文献速递关节外科

丝素蛋白网在关节置换术中显著减少皮肤反应:与氰基丙烯酸酯胶粘剂的比较

Silk Fibroin Mesh Significantly Reduces Skin Reactions Compared to Cyanoacrylate Adhesives in Total Joint Arthroplasty.
PubMed 文献 · J Arthroplasty · 2026-02-18

这项回顾性队列研究比较了全关节置换术中氰基丙烯酸酯网(CM)与丝素蛋白网(SFM)伤口闭合系统,发现CM组医疗黏合剂相关皮肤损伤(MARSI)发生率显著高于SFM组(4.7% vs 1.2%,P=0.03),且CM使用、TKA手术和肥胖是MARSI的独立危险因素,SFM是降低MARSI风险的 promising 替代选择。

要点

  • CM组MARSI发生率4.7%,SFM组1.2%,差异有统计学意义(P=0.03)。
  • TKA术后MARSI发生率:CM 13.4% vs SFM 2.3%(P=0.01);THA术后无显著差异。
  • CM使用(OR 4.41)、TKA(OR 4.11)和肥胖(OR 2.67)与MARSI独立相关。

核心结论

  • SFM是传统CM的有前景的伤口敷料替代品,可降低医疗黏合剂相关皮肤损伤风险。

研究设计与样本

  • 回顾性队列研究,纳入797例患者共874例关节置换术,其中626例使用CM,248例使用SFM。

主要发现

  • CM组MARSI发生率4.7%,SFM组1.2%(P=0.03)。
  • TKA术后MARSI发生率:CM 13.4% vs SFM 2.3%(P=0.01);THA术后:CM 2.5% vs SFM 0.63%(P=0.21)。
  • 多变量逻辑回归显示CM使用(OR 4.41 [1.45 to 19.2],P=0.020)、TKA手术(OR 4.11 [1.81 to 9.34],P<0.001)和肥胖(OR 2.67 [1.17 to 6.52],P=0.023)是MARSI的独立相关因素。
  • 两组在MARSI管理和伤口相关并发症方面无差异。

临床怎么用

  • 对于接受全关节置换术的患者,尤其是TKA或肥胖患者,可考虑使用SFM伤口闭合系统以降低MARSI风险。

局限性

  • 回顾性研究设计,证据等级为III级。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Medical adhesive-related skin injuries (MARSI) are common complications associated with traditional cyanoacrylate-based adhesives, leading to a range of adverse patient outcomes. Silk fibroin mesh (SFM) has emerged as a biocompatible alternative, designed to minimize these reactions while maintaining effective wound support; however, comparative data assessing its effectiveness in reducing wound complications remain limited. This study compared the incidence of MARSI, particularly allergic contact dermatitis, between cyanoacrylate mesh (CM) and SFM wound closure systems in total joint arthroplasty. METHODS: All primary total hip (THA) and knee arthroplasty (TKA) cases at our institution that utilized CM or SFM wound closure were retrospectively reviewed. Revision arthroplasty, hemiarthroplasty, unicompartmental knee arthroplasty, and fracture fixation were excluded. The final cohort included 797 patients and 874 arthroplasty procedures, of which 626 utilized CM and 248 utilized SFM. Demographic characteristics, MARSI incidence, treatment patterns, and wound outcomes were collected and analyzed. RESULTS: The incidence of MARSI was significantly higher with CM than SFM (4.7 versus 1.2%, P = 0.03). When stratified by procedure, MARSI occurred more frequently following TKA than THA for both dressing types (TKA: 13.4 CM versus 2.3% SFM, P = 0.01; THA: 2.5 CM versus 0.63% SFM, P = 0.21). On multivariable logistic regression, CM use (odds ratio (OR) 4.41 [1.45 to 19.2], P = 0.020), TKA procedure (OR 4.11 [1.81 to 9.34], P < 0.001), and obesity (OR 2.67 [1.17 to 6.52], P = 0.023) were independently associated with MARSI. There were no differences observed in MARSI management or wound-related complications between groups. CONCLUSIONS: Silk fibroin mesh (SFM) is a promising wound dressing alternative to traditional CM, offering a lower risk of medical adhesive-related skin injury. LEVEL OF EVIDENCE: III, retrospective cohort study.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Paul BR, Van Schuyver PR, Braithwaite CL, et al. Silk Fibroin Mesh Significantly Reduces Skin Reactions Compared to Cyanoacrylate Adhesives in Total Joint Arthroplasty. J Arthroplasty. 2026. PMID: 41720318. doi:10.1016/j.arth.2026.02.027

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。