现代高孔隙度干骺端金属cone在翻修全膝关节置换术中的结局:系统综述与Meta分析
该系统综述与Meta分析纳入63项研究、4,433例患者和5,435个干骺端cone,评估翻修全膝关节置换术中高孔隙度干骺端cone的临床与影像学结局。加权平均随访49.7个月时,全因再翻修率为13.5%,cone取出率为3.6%,影像学骨整合率为96.0%,感染是再翻修最常见原因。钽cone与钛cone、骨水泥固定与混合固定的生存率亚组比较均无显著差异。
要点
- 加权平均随访49.7个月,全因再翻修率13.5%,最常见原因为感染。
- cone取出率3.6%,其中无菌性松动仅占0.7%。
- 影像学骨整合率96.0%;钽与钛cone、骨水泥与混合固定间生存率无显著差异。
核心结论
- 现代干骺端cone在翻修全膝关节置换术中具有高骨整合率和高植入物生存率,不同cone材料和固定策略的结局相当。
- 无菌性松动导致的失败极为罕见,感染是cone翻修的主要原因。
研究设计与样本
- 系统综述与Meta分析,检索PubMed、Scopus和Cochrane数据库自建库至2024年10月1日。
- 纳入报告干骺端cone在翻修全膝关节置换术中临床或影像学结局的随机对照试验和观察性队列研究,最低随访1年。
- 共纳入63项研究,包含4,433例患者和5,435个cone;79.9%的股骨和75.4%的胫骨涉及Anderson骨科研究所2B或3型骨缺损。
- 采用随机效应模型进行汇总分析,并按cone材料和固定类型进行亚组分析。
主要发现
- 汇总膝关节协会评分膝关节评分和功能评分分别为77.4(95%CI 70.6至84.3)和67.5(95%CI 58.4至76.6)。
- 加权平均随访49.7个月时,汇总全因再翻修率为13.5%(95%CI 11.0至16.2),最常见原因为感染。
- cone取出率为3.6%(95%CI 2.2至5.2),其中无菌性松动仅占0.7%。
- 影像学骨整合率为96.0%(95%CI 92.5至98.5)。
- 亚组分析显示钽cone与钛cone的生存率无显著差异(3.7% vs 2.2%,P=0.199),骨水泥固定与混合固定的生存率无显著差异(4.7% vs 1.9%,P=0.274)。
关键数值与推荐
- 纳入标准为报告干骺端cone在翻修全膝关节置换术中临床或影像学结局的随机对照试验和观察性队列研究,最低随访1年。
- 汇总膝关节协会评分膝关节评分为77.4(95%CI 70.6至84.3),功能评分为67.5(95%CI 58.4至76.6)。
- 加权平均随访49.7个月时,全因再翻修率为13.5%(95%CI 11.0至16.2),cone取出率为3.6%(95%CI 2.2至5.2),影像学骨整合率为96.0%(95%CI 92.5至98.5)。
- 钽cone与钛cone的生存率分别为3.7%和2.2%(P=0.199),骨水泥固定与混合固定的生存率分别为4.7%和1.9%(P=0.274)。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Metaphyseal bone loss represents a major challenge in revision total knee arthroplasty (RTKA). Highly porous metaphyseal cones have potential for osseointegration and durable fixation. While early evidence was limited to tantalum cones, newer designs, such as three-dimensional-printed titanium cones, have been introduced by multiple manufacturers, necessitating an updated synthesis of the literature. METHODS: PubMed, Scopus, and Cochrane databases were searched from inception through October 1, 2024. Eligible studies included randomized controlled trials and observational cohorts reporting clinical or radiological outcomes of metaphyseal cones in RTKA with a minimum 1-year follow-up. Demographics, implant characteristics, functional scores, survivorship, cone removal rates, and radiographic outcomes were recorded. Pooled analyses were performed using random-effects models, with subgroup analyses by cone material and fixation type. There were 63 studies comprising 4,433 patients and 5,435 cones that were included, with 79.9% of femora and 75.4% of tibiae involving Anderson Orthopedic Research Institute type 2B or 3 defects. RESULTS: Significant improvements in function were observed, with pooled Knee Society Score Knee and Function scores of 77.4 (95% confidence interval [CI], 70.6 to 84.3) and 67.5 (95% CI, 58.4 to 76.6), respectively. The pooled all-cause re-revision rate at a weighted mean follow-up of 49.7 months was 13.5% (95% CI, 11.0 to 16.2), most commonly due to infection, whereas cone removal occurred in 3.6% (95% CI, 2.2 to 5.2), with aseptic loosening accounting for only 0.7%. Radiographic osseointegration was achieved in 96.0% (95% CI, 92.5 to 98.5). Subgroup analyses demonstrated no significant difference in survivorship between tantalum versus titanium cones (3.7 versus 2.2%, P = 0.199) and cemented versus hybrid fixation (4.7 versus 1.9%, P = 0.274). CONCLUSIONS: Modern metaphyseal cones have high osseointegration rates and implant survivorship in RTKA, with comparable outcomes noted across different cone materials and fixation strategies. Failure due to aseptic loosening is exceedingly rare, with infection being the predominant cause of cone revision.
引用
- Goh GS, Lee S, Singh K, et al. Contemporary Outcomes of Highly Porous Metaphyseal Cones in Revision Total Knee Arthroplasty: A Systematic Review and Meta-Analysis. J Arthroplasty. 2026. PMID: 41513075. doi:10.1016/j.arth.2026.01.006
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。