文献速递关节外科

保留股骨柄的翻修全髋关节置换术中钛套筒新陶瓷头使用与平均八年随访时股骨头颈交界失败是否相关

Is the Use of New Ceramic Heads With Titanium Sleeves on Retained Femoral Stems in Revision Total Hip Arthroplasty Associated With Femoral Head or Neck Junction Failure at Mean Eight-Year Follow-Up?
PubMed 文献 · J Arthroplasty · 2025-11-27

本研究纳入2011至2022年本机构连续316例(295例患者)无菌性翻修全髋关节置换术,均使用保留股骨柄上的钛套筒新陶瓷头,平均随访7.7年。结果显示无因头颈交界失败而行再翻修者,5年和10年全因再翻修无生存率分别为81.1%和77.0%,髋臼组件保留(P=0.027)和因不稳定行翻修(P=0.042)是全因再翻修的危险因素。

要点

  • 保留股骨柄上使用钛套筒新陶瓷头在平均8年随访中无头颈交界失败。
  • 5年和10年全因再翻修无生存率分别为81.1%和77.0%。
  • 髋臼组件保留(P=0.027)和因不稳定行翻修(P=0.042)与全因再翻修相关。

核心结论

  • 保留股骨柄上使用钛套筒新陶瓷头在平均8年随访中是安全的,无头颈交界失败。
  • 髋臼组件保留和因不稳定行翻修是全因再翻修的危险因素。

研究设计与样本

  • 回顾性纳入2011年至2022年本机构所有连续无菌性翻修全髋关节置换术,使用保留股骨柄上的钛套筒新陶瓷头,共316例翻修(295例患者),平均随访7.7年(范围2.1至14.3年),平均年龄65岁,57%为女性。
  • 采用Kaplan-Meier分析确定生存率,并计划使用多因素逻辑回归识别头颈交界失败和全因再翻修的危险因素。

主要发现

  • 无因头颈交界失败而行再翻修者。
  • 66髋(21%)在平均1.8年时行再翻修,最常见原因为不稳定(66例中39例)、感染(66例中17例)和无菌性松动(66例中8例)。
  • 5年和10年全因再翻修无生存率分别为81.1%和77.0%。
  • 无植入物或手术因素与头颈交界失败相关。
  • 多因素分析确定髋臼组件保留(P=0.027)和因不稳定行翻修(P=0.042)为再翻修的危险因素。

关键数值与推荐

  • 翻修全髋关节置换术的主要指征为不良局部组织反应(46%)、不稳定(29%)和髋臼无菌性松动(12%)。
  • 38%的翻修行孤立模块组件更换。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Ceramic heads used in revision total hip arthroplasty (rTHA) typically utilize a titanium sleeve adapter to prevent damage by the retained stem taper; however, there is sparse mid-to long-term data on this practice, and risk factors for failure remain relatively unknown. This study aimed to determine revision-free survival, specifically for failure of the head and/or neck junction (HNJ) and all-cause re-revision in this patient population, and to identify factors associated with failure. METHODS: We identified all consecutive aseptic rTHA that used a new ceramic head with a titanium sleeve on a retained stem at our institution between 2011 and 2022. A total of 316 rTHA (295 patients) were included with a mean follow-up of 7.7 years (range, 2.1 to 14.3). The mean age was 65 years, and 57% were women. The main indications for rTHA were adverse local tissue reaction (46%), instability (29%), and acetabular aseptic loosening (12%). Isolated modular component exchange was performed in 38% of revisions. Kaplan-Meier analysis was used to determine survivorship. We aimed to use multivariate logistic regressions to identify risk factors for HNJ failure and all-cause rerevision. RESULTS: There were no rerevisions for HNJ failure. There were 66 hips (21%) that underwent rerevision at a mean of 1.8 years, most commonly for instability (39 of 66), infection (17 of 66), and aseptic loosening (eight of 66). The 5- and 10-years all-cause rerevision-free survival was 81.1 and 77.0%, respectively. There were no implant or surgical factors associated with HNJ failure. Multivariate analyses identified acetabular component retention (P = 0.027) and rTHA for instability (P = 0.042) as risk factors for rerevision. CONCLUSIONS: New ceramic heads with titanium sleeves on retained stems are safe at a mean 8-year follow-up with no HNJ failures. Acetabular component retention and revision for instability were risk factors for all-cause rerevision.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Seah MKT, Howard LC, Horwood NJ, et al. Is the Use of New Ceramic Heads With Titanium Sleeves on Retained Femoral Stems in Revision Total Hip Arthroplasty Associated With Femoral Head or Neck Junction Failure at Mean Eight-Year Follow-Up? J Arthroplasty. 2025. PMID: 41318036. doi:10.1016/j.arth.2025.11.058

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。