文献速递关节外科创伤骨科

非骨水泥钛纤维网杯在翻修全髋关节置换术中用于严重髋臼缺损的杯笼复合体

Cementless Titanium Fibermesh Cup in Cup-Cage Construct for Severe Acetabular Defect in Revision Total Hip Arthroplasty.
PubMed 文献 · J Arthroplasty · 2025-11-06

回顾性单中心研究纳入29例Paprosky 3A或3B型髋臼骨缺损患者,2011至2019年行非骨水泥钛纤维网杯的杯笼复合体翻修,随访至少5年。2年假体生存率97%,5年和10年均为90%,所有病例均见植骨融合与骨整合,功能评分显著改善,无因无菌性松动翻修。作者认为钛纤维网杯杯笼复合体是钽杯的可行且经济替代方案。

要点

  • 非骨水泥钛纤维网杯杯笼复合体翻修严重髋臼缺损,5年和10年假体生存率均为90%。
  • 29例全部实现植骨融合与骨整合,骨盆不连续者内侧壁恢复,髋关节中心有效恢复。
  • 功能评分显著改善,无因无菌性松动翻修,作者认为疗效可能源于杯笼复合体概念而非钽杯本身。

核心结论

  • 作者认为非骨水泥钛纤维网杯杯笼复合体是翻修全髋关节置换术中钽杯杯笼复合体的可行且经济替代方案。
  • 作者认为杯笼复合体的成功可能归因于其基本概念而非钽杯的具体使用。

研究设计与样本

  • 回顾性单中心研究,纳入2011至2019年因Paprosky 3A或3B型髋臼骨缺损行非骨水泥钛纤维网杯杯笼复合体翻修的患者29例,随访至少5年。
  • 患者平均年龄63岁(范围41至82岁),平均随访125.7个月(范围76至163个月)。
  • 采用Kaplan-Meier分析评估假体生存率,评估临床结局并连续影像学评估骨修复过程。
  • 证据等级为IV级,治疗性研究。

主要发现

  • 假体累积生存率2年为97%(95%CI 78至100),5年和10年均为90%(95%CI 71至98)。
  • 影像学上29例全部(29/29)显示植骨融合与骨整合,骨盆不连续病例见内侧髋臼壁恢复,髋关节中心有效恢复。
  • 术后功能评分显著改善:Harris髋关节评分术前47.3 vs 术后75.8,Oxford髋关节评分术前21.0 vs 术后37.8,Euro生活质量5维度指数术前0.49 vs 术后0.82,P < 0.001。
  • 研究期间无因无菌性松动需翻修。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Addressing bony defects in cases of severe acetabular bone loss remains challenging, and the cup-cage construct presents a potential solution. While tantalum cups have demonstrated favorable outcomes within the cup-cage construct, the efficacy of employing cup-cage constructs with titanium fibermesh remains to be elucidated. METHODS: We conducted a retrospective, single-center study of patients who had Paprosky type 3A or 3B acetabular bone loss and underwent cup-cage reconstruction with a cementless titanium fibermesh cup between 2011 and 2019, with a minimum 5-year follow-up period. Implant survivorship was assessed using Kaplan-Meier analyses, while clinical outcomes were evaluated, and sequential radiographic evaluations were performed to identify bone restoration processes. There were 29 patients included who had a mean age of 63 years (range, 41 to 82) and a mean follow-up duration of 125.7 months (range, 76 to 163). RESULTS: Cumulative implant survivorship was 97% at two years (95% confidence interval: 78 to 100) and 90% (95% confidence interval: 71 to 98) at five and 10 years. Radiographically, all cases (29 of 29) demonstrated graft incorporation and osseointegration, with medial acetabular wall restoration observed in instances of pelvic discontinuity, and the hip center was effectively restored. Postoperatively, there were significant improvements in functional outcomes (Harris Hip Score: preoperative 47.3 to postoperative 75.8; Oxford Hip Score: preoperative 21.0 to postoperative 37.8; Euro Quality-of-Life 5-dimension index: preoperative 0.49 to postoperative 0.82, P < 0.001 for all). Notably, no revisions were required for aseptic loosening during the study period. CONCLUSIONS: The findings suggest that utilization of cup-cage constructs with cementless titanium fibermesh cups is a viable and cost-effective alternative to the use of tantalum cups in cup-cage constructs during revision total hip arthroplasty. These results also suggest that the success of the cup-cage construct may be attributable to its fundamental concept rather than the specific use of tantalum cups. LEVEL OF EVIDENCE: Level IV, Therapeutic Study.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Chen IH, Tzeng SC, Wang CT, et al. Cementless Titanium Fibermesh Cup in Cup-Cage Construct for Severe Acetabular Defect in Revision Total Hip Arthroplasty. J Arthroplasty. 2025. PMID: 41205720. doi:10.1016/j.arth.2025.11.001

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。