含抗氧化剂的高交联聚乙烯可能降低全膝关节置换术的翻修风险:一项美国队列研究
该队列研究基于Kaiser Permanente全关节置换登记系统,纳入2001至2023年因骨关节炎行初次固定平台全膝关节置换术并行髌骨表面置换的成年患者,比较含与不含抗氧化剂的高交联聚乙烯假体的翻修风险。最终样本923例中,含抗氧化剂组48846例,不含抗氧化剂组44077例;调整混杂因素后,含抗氧化剂组全因翻修风险较低(HR 0.86,95%CI 0.79-0.95),无菌性翻修(HR 0.86,95%CI 0.76-0.97)和磨损翻修(HR 0.41,95%CI 0.21-0.81)风险也较低。
要点
- 含抗氧化剂高交联聚乙烯组13年粗翻修发生率为3.4%,不含抗氧化剂组为4.2%。
- 调整混杂因素后,含抗氧化剂组全因翻修风险低于不含抗氧化剂组(HR 0.86,95%CI 0.79-0.95)。
- 含抗氧化剂组磨损翻修风险低于不含抗氧化剂组(HR 0.41,95%CI 0.21-0.81)。
核心结论
- 在接受含抗氧化剂高交联聚乙烯假体全膝关节置换术的病例中,观察到较低的全因翻修风险和较低的磨损特异性翻修风险。
研究设计与样本
- 基于Kaiser Permanente医疗系统全关节置换登记系统的队列研究。
- 纳入2001至2023年因骨关节炎行初次固定平台全膝关节置换术并行髌骨表面置换的成年患者。
- 比较含抗氧化剂与不含抗氧化剂的高交联聚乙烯假体全膝关节置换术病例。
- 最终样本923例:含抗氧化剂组48846例,不含抗氧化剂组44077例。
- 采用多变量Cox比例风险回归评估治疗组翻修风险,并调整协变量。
主要发现
- 患者平均年龄67.7岁,平均体重指数31.2 kg/m²。
- 大多数患者为女性(64.3%)和白人(64.8%),美国麻醉医师协会分级1至2级者占65.2%。
- 含抗氧化剂组13年粗翻修发生率为3.4%,不含抗氧化剂组为4.2%。
- 调整混杂因素后,含抗氧化剂组全因翻修风险低于不含抗氧化剂组(HR 0.86,95%CI 0.79-0.95)。
- 含抗氧化剂组无菌性翻修风险(HR 0.86,95%CI 0.76-0.97)和磨损翻修风险(HR 0.41,95%CI 0.21-0.81)均低于不含抗氧化剂组。
关键数值与推荐
- 主要结局为全因翻修;次要结局为感染性翻修、任何无菌性翻修、磨损翻修和松动翻修。
- 含抗氧化剂组对比不含抗氧化剂组的全因翻修HR为0.86(95%CI 0.79-0.95)。
- 含抗氧化剂组对比不含抗氧化剂组的无菌性翻修HR为0.86(95%CI 0.76-0.97)。
- 含抗氧化剂组对比不含抗氧化剂组的磨损翻修HR为0.41(95%CI 0.21-0.81)。
- 证据等级为治疗性III级。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Although the use of highly cross-linked polyethylene (HXLPE) with antioxidants in total knee arthroplasty (TKA) has increased over time, evidence of any benefit in survivorship over HXLPE without antioxidants is lacking. We sought to compare the TKA revision risk for HXLPE with and without antioxidants. METHODS: Data from the Kaiser Permanente health-care system's total joint replacement registry were used for a cohort study. Adult patients who underwent primary fixed-bearing TKA with patellar resurfacing for osteoarthritis from 2001 to 2023 were included. The study groups were cases of TKA performed with HXLPE with and without antioxidants. The primary outcome was all-cause revision; revisions for septic reasons, any aseptic reasons, wear, and loosening were secondary outcomes. Multivariable Cox proportional-hazards regression was used to evaluate the revision risk by treatment group with an adjustment for covariates. RESULTS: The final study sample included 92,923 TKA cases: 48,846 performed with HXLPE implants with antioxidants and 44,077 performed with HXLPE implants without antioxidants. The mean patient age was 67.7 years, and the mean patient body mass index was 31.2 kg/m 2 . Most patients were female (64.3%) and White (64.8%) and had an American Society of Anesthesiologists classification of 1 to 2 (65.2%). The 13-year crude revision incidence was 3.4% for the antioxidant group and 4.2% for the group without antioxidants. After we adjusted for confounders, we observed a lower revision risk for the antioxidant group compared with the group without antioxidants (hazard ratio [HR], 0.86 [95% confidence interval (CI), 0.79 to 0.95]). When we investigated revisions for specific reasons, we observed a lower risk for aseptic revision (HR, 0.86 [95% CI, 0.76 to 0.97]) and for wear (HR, 0.41 [95% CI, 0.21 to 0.81]) in the antioxidant group. CONCLUSIONS: We observed a lower risk of al-cause revision and a lower risk of revision specifically for wear in TKA cases performed with HXLPE with antioxidants added. LEVEL OF EVIDENCE: Therapeutic Level III . See Instructions for Authors for a complete description of levels of evidence.
引用
- Prentice HA, Chan PH, Chang RN, et al. Antioxidant-Loaded Highly Cross-Linked Polyethylene May Reduce Revision Risk in Total Knee Arthroplasty: A U.S.-Based Cohort Study. J Bone Joint Surg Am. 2025. PMID: 41296832. doi:10.2106/JBJS.25.00490
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。