该回顾性分析纳入2014至2023年接受初次全膝关节置换术的1,243例患者共1,440膝,其中35膝(2.4%)在术中或术后90天内发生假体周围骨折。多因素回归显示股骨假体周围骨折的独立危险因素包括无股骨柄的限制性髁假体衬垫、骨质疏松、股骨前侧切迹及后稳定型股骨假体,胫骨骨折的危险因素是术前膝外翻对线。

要点

  • 无股骨柄的限制性髁假体衬垫与股骨假体周围骨折独立相关(OR 54,95%CI 3.7至1,016,P=0.002)。
  • 骨质疏松(OR 20.5,95%CI 5.4至77.2,P=0.001)和股骨前侧切迹(OR 11.4,95%CI 2.9至44.6,P=0.001)是股骨骨折的独立危险因素。
  • 术前膝外翻对线是胫骨假体周围骨折的危险因素(OR 11,95%CI 2.7至45.9,P=0.001)。

核心结论

  • 术前识别并优化骨质疏松患者、谨慎处理膝外翻畸形、避免股骨前侧切迹以及在使用高限制性衬垫时使用股骨柄,可能有助于降低假体周围骨折风险。

研究设计与样本

  • 回顾性分析纳入2014至2023年间接受初次全膝关节置换术的1,243例患者共1,440膝,其中35膝(2.4%)在术中或术后90天内发生假体周围骨折并构成研究组。

主要发现

  • 骨折组患者年龄更大,平均71±8.8岁,非骨折组平均68±7.6岁(P=0.014)。
  • 多因素回归分析中,股骨假体周围骨折的独立危险因素包括使用无股骨柄的限制性髁假体衬垫(OR 54,95%CI 3.7至1,016,P=0.002)。
  • 骨质疏松(OR 20.5,95%CI 5.4至77.2,P=0.001)、股骨前侧切迹(OR 11.4,95%CI 2.9至44.6,P=0.001)和使用后稳定型股骨假体(OR 6.9,95%CI 1.8至27,P=0.003)也是股骨假体周围骨折的独立危险因素。
  • 对于胫骨骨折,术前膝外翻对线被确定为危险因素(OR 11,95%CI 2.7至45.9,P=0.001)。

临床怎么用

  • 作者认为,术前识别并优化骨质疏松患者、谨慎处理膝外翻畸形、避免股骨前侧切迹以及在使用高限制性衬垫时使用股骨柄,可能有助于降低假体周围骨折风险。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Previous research on periprosthetic fractures (PPFs) following total knee arthroplasty (TKA) has primarily addressed late postoperative complications. Evidence concerning intraoperative and early (≤ 90 days) fractures remains limited, particularly within Eastern European and Middle Eastern populations. This study aimed to evaluate the incidence and identify risk factors for such fractures in a large national cohort. METHODS: A retrospective analysis was conducted on 1,243 patients and 1,440 knees who underwent primary TKA between 2014 and 2023. Fractures developed in 35 knees (2.4%) intraoperatively or within 90 days after surgery and constituted the study group. Patients in the fracture group were older, with a mean age of 71 ± 8.8 years compared with 68 ± 7.6 years in the nonfracture group (P = 0.014). Demographic data, comorbidities, preoperative coronal alignment, and characteristics of the implants were compared between the two groups. Univariate and multivariate regression analyses were performed to determine risk factors based on the location of the fracture. RESULTS: In multivariate regression analyses, independent risk factors for femoral PPF included the use of a constrained condylar insert without a femoral stem (odds ratio (OR): 54, 95% confidence interval (CI): 3.7 to 1,016; P = 0.002), a diagnosis of osteoporosis (OR: 20.5, 95% CI: 5.4 to 77.2; P = 0.001), anterior femoral notching (OR: 11.4, 95% CI: 2.9 to 44.6; P = 0.001), and the use of a posterior-stabilized femoral component (OR: 6.9, 95% CI: 1.8 to 27; P = 0.003). For tibial fractures, preoperative valgus alignment was identified as a risk factor (OR: 11, 95% CI: 2.7 to 45.9; P = 0.001). CONCLUSIONS: Preoperative identification and optimization of osteoporotic patients, careful management of valgus deformities, avoidance of anterior femoral notching, and the use of femoral stems when employing high-constraint inserts may help reduce the risk of PPF.