文献速递运动医学关节外科

外侧关节外肌腱固定股骨固定方式对前交叉韧带重建移植物失败率的影响:系统综述与Meta分析

The Effect of Lateral Extra-articular Tenodesis Femoral Fixation Methods on Graft Failure Rates in Anterior Cruciate Ligament Reconstruction: A Systematic Review and Meta-analysis.
PubMed 文献 · Am J Sports Med · 2026-01-23

该系统综述与Meta分析纳入17项研究、2527例前交叉韧带重建(ACLR)患者,其中1254例接受改良Lemaire外侧关节外肌腱固定(LET)增强。ACLR+LET较单纯ACLR显著降低移植物断裂率(OR 2.90,95%CI 1.89-4.46);LET股骨固定方式中锚钉固定(OR 4.93,P<.001)和U形钉固定(OR 3.04,P<.001)的移植物失败率降低最明显,硬件取出率低(0.82%)。

要点

  • ACLR+LET较单纯ACLR显著降低移植物断裂率(OR 2.90,95%CI 1.89-4.46)。
  • LET股骨固定方式中锚钉固定(OR 4.93,P<.001)和U形钉固定(OR 3.04,P<.001)的移植物失败率降低最明显。
  • LET专用硬件取出率低(0.82%,95%CI 0.07%-2.10%),U形钉组1.58% vs 锚钉组1.10% vs 纽扣组0% vs 螺钉组0%(P=.702)。

核心结论

  • ACLR+LET较单纯ACLR显著降低原发性移植物失败风险。
  • LET股骨固定方式中锚钉和U形钉固定的ACL移植物失败率最低,硬件取出率相似。

研究设计与样本

  • 系统综述与Meta分析,证据等级3级,按照PRISMA指南在PubMed、Embase、Scopus和CENTRAL中进行全面检索。
  • 共筛选1199项研究,17项符合最终纳入标准,分析2527例接受ACLR的患者,其中1254例接受LET增强。

主要发现

  • LET增强较单纯ACLR显著降低移植物断裂率(OR 2.90,95%CI 1.89-4.46)。
  • ACLR+LET亚组中,锚钉固定移植物失败降低最明显(OR 4.93,P<.001),其次为U形钉固定(OR 3.04,P<.001)。
  • 纽扣、缝线和螺钉等其他固定方式显示潜在获益,但各自结果未达统计学显著(P>.05)。
  • LET显著降低初次ACLR的移植物失败(OR 3.44,P=.00)。
  • LET专用硬件取出率低(0.82%,95%CI 0.07%-2.10%),U形钉组1.58% vs 锚钉组1.10% vs 纽扣组0% vs 螺钉组0%(P=.702)。

关键数值与推荐

  • 检索词涉及Lateral Extra-articular Tenodesis和Modified Lemaire。
  • Meta分析显著性阈值设为.05。
  • 纳入17项研究,2527例ACLR患者,其中1254例接受ACLR+LET。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Anterior cruciate ligament reconstruction augmented with modified-Lemaire lateral extra-articular tenodesis (ACLR+LET) improves rotational stability of the knee in patients with a moderate to high risk of graft failure. Early biomechanical data suggest divergent pullout strengths among various LET fixation methods, but their clinical significance remains to be determined. PURPOSE: To evaluate graft rupture rates in ACLR+LET compared with ACLR alone, stratified by the method of LET femoral fixation. STUDY DESIGN: Systematic review and meta-analysis; Level of evidence, 3. METHODS: A systematic review was conducted in accordance with the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analysis) guidelines. A comprehensive search was conducted across PubMed, Embase, Scopus, and CENTRAL for studies that referenced Lateral Extra-articular Tenodesis and Modified Lemaire. A meta-analysis was performed with a significance threshold of .05. RESULTS: A total of 1199 studies were screened, and 17 met the final inclusion criteria. Across these studies, 2527 patients who underwent ACLR were analyzed; 1254 underwent ACLR with LET augmentation. LET augmentation significantly reduced graft rupture rates compared with ACLR alone (odds ratio [OR], 2.90 [95% CI, 1.89-4.46]). Among ACLR+LET subgroups, anchor fixation demonstrated the greatest reduction in graft failure (OR, 4.93; P < .001), followed by staple fixation (OR, 3.04; P < .001). Other fixation methods-including button, suture, and screw-showed potential benefit, but individual results were not statistically significant (P > .05). Further analysis revealed that LET significantly reduced graft failure in primary ACLR (OR, 3.44; P = .00). LET-specific hardware removal was rare (0.82% [95% CI, 0.07%-2.10%]), with the highest rates seen in staple fixation, followed by anchor, and no events reported in the button and screw groups (1.58% vs 1.10% vs 0% vs 0%; P = .702). CONCLUSION: ACLR+LET significantly reduces the risk of primary graft failure compared with ACLR alone. Among LET femoral fixation methods, anchor and staple fixation demonstrate the lowest ACL graft failure rates, with similar hardware removal rates.

来源:Am J Sports Med,查看原文。版权归原作者所有。

引用

  1. Johnson MC, Tabbaa A, Galina J, et al. The Effect of Lateral Extra-articular Tenodesis Femoral Fixation Methods on Graft Failure Rates in Anterior Cruciate Ligament Reconstruction: A Systematic Review and Meta-analysis. Am J Sports Med. 2026. PMID: 41572954. doi:10.1177/03635465251405495

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。