文献速递运动医学关节外科

股骨隧道内移植物长度较短不损害联合前交叉韧带与 anterolateral 韧带重建后移植物愈合与临床结局

Short Femoral In-Tunnel Graft Length Does Not Compromise Graft Healing and Clinical Outcomes After Combined Anterior Cruciate Ligament and Anterolateral Ligament Reconstruction Using Hamstring Autograft.
PubMed 文献 · Am J Sports Med · 2026-01-27

本研究回顾性分析180例采用腘绳肌自体移植物行前交叉韧带重建(ACLR)联合 anterolateral 韧带重建(ALLR)的患者,术中股骨隧道内移植物长度(FTGL)目标为10-15 mm。结果显示移植物失败率为3.9%,平均术后MRI测量FTGL为12.6±2.6 mm,较短FTGL亚组股骨隧道增宽较小,结论认为该目标在临床可接受。

要点

  • 联合ACLR与ALLR术中FTGL目标10-15 mm时移植物失败率为3.9%。
  • mFTGL≤12.6 mm组股骨隧道增宽60.1%±30.7%,小于>12.6 mm组的74.3%±37.2%(P=.008)。
  • mFTGL(β=3.28)与移植物直径(β=-23.86)与股骨隧道增宽独立相关(P<.001)。

核心结论

  • 在联合ACLR与ALLR中,术中FTGL目标10-15 mm在移植物失败、移植物愈合和临床结局方面临床可接受;较短FTGL亚组股骨隧道增宽较小。

研究设计与样本

  • 病例系列,证据等级4级;回顾性分析连续纳入的180例膝关节,均行初次单束ACLR(四股半腱肌自体移植物)联合ALLR(股薄肌自体移植物),至少随访2年。

主要发现

  • 移植物失败率为3.9%,平均mFTGL为12.6±2.6 mm。
  • 组1(mFTGL≤12.6 mm)股骨SNQ_tunnel隧道口与近端差值0.9±3.3,组2(mFTGL>12.6 mm)为2.3±3.9(P=.014)。
  • 组1股骨隧道增宽60.1%±30.7%,组2为74.3%±37.2%(P=.008)。
  • 多因素回归分析中,mFTGL(β=3.28;P<.001)和移植物直径(β=-23.86;P<.001)与股骨隧道增宽独立相关。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: In combined anterior cruciate ligament reconstruction (ACLR) and anterolateral ligament reconstruction (ALLR) using hamstring autografts, a femoral in-tunnel graft length (FTGL) of at least 15 mm has traditionally been recommended. However, achieving this length is not always feasible. PURPOSE: To evaluate graft healing and clinical outcomes in patients with an intraoperative FTGL target of 10 to 15 mm, and to investigate whether shorter postoperative magnetic resonance imaging (MRI)-measured FTGL (mFTGL) within this cohort affected outcomes through subgroup analysis. STUDY DESIGN: Case series; Level of evidence: 4Methods:The records of patients who underwent primary single-bundle ACLR using a quadrupled semitendinosus autograft and ALLR using a gracilis autograft, with a minimum 2-year follow-up, were retrospectively reviewed. During surgery, the FTGL was intentionally set to fall within the 10- to 15-mm range. Postoperatively, the graft length within the femoral tunnel was measured on postoperative day 2 MRI (mFTGL) and used for analyses. Graft healing was evaluated using 6-month MRI scans: (1) graft incorporation, assessed by the signal-to-noise quotient (SNQ) at the tunnel (SNQ_tunnel), signal intensity at the graft-bone interface, and tunnel widening; and (2) graft ligamentization, assessed by the SNQ of the graft (SNQ_graft) and Howell grade. Clinical outcomes were also assessed. For subgroup analysis, patients were classified into group 1 (mFTGL ≤12.6 mm) and group 2 (mFTGL >12.6 mm). RESULTS: A total of 180 knees were consecutively enrolled; 169 completed the 6-month MRI evaluation. The graft failure rate was 3.9%. The mean mFTGL was 12.6 ± 2.6 mm. In subgroup analysis, the femoral SNQ_tunnel difference between the tunnel aperture and proximal site was 0.9 ± 3.3 for group 1 and 2.3 ± 3.9 for group 2 (P = .014). Femoral tunnel widening was 60.1% ± 30.7% for group 1 and 74.3% ± 37.2% for group 2 (P = .008). In multiple regression analysis, mFTGL (β = 3.28; P < .001) and graft diameter (β = -23.86; P < .001) were independently associated with femoral tunnel widening. CONCLUSION: In combined ACLR and ALLR, an intraoperative FTGL target of 10 to 15 mm was clinically acceptable regarding graft failure, graft healing, and clinical outcomes. The subgroup with shorter FTGL showed less femoral tunnel widening.

来源:Am J Sports Med,查看原文。版权归原作者所有。

引用

  1. Cho YT, Bai JW, Yang Y, et al. Short Femoral In-Tunnel Graft Length Does Not Compromise Graft Healing and Clinical Outcomes After Combined Anterior Cruciate Ligament and Anterolateral Ligament Reconstruction Using Hamstring Autograft. Am J Sports Med. 2026. PMID: 41591922. doi:10.1177/03635465251404911

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。