文献速递脊柱外科

超声引导下腰椎手术节段定位的结构化工作流程

A Structured Ultrasound-Guided Workflow for Level Identification in Lumbar Spine Surgery.
PubMed 文献 · Spine (Phila Pa 1976) · 2026-02-11

一项尸体验证研究评估了四步超声引导工作流程在腰椎手术节段定位中的准确性。在10具新鲜冷冻尸体上共评估50个腰椎节段,透视验证显示49/50例准确,准确率98%。唯一误判发生在L5-S1的第三步,将S1上关节突误判为L5下关节突。

要点

  • 四步超声引导工作流程在尸体标本中实现98%的腰椎节段定位准确率。
  • 唯一误判发生在L5-S1水平,因S1上关节突被误认为L5下关节突。
  • 该流程可重复,为无辐射的术前腰椎节段验证提供了初步依据。

核心结论

  • 四步超声引导工作流程在尸体标本中展现出高准确性的腰椎节段定位能力。

研究设计与样本

  • 尸体验证研究,使用10具新鲜冷冻尸体,每具放置5根脊柱针(L1-2至L5-S1),共评估50个腰椎节段,25例从右侧、25例从左侧操作。

主要发现

  • 透视验证显示49/50例节段定位准确,准确率为98%。
  • 唯一误判发生在L5-S1节段工作流程第三步,将S1上关节突误判为L5下关节突。
  • 未观察到系统性错误模式,四步协议在标本间可重复。

关键数值与推荐

  • 节段误判定义为针尖投影轨迹违反预设的放射学边界。
  • 四步协议包括:中线定位、骶骨表面追踪、S1上关节突识别、椎板间间隙计数。

临床怎么用

  • 该超声引导工作流程可作为腰椎手术节段定位的无辐射替代方案,但需进一步临床验证。

局限性

  • 本研究为尸体可行性研究,结果需在临床环境中进一步验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

STUDY DESIGN: Cadaveric validation study. OBJECTIVE: To evaluate the accuracy of a structured four-step ultrasound (US)-guided workflow for lumbar spinal level identification (SLI) using cadaveric specimens. SUMMARY OF BACKGROUND DATA: Despite the routine use of fluoroscopic verification, wrong-level spinal surgery continues to be a documented and concerning complication. Fluoroscopy exposes patients and staff to ionizing radiation and requires specialized personnel and infrastructure. The US has been utilized for SLI in obstetric and anesthetic applications, but remains underexplored in surgical workflows. MATERIALS AND METHODS: Ten fresh-frozen cadavers underwent US imaging to identify lumbar levels. A newly developed four-step protocol was used: (1) midline localization, (2) sacral surface tracing, (3) S1-superior articular process (SAP) recognition, (4) interlaminar space enumeration. Five spinal needles were placed under US guidance in each specimen (L1-2 through L5-S1), with one needle per level. Fluoroscopic imaging was then used to confirm needle placement accuracy. A level was defined as misidentified if the projected trajectory from the needle tip violated predefined radiographic boundaries. RESULTS: A total of 50 lumbar levels were assessed across 10 cadaveric specimens, with 25 procedures performed from the right side and 25 from the left. Fluoroscopic validation demonstrated accurate level identification in 49/50 cases, yielding an accuracy rate of 98%. The single misidentification occurred at the L5-S1 level during the third step of the workflow, where the S1 SAP was erroneously interpreted as the L5 inferior articular process. No systematic error patterns were observed, and the four-step protocol proved reproducible across specimens. CONCLUSION: This cadaveric feasibility study establishes a high accuracy of US-guided lumbar level identification. A structured and reproducible workflow for level localization was established, integrating a novel four-step protocol. These findings represent a first step toward a radiation-free alternative for preoperative lumbar level verification in spinal surgery. Further investigations are warranted to validate these results in clinical settings.

来源:Spine (Phila Pa 1976),查看原文。版权归原作者所有。

引用

  1. Loggia G, Soffin EM, Avrumova F, et al. A Structured Ultrasound-Guided Workflow for Level Identification in Lumbar Spine Surgery. Spine (Phila Pa 1976). 2026. PMID: 41701612. doi:10.1097/BRS.0000000000005660

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。