文献速递关节外科

在全膝关节置换术中关节腔内联合使用氨甲环酸与万古霉素的浓度、抗菌效果与安全性:一项随机研究

Concentration, Antibacterial Effect, and Safety of Combining Intra-articular Epsilon-Aminocaproic Acid and Vancomycin in Primary Total Knee Arthroplasty: A Randomized Study.
PubMed 文献 · J Arthroplasty · 2025-12-18

本研究将94例单侧初次全膝关节置换术患者随机分为万古霉素联合ε-氨基己酸(VE)组和万古霉素(V)组,并倾向性评分匹配47例历史全膝关节置换术形成EACA(E)组。VE组关节腔内万古霉素浓度在8小时和24小时高于V组,而血清浓度相似;VE组围手术期失血量与E组相当且显著低于V组(P<0.01)。联合用药维持了万古霉素浓度且未损害EACA的抗纤溶功能,但未增强万古霉素的抗菌效果,无急性肾损伤、耳毒性或过敏反应发生。

要点

  • VE组关节腔内万古霉素浓度在8小时和24小时均高于V组,而两组血清浓度相似。
  • VE组围手术期失血量与E组相当,且显著低于V组(P<0.01)。
  • VE组与V组抗菌效果相当,均优于E组;无急性肾损伤、耳毒性或过敏反应。

核心结论

  • 关节腔内联合使用万古霉素与EACA可维持万古霉素浓度且不损害EACA的抗纤溶功能,但未增强万古霉素的抗菌效果。

研究设计与样本

  • 随机对照研究:94例单侧初次全膝关节置换术患者随机分为VE组(万古霉素1000 mg/30 mL联合EACA 20 mL)和V组(万古霉素联合生理盐水),另倾向性评分匹配47例历史全膝关节置换术形成E组(生理盐水联合EACA)。

主要发现

  • VE组围手术期失血量与E组相当,且显著低于V组(P<0.01)。
  • VE组关节腔内万古霉素浓度在8小时和24小时高于V组,而血清浓度相似。
  • VE组与V组抗菌效果相当,均优于E组。
  • 无急性肾损伤、耳毒性或过敏反应病例。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: In this study, we aimed to investigate the intra-articular concentration, antibacterial effect, and safety of a combination of vancomycin and epsilon-aminocaproic acid (EACA) in primary total knee arthroplasty (TKA). METHODS: There were 94 patients who underwent unilateral primary TKA and were randomized into the vancomycin plus EACA (VE) group and the vancomycin (V) group. There were 47 contemporary TKAs propensity score-matched to form the EACA (E) group. The VE group received vancomycin 30 mL (1,000 mg) plus EACA 20 mL, the V group received vancomycin plus saline, and the E group received saline plus EACA. Postoperative blood and drainage samples were collected for vancomycin analysis using liquid chromatography-tandem mass spectrometry. Perioperative blood loss, renal function, and bacterial tests for common periprosthetic joint infection pathogens were evaluated. RESULTS: Perioperative blood loss in the VE group was equivalent to that in the E group and significantly lower than that in the V group (P < 0.01). The intra-articular vancomycin levels in the VE group were higher than those in the V group at eight and 24 hours, while the serum levels were similar. Antimicrobial effects were comparable in the VE and the V groups, both of which were superior to those in the E group. There were no cases of acute renal injury, ototoxicity, or anaphylaxis. CONCLUSIONS: The combination of intra-articular vancomycin and EACA maintained the vancomycin concentration without impairing the antifibrinolytic function of EACA, although it did not enhance the antibacterial effect of vancomycin.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Zhang Y, Wei J, Su C, et al. Concentration, Antibacterial Effect, and Safety of Combining Intra-articular Epsilon-Aminocaproic Acid and Vancomycin in Primary Total Knee Arthroplasty: A Randomized Study. J Arthroplasty. 2025. PMID: 41421712. doi:10.1016/j.arth.2025.12.032

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。