文献速递关节外科

陶瓷对陶瓷全髋关节置换术中股骨柄切迹的患病率、进展及临床影响:至少15年随访研究

Prevalence, Progression, and Clinical Impact of Stem Notching in Ceramic-on-Ceramic Total Hip Arthroplasty: A Minimum 15-Year Follow-Up Study.
PubMed 文献 · J Arthroplasty · 2025-12-17

该回顾性队列分析纳入1997年11月至2003年12月接受陶瓷对陶瓷全髋关节置换术且随访至少15年的患者,21.5%(63/293)存在股骨柄切迹。切迹深度在发现后5年以上未见有意义的进展,切迹组与非切迹组陶瓷组件骨折率(6.3% vs 4.3%,P=0.509)、噪音发生率(25.4% vs 22.6%,P=0.618)及改良Harris髋关节评分(89.3 vs 91.2,P=0.103)均无显著差异。

要点

  • 陶瓷对陶瓷全髋关节置换术中股骨柄切迹发生率为21.5%(63/293)。
  • 切迹深度在发现后5年以上未见有意义的进展。
  • 切迹组与非切迹组陶瓷相关并发症及功能评分均无显著差异。

核心结论

  • 陶瓷对陶瓷全髋关节置换术中股骨柄切迹是相对常见但常被忽视的现象,大多数切迹随时间保持稳定且与较差的功能结果无关。
  • 尽管有切迹的髋关节陶瓷相关噪音和股骨头骨折发生率更高,但差异无统计学意义。
  • 临床医生应认识这一发现,维持常规随访,并向患者保证单纯切迹不会造成任何即刻问题。

研究设计与样本

  • 回顾性队列分析,纳入1997年11月至2003年12月期间接受陶瓷对陶瓷全髋关节置换术的患者,随访至少15年。
  • 通过影像学评估诊断股骨柄切迹,293例中63例(21.5%)存在切迹。
  • 切迹病变平均监测12.5年(范围1至23.2年)。
  • 主要终点为切迹深度变化及陶瓷相关并发症(陶瓷组件骨折和噪音产生);次要结局为改良Harris髋关节评分功能评估。
  • 证据等级为III级,回顾性治疗研究。

主要发现

  • 切迹深度在发现后5年以上未见有意义的进展。
  • 较低的髋臼杯外倾角和较高的前倾角与切迹存在相关。
  • 陶瓷组件骨折发生率在切迹组为6.3%,非切迹组为4.3%(P=0.509)。
  • 噪音在切迹组为25.4%,非切迹组为22.6%(P=0.618)。
  • 改良Harris髋关节评分均值切迹组为89.3,非切迹组为91.2(P=0.103)。

关键数值与推荐

  • 股骨柄切迹诊断采用影像学评估。
  • 切迹发生率为21.5%(63/293)。
  • 陶瓷组件骨折率切迹组6.3% vs 非切迹组4.3%(P=0.509)。
  • 噪音发生率切迹组25.4% vs 非切迹组22.6%(P=0.618)。
  • 改良Harris髋关节评分均值切迹组89.3 vs 非切迹组91.2(P=0.103)。

临床怎么用

  • 临床医生应认识股骨柄切迹这一发现,维持常规随访,并向患者保证单纯切迹不会造成任何即刻问题(作者建议)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Stem notching, resulting from impingement between the femoral stem and ceramic liner in ceramic-on-ceramic (CoC) total hip arthroplasty (THA), has been linked to adverse outcomes such as ceramic-related noise and ceramic component fractures. Despite its potential significance, its true incidence is infrequently documented, and the long-term clinical impact remains uncertain. This study aimed to assess the minimum 15-year outcomes and complications associated with stem notching in CoC THA. METHODS: We performed a retrospective cohort analysis of patients who received CoC THA between November 1997 and December 2003, with a minimum follow-up period of 15 years. Stem notching was diagnosed using radiographic evaluation and was observed in 21.5% of cases (63 of 293). The lesions were monitored for an average of 12.5 years from detection (range, one to 23.2). The primary endpoints included changes in notch depth and the occurrence of ceramic-related complications such as ceramic component fractures and noise generation. The secondary outcomes involved functional evaluation via the modified Harris Hip Score. RESULTS: Notch depth did not demonstrate meaningful progression beyond five years after identification. Lower cup inclination and higher anteversion were associated with the presence of notching. The incidence of ceramic component fractures was 6.3% in notched hips compared to 4.3% in hips without notches (P = 0.509), while noise was noted in 25.4% of notched hips and 22.6% of non-notched hips (P = 0.618). Functional assessment revealed similar outcomes between those who did and did not have notches (mean modified Harris Hip Score: 89.3 versus 91.2; P = 0.103). CONCLUSIONS: Stem notching in CoC THA is a relatively common, but often overlooked phenomenon. Most notches remained stable over time and were not associated with inferior functional outcomes. Although hips with notches showed a higher rate of ceramic-related noise and head fractures, these differences were not statistically significant. Clinicians should recognize this finding, maintain routine follow-up, and reassure patients that a notch alone does not pose any immediate problem. LEVEL OF EVIDENCE: Level III, retrospective therapeutic study.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Kang SY, Loh LL, Jeon YJ, et al. Prevalence, Progression, and Clinical Impact of Stem Notching in Ceramic-on-Ceramic Total Hip Arthroplasty: A Minimum 15-Year Follow-Up Study. J Arthroplasty. 2025. PMID: 41419031. doi:10.1016/j.arth.2025.12.021

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。