文献速递关节外科

滑液C反应蛋白在膝髋假体周围感染诊断中效用有限:提出新诊断截断值

The Limited Utility of Synovial C-Reactive Protein in the Diagnosis of Knee and Hip Periprosthetic Joint Infection: Proposed New Diagnostic Cutoffs.
PubMed 文献 · J Arthroplasty · 2026-02-21

本研究纳入107例膝或髋人工关节置换术后患者,依据2018国际共识会议标准分类假体周围感染,评估滑液CRP>6.9 mg/L的诊断效能。结果显示该阈值敏感性较低,膝和髋分别为68.8%和75.0%,可能致假阴性;Youden指数确定膝3.43 mg/L、髋2.86 mg/L为更优阈值。滑液与血清CRP正相关,但血清CRP的AUC在膝和髋均不低于滑液CRP。

要点

  • 滑液CRP>6.9 mg/L诊断膝髋假体周围感染敏感性低,易假阴性。
  • 膝和髋最佳滑液CRP阈值分别为3.43 mg/L和2.86 mg/L。
  • 血清CRP在膝和髋的诊断AUC均不低于滑液CRP。

核心结论

  • 滑液CRP阈值6.9 mg/L在膝和髋假体周围感染诊断中敏感性低,可能导致假阴性。
  • 降低滑液CRP阈值可提高敏感性,但血清CRP在膝和髋的诊断效能仍更优。

研究设计与样本

  • 回顾性分析107例人工关节置换术后患者,其中全膝关节置换86例(80.4%),全髋关节置换21例(19.6%)。
  • 依据2018国际共识会议标准将病例分类为感染阳性、不确定或阴性。

主要发现

  • 膝关节滑液CRP>6.9 mg/L诊断假体周围感染的敏感性68.8%、特异性97.8%、阳性预测值95.7%、阴性预测值81.8%、准确率85.9%。
  • 髋关节滑液CRP>6.9 mg/L诊断假体周围感染的敏感性75.0%、特异性92.3%、阳性预测值85.7%、阴性预测值85.7%、准确率85.7%。
  • Youden J统计量确定膝和髋最佳滑液CRP阈值分别为3.43 mg/L和2.86 mg/L。
  • ROC曲线分析显示膝滑液和血清CRP的AUC分别为0.910和0.954,髋分别为0.885和0.886。
  • 滑液与血清CRP在膝(ρ=0.804,P<0.001)和髋(ρ=0.800,P<0.001)均呈正相关。

关键数值与推荐

  • 2018国际共识会议标准用于假体周围感染分类。
  • 滑液CRP>6.9 mg/L为评估的初始诊断阈值。
  • Youden J统计量确定膝最佳阈值3.43 mg/L,髋最佳阈值2.86 mg/L。

临床怎么用

  • 临床解读滑液CRP诊断假体周围感染时应谨慎,注意低敏感性导致的假阴性可能。
  • 血清CRP在膝和髋的诊断效能均不低于滑液CRP,可优先参考。
  • 若使用滑液CRP,膝和髋可考虑更低阈值(3.43 mg/L和2.86 mg/L)以提高敏感性。

局限性

  • 样本量较小(107例),髋关节病例仅21例。
  • 滑液CRP与血清CRP相关性高,可能影响独立诊断价值。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The utility of synovial C-reactive protein (CRP) in diagnosing periprosthetic joint infection (PJI) remains controversial. This study examined the performance of synovial CRP for PJI diagnosis following total knee arthroplasty and total hip arthroplasty. METHODS: In total, 107 patients (86 total knee arthroplasty [80.4%], 21 total hip arthroplasty [19.6%]) were included for analysis. Using the 2018 International Consensus Meeting criteria, cases were categorized as positive, inconclusive, or negative for PJI. Per criteria, the sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of a synovial CRP greater than 6.9 mg/L were calculated. Area under the receiver operating characteristic curve (AUC) analysis was performed, and Youden J-statistic identified an optimal diagnostic threshold. Synovial and serum CRP correlation was examined. RESULTS: In knees, synovial CRP had a sensitivity of 68.8%, specificity of 97.8%, PPV of 95.7%, NPV of 81.8%, and accuracy of 85.9%. In hips, synovial CRP had a sensitivity of 75.0%, specificity of 92.3%, PPV of 85.7%, NPV of 85.7%, and accuracy of 85.7%. Youden J-statistic identified optimal synovial CRP thresholds of 3.43 mg/L in knees and 2.86 mg/L in hips. Receiver operating characteristic curve analysis of synovial and serum CRP identified AUCs of 0.910 and 0.954 for knees and 0.885 and 0.886 for hips, respectively. Synovial and serum CRP were positively correlated in both knees (ρ = 0.804, P < 0.001) and hips (ρ = 0.800, P < 0.001). CONCLUSIONS: A synovial CRP threshold of 6.9 mg/L was associated with a low sensitivity and may lead to false-negative results in both knees and hips. While a lower synovial CRP threshold improved sensitivity, serum CRP remained superior by this measure at both the knee and hip. Surgeons should interpret synovial CRP with caution during the diagnostic workup of PJI.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. McCavitt DG, Culler MW, Palmer RC, et al. The Limited Utility of Synovial C-Reactive Protein in the Diagnosis of Knee and Hip Periprosthetic Joint Infection: Proposed New Diagnostic Cutoffs. J Arthroplasty. 2026. PMID: 41730395. doi:10.1016/j.arth.2026.02.030

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。