文献速递运动医学关节外科

人工智能驱动的CT-MRI图像融合与分割用于前交叉韧带重建自动术前规划:开发与应用

AI-Driven CT-MRI Image Fusion and Segmentation for Automatic Preoperative Planning of ACL Reconstruction: Development and Application.
PubMed 文献 · J Bone Joint Surg Am · 2025-12-09

本研究开发了基于深度学习的CT-MRI融合与分割自动术前规划系统,用于前交叉韧带重建,并在200例膝关节影像、36例骨模型和36例临床手术(另36例常规手术对照)中验证。系统分割Dice系数为0.864,每例规划耗时192±90.2秒,骨模型验证中规划与执行值平均偏差小于1mm(均p>0.05),临床测试中AI指导组在D-S、H-L、M-L、A-P方向上偏离理想点的程度均显著小于常规组(均p<0.05)。

要点

  • CT-MRI融合生成个体化3D模型,分割Dice系数为0.864,每例AI规划耗时192±90.2秒。
  • 骨模型验证中股骨与胫骨隧道长度及隧道间移植物长度的规划与执行值平均偏差均小于1mm(均p>0.05)。
  • 临床测试中AI指导组在D-S、H-L、M-L、A-P方向偏离理想点均显著小于常规组(均p<0.05)。

核心结论

  • AI驱动的CT-MRI融合图像分割与自动术前规划能够自动、精确、可重复地生成接近理想的隧道出入口规划,具有等距、解剖和个体化特征;作者认为该技术有望降低并发症和翻修率并改善术后功能。

研究设计与样本

  • 研究纳入200例前交叉韧带完整膝关节的CT和MRI图像进行手动标注,采用Dual-UNet配准架构融合并动态3D重建;在36例骨模型重建中验证AI规划准确性;在36例使用AI规划衍生的3D打印患者特异性导板手术患者与36例常规手术对照中测试临床可行性。

主要发现

  • CT-MRI图像融合生成高分割精度的个体化3D模型,Dice系数=0.864。
  • AI规划每例耗时192±90.2秒。
  • 骨模型验证中股骨隧道长度、胫骨隧道长度及隧道间移植物长度的规划值与执行值平均偏差均<1mm(均p>0.05)。
  • 临床测试中AI指导组在D-S、H-L、M-L和A-P方向偏离理想点的程度均显著小于常规组(均p<0.05)。

关键数值与推荐

  • 自动规划标准包括接近理想点、覆盖解剖足印区以及等距长度变化<2mm。

临床怎么用

  • 作者认为该技术有望用于前交叉韧带重建,包括降低并发症和翻修率并改善术后功能。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The goals of this study were to develop an artificial intelligence (AI)-driven automated preoperative planning system for anterior cruciate ligament (ACL) reconstruction by integrating deep learning with computed tomography (CT)-magnetic resonance imaging (MRI) image fusion and segmentation, and to evaluate its accuracy. METHODS: Structures on CT and MRI scans of 200 knee joints from patients with an intact ACL (aged 18 to 50 years, 81.0% male, all ethnic Chinese) were manually annotated. Fusion of the CT and MRI images was performed using a Dual-UNet registration architecture incorporating multiscale information fusion, enabling dynamic 3D reconstruction of the fused images for ACL insertion site identification and isometry assessment. A deep-learning framework was trained to analyze the fused image to precisely optimize ACL tunnel positioning, including identifying the entrances and exits of the femoral and tibial tunnels. Criteria in the automated planning included proximity to the ideal point, coverage of the anatomical footprint area, and isometric length variation of <2 mm. The accuracy of the AI system was then validated in 36 ACL reconstructions performed in bone models by comparing the drilled femoral and tibial tunnel lengths and graft length between the tunnels with the planned values. Finally, clinical feasibility was tested in 36 patients undergoing ACL reconstruction surgery using 3D-printed patient-specific guides derived from the AI planning, with 36 conventional surgeries as controls. Deviation of tunnel positions from the planned positions was compared between the 2 groups. RESULTS: CT-MRI image fusion was able to generate an individualized 3D model with high segmentation accuracy (Dice coefficient = 0.864). The AI planning required 192 ± 90.2 seconds per case. In the bone model validation, the mean deviation between the planned and executed values was <1 mm for the femoral and tibial tunnel lengths and graft length between the tunnels (all p > 0.05). In the clinical testing, the AI-guided group demonstrated significantly smaller deviations from the ideal point compared with the conventional group in the deep-to-shallow (D-S), high-to-low (H-L), medial-to-lateral (M-L), and anterior-to-posterior (A-P) directions (all p < 0.05). CONCLUSIONS: The AI-driven segmentation of CT-MRI fusion images and automatic preoperative ACL reconstruction planning demonstrated the capability to automatically, precisely, and reproducibly generate plans for nearly ideal tunnel entry and exit points with isometric, anatomical, and individualization characteristics. This technology is expected to hold clinical potential for ACL reconstruction, including reduced complication and revision rates and enhanced postoperative function.

来源:J Bone Joint Surg Am,查看原文。版权归原作者所有。

引用

  1. Yu H, Dong J, Wang L, et al. AI-Driven CT-MRI Image Fusion and Segmentation for Automatic Preoperative Planning of ACL Reconstruction: Development and Application. J Bone Joint Surg Am. 2025. PMID: 41364772. doi:10.2106/JBJS.25.00485

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。