (range, 5.1 to 18.2). Patients were divided into two groups based on the degree of joint line restitution following surgery: the restored joint line group (joint line change less than 2 mm; n = 125) and the joint line lowering group (joint line change ≥ 2 mm; n = 80). Radiographic evaluations included the mechanical hip-knee-ankle angle, medial proximal tibial angle, lateral distal femoral angle, joint line convergence angle, and posterior tibial slope. Clinical outcomes were assessed using the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) and the Forgotten Joint Score. Kaplan-Meier survival analysis was performed using conversion to total knee arthroplasty as the endpoint. RESULTS: There were significant differences in postoperative WOMAC function score, WOMAC total score, and Forgotten Joint Score between the restored joint line group and the joint line lowering group (all P < 0.05). During the follow-up period, 13 implant failures were identified, with aseptic loosening being the most common mode of failure, accounting for 46.2% of revisions. At a mean follow-up of 10.8 years, survival rates were significantly lower in the joint line lowering group (90.7% [95% confidence interval, 80.1 to 95.8]) than the restored joint line group (97.5% [95% confidence interval, 89.8 to 99.4]; P = 0.014, log-rank test). Multivariate regression analyses identified higher body mass index (hazard ratio 1.301; P = 0.046) and joint line lowering (hazard ratio, 1.562; P = 0.029) as independent risk factors for implant failure. CONCLUSION: Joint line lowering of at least two mm was associated with worse clinical outcomes and lower survival rates following UKA at a mean follow-up of 10.8 years. These findings underscore the importance of restoring the joint line to achieve optimal outcomes and survival after UKA for medial compartmental knee osteoarthritis.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Yang HY, Song EK, Zheng Y, et al. Negative Influence of Joint Line Change on 10.8-Year Outcomes and Survival of Medial Unicompartmental Knee Arthroplasty. J Arthroplasty. 2026. PMID: 41771362. doi:10.1016/j.arth.2026.02.042

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。