预测全髋关节置换术中髋臼固定失败与骨丢失:计算机模拟与体外实验相结合的方法

Predicting Acetabular Fixation Failure and Bone Loss in Total Hip Arthroplasty: A Combined In Silico and In Vitro Approach.
PubMed 文献 · J Arthroplasty · 2025-12-13

本研究采用有限元模拟与体外复合骨应变测量相结合的方法,模拟全髋关节置换术后髋臼周围骨丢失与假体稳定性。结果显示模拟与实验模型皮层应变高度一致(R2=0.91),髋臼植入使后方皮层骨应变减少约60%、前方减少约80%,进行性骨丢失导致假体迁移达1.21 mm。作者认为需重新考虑髋臼概念设计以提高长期生存率。

要点

  • 有限元与体外模型皮层应变测量高度一致(R2=0.91)。
  • 髋臼植入使后方皮层骨应变减少约60%、前方减少约80%。
  • 进行性骨丢失使假体迁移达1.21 mm,以后上区域最明显。

核心结论

  • 骨丢失模拟有效展示了髋臼组件引起的应变屏蔽效应,结果与临床观察一致,作者认为需重新考虑髋臼概念设计以提高长期生存率并降低松动风险。

研究设计与样本

  • 研究采用计算机模拟(有限元法,FEM)与体外实验相结合的方法,FEM模型包含股骨、髂骨及假体(髋臼杯、聚乙烯内衬和股骨柄)的解剖真实几何形状。
  • 体外模型使用安装应变片的复合骨测量皮层应变,骨丢失与髋臼松动按四个渐进步骤模拟,并通过顺序计算机控制制造在体外装置中重现以评估假体稳定性,加载条件重现步态时髋关节受力。

主要发现

  • 皮层应变测量显示计算机模拟与实验模型高度一致(R2=0.91)。
  • 髋臼植入使后方皮层骨应变减少约60%、前方减少约80%。
  • 骨丢失在后上区域及假体-骨界面邻近皮层区域最明显,体积为90 mm3。
  • 进行性骨丢失降低假体稳定性,最终导致组件迁移达1.21 mm,并增加髋臼杯与髋臼腔内骨小梁的接触。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Total hip arthroplasty continues to rise in prevalence in both the United States and Europe. The leading cause of revision surgery remains acetabular failure, primarily associated with instability and peri-implant bone loss. This study aimed to investigate bone loss around acetabular components following total hip arthroplasty. METHODS: A combined in silico (finite element method, FEM) and in vitro approach was employed to predict short- to mid-term bone loss and assess acetabular implant stability. The FEM model incorporated anatomically realistic geometries of the femur, ilium, and implants (acetabular shell, polyethylene liner, and stem). The in vitro model utilized composite bones instrumented with strain gauges to measure cortical strains. Bone loss and acetabular loosening were simulated in four progressive steps, guided by FEM strain analysis, and reproduced through sequential computer-controlled manufacturing in the in vitro setup to evaluate implant stability. Loading conditions reproduced hip joint forces during gait. RESULTS: Cortical strain measurements demonstrated strong agreement between the in silico and experimental models (R2 = 0.91). Acetabular implantation reduced cortical bone strains by approximately 60% posteriorly and 80% anteriorly. Bone loss was most pronounced in the posterior-superior region and at cortical areas adjacent to the implant-bone interface and represents a volume of 90 mm3. Progressive bone loss reduced implant stability, ultimately leading to component migration up to 1.21 mm and increased contact between the acetabular shell and trabecular bone within the acetabular cavity. CONCLUSIONS: The bone loss simulation effectively demonstrated strain-shielding effects induced by acetabular components. These results, consistent with clinical observations, highlight the need to reconsider acetabular concept design to improve long-term survival rates and reduce the risk of loosening.

来源:J Arthroplasty,查看原文。版权归原作者所有。