引流窦道与假体周围关节感染:传统滑液细胞计数可能造成误导
该回顾性研究纳入611例因假体周围关节感染(PJI)治疗的全关节置换术,其中191例符合2011年MSIS主要标准且实验室评估前两周未用抗生素,分为有窦道组(58例)与无窦道组(133例)。有窦道组早期和晚期PJI的滑液中位白细胞计数均显著低于无窦道组,且滑液白细胞和血清CRP的假阴性率显著更高。作者结论认为窦道存在本身即可诊断PJI,实验室数值相对较低不应使临床医生质疑该诊断。
要点
- 有窦道组早期PJI滑液中位白细胞计数为9,978 cells/μL,显著低于无窦道组的76,068 cells/μL(P=0.01)。
- 有窦道组晚期PJI滑液中位白细胞计数为20,365 cells/μL,显著低于无窦道组的63,356 cells/μL(P=0.03)。
- 有窦道组滑液白细胞检测PJI的假阴性率为38%,显著高于无窦道组的6%(P=0.02);血清CRP假阴性率为48%,显著高于无窦道组的15%(P<0.0001)。
核心结论
- 有窦道患者通过滑液白细胞检测PJI的假阴性率约为无窦道患者的六倍,通过血清CRP检测的假阴性率约为三倍。
- 窦道存在即可诊断PJI,实验室检查数值相对较低不应使临床医生质疑该诊断。
研究设计与样本
- 回顾性综述,纳入2000年至2020年在一家高容量学术中心因PJI治疗的611例初次全关节置换术。
- 仅纳入191例(94髋、97膝)符合2011年MSIS主要标准且实验室评估前两周内未使用抗生素的患者。
- 分为有窦道组(n=58)和无窦道组(n=133),分别分析早期(术后不足90天)和晚期(术后≥90天)PJI的实验室数值。
- 基于2018年ICM各诊断试验的截断值比较PJI检测的假阴性率。
- 证据等级:Level IV——回顾性综述。
主要发现
- 有窦道组早期PJI滑液中位白细胞计数为9,978 cells/μL,无窦道组为76,068 cells/μL,有窦道组显著更低(P=0.01)。
- 有窦道组晚期PJI滑液中位白细胞计数为20,365 cells/μL,无窦道组为63,356 cells/μL,有窦道组显著更低(P=0.03)。
- 有窦道组滑液白细胞检测PJI的假阴性率为38%,无窦道组为6%,有窦道组显著更高(P=0.02)。
- 有窦道组血清CRP检测PJI的假阴性率为48%,无窦道组为15%,有窦道组显著更高(P<0.0001)。
关键数值与推荐
- 以2011年MSIS主要标准定义PJI。
- 以2018年ICM截断值定义各诊断试验的假阴性。
- 有窦道组滑液白细胞假阴性率为38%,无窦道组为6%(P=0.02)。
- 有窦道组血清CRP假阴性率为48%,无窦道组为15%(P<0.0001)。
临床怎么用
- 作者认为,窦道存在即可诊断PJI,实验室检查数值相对较低不应使临床医生质疑该诊断。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Serologic and synovial laboratory values guiding the diagnosis of periprosthetic joint infection (PJI) are well-established. We hypothesized that these values would be lower in patients who had a draining sinus tract. The purpose of this study was to determine if patients who had sinus tracts had lower values for serum erythrocyte sedimentation rate (ESR), serum C-reactive protein (CRP), synovial white blood cell (WBC) count, and synovial percent neutrophils. METHODS: We retrospectively reviewed 611 primary total joint arthroplasties treated for PJI between 2000 and 2020 at a high-volume academic center. Only 191 patients (94 hips, 97 knees) who met the 2011 Musculoskeletal Infection Society (MSIS) major criteria for PJI and did not receive antibiotics within two weeks before laboratory evaluation were included. Patients were divided into those who had sinus tracts (n = 58) and those who did not (n = 133). Laboratory values for early (less than 90 days) and late (≥ 90 days) postoperative PJI cases were analyzed separately. False negative rates for detecting PJI were compared based on the 2018 International Consensus Meeting (ICM) cutoffs for each diagnostic test. RESULTS: Median synovial WBC count was significantly lower in early (9,978 versus 76,068 cells/μL; P = 0.01) and late (20,365 versus 63,356 cells/μL; P = 0.03) PJI in those who had a sinus tract. False negative rates for detecting PJI were significantly higher in patients who had a sinus tract compared to those who did not for synovial WBC (38 versus 6%; P = 0.02) and serum CRP (48 versus 15%; P < 0.0001). CONCLUSIONS: Those who had a sinus tract had an approximately six times higher false negative rate for detecting PJI by synovial WBC. The false negative rate for detecting PJI by serum CRP was approximately three times higher in those who had a sinus tract. The presence of a sinus tract is diagnostic of PJI, and relatively lower laboratory values on workup should not lead clinicians to question this diagnosis. LEVEL OF EVIDENCE: Level IV - retrospective review.
引用
- Alder KD, Dugdale EM, Osmon DR, et al. Draining Sinus Tracts and Periprosthetic Joint Infections: Traditional Synovial Fluid Counts May Be Misleading. J Arthroplasty. 2025. PMID: 41386530. doi:10.1016/j.arth.2025.12.004
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。