Alpha防御素侧流检测在髋膝关节置换术后假体周围感染中的诊断准确性
本研究回顾性分析2020至2023年单中心473例ADLFA检测(141例全髋、332例全膝),以2018 MSIS标准(排除ADLFA)诊断PJI。ADLFA总体敏感性80%、特异性97%、PPV 92%、NPV 92%。近期使用抗生素者NPV较低(76% vs 94%,P<0.001),间隔器抽吸敏感性较低(57% vs 82%,P=0.04),THA敏感性低于TKA(67% vs 84%,P=0.033),TKA中炎症性关节病者特异性较低(91% vs 99%,P=0.02)。
要点
- ADLFA诊断PJI总体特异性高(97%),但敏感性中等(80%)。
- 近期使用抗生素显著降低NPV(76% vs 94%,P<0.001)。
- 间隔器抽吸敏感性低(57%),THA敏感性低于TKA(67% vs 84%)。
核心结论
- ADLFA诊断PJI具有高特异性,但在抗生素间隔器患者和THA中敏感性较低,TKA中炎症性关节病可能降低特异性。
研究设计与样本
- 单中心回顾性研究,纳入2020至2023年141例THA和332例TKA共473次ADLFA检测,平均年龄66岁,51%女性,平均BMI 32。
- PJI诊断依据2018 MSIS标准(排除ADLFA),共142例PJI;49%为初次置换,51%为翻修,22%在关节穿刺前两周内使用抗生素,18%有炎症性关节病,7%有原位间隔器。
主要发现
- ADLFA总体敏感性80%、特异性97%、阳性预测值92%、阴性预测值92%。
- 假阴性29/473(6%),其中38%在穿刺前两周内使用抗生素,21%为间隔器抽吸。
- 近期使用抗生素者NPV为76%,未使用者为94%(P<0.001)。
- 间隔器抽吸敏感性57%,非间隔器抽吸82%(P=0.04);THA敏感性67%,TKA 84%(P=0.033)。
- TKA中炎症性关节病者特异性91%,无炎症性关节病者99%(P=0.02)。
关键数值与推荐
- PJI诊断采用2018 MSIS标准(排除ADLFA),共142例PJI。
- ADLFA总体敏感性80%、特异性97%、PPV 92%、NPV 92%。
- 近期使用抗生素者NPV 76% vs 94%(P<0.001);间隔器抽吸敏感性57% vs 82%(P=0.04);THA敏感性67% vs TKA 84%(P=0.033);TKA炎症性关节病特异性91% vs 99%(P=0.02)。
临床怎么用
- ADLFA可作为排除PJI的高特异性辅助检测,但阴性结果在近期使用抗生素、间隔器抽吸或THA患者中可靠性降低。
- TKA合并炎症性关节病时需警惕ADLFA假阳性,应结合其他诊断标准综合判断。
局限性
- 单中心回顾性设计可能限制普遍性;未报告其他潜在影响因素。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Accurate diagnosis of periprosthetic joint infection (PJI) remains suboptimal. Of the tests used, one is the alpha defensin lateral flow assay (ADLFA). This study assessed ADLFA for the diagnosis of PJI in total hip arthroplasties (THAs) and total knee arthroplasties (TKAs). We hypothesized that ADLFA would have high specificity and sensitivity for diagnosing PJI, but that certain clinical features would influence test reliability. METHODS: We reviewed 473 ADLFA tests from 141 THAs and 332 TKAs performed from 2020 to 2023 at a single institution. The mean age was 66 years, 51% were women, and mean body mass index was 32. There were 142 PJIs (2018 Musculoskeletal Infection Society criteria excluding ADLFA). Overall, 49% were primary and 51% revision procedures, 22% were on antibiotics within two weeks of arthrocentesis, 18% had an inflammatory arthropathy, and 7% had an in situ spacer. RESULTS: The overall sensitivity, specificity, positive predictive value, and negative predictive value of ADLFA were 80, 97, 92, and 92%, respectively. There were 6% (29 of 473) that had false negative results, of which 38% were on antibiotics within two weeks of arthrocentesis and 21% of which were spacer aspirations. The negative predictive value was lower for those who had recent antibiotic use (76%) compared to those who did not (94%; P < 0.001). There was lower sensitivity (57%) for spacer compared to nonspacer aspirations (82%; P = 0.04). Furthermore, sensitivity in THA (67%) was lower compared to TKA (84%; P = 0.033). In TKAs, there was lower specificity (91%) for those who had inflammatory arthropathies (99%; P = 0.02). CONCLUSIONS: The ADLFA is highly specific in diagnosing PJI and is less sensitive in patients who have antibiotic spacers and those who have THAs compared to TKAs. Additionally, underlying inflammatory arthropathies may decrease specificity, yielding false positive results, specifically in TKAs.
引用
- Wu M, Bukowski BR, Hickman JA, et al. Diagnostic Accuracy of Alpha Defensin Lateral Flow Assay in Total Hip and Knee Arthroplasty. J Arthroplasty. 2026. PMID: 41720320. doi:10.1016/j.arth.2026.02.026
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。