文献速递关节外科

非对称内外侧屈曲松弛度目标在机器人辅助全膝关节置换术功能性膝关节定位中取得优异结果

An Asymmetric Medio-Lateral Flexion Laxity Target Yields Excellent Results in Robotic-Assisted Total Knee Arthroplasty With Functional Knee Positioning.
PubMed 文献 · J Arthroplasty · 2025-11-19

这项回顾性研究分析130例接受基于影像的机器人辅助全膝关节置换术并采用功能性膝关节定位的患者,术中调整目标为外侧屈曲松弛度比内侧大1至2毫米。术后至少一年随访显示遗忘关节评分12为87.4±14.5,内侧屈曲松弛度与遗忘关节评分12呈弱负相关(r=-0.18,P=0.047),外翻膝和内翻膝在计划与最终内侧伸直松弛度变化上存在差异,术前固定屈曲畸形大于10°的患者计划与最终伸直松弛度无差异。

要点

  • 最终松弛度中位数为内侧伸直1.5毫米、外侧伸直1.5毫米、内侧屈曲1.0毫米、外侧屈曲2.0毫米。
  • 术后一年遗忘关节评分12为87.4±14.5,内侧屈曲松弛度与遗忘关节评分12呈弱负相关(r=-0.18,P=0.047)。
  • 外翻膝较内翻膝在计划与最终内侧伸直松弛度变化更大(P<0.002),术前固定屈曲畸形大于10°者计划与最终伸直松弛度无差异(P<0.003)。

核心结论

  • 基于影像的机器人辅助全膝关节置换术采用功能性膝关节定位在一年时获得良好至优异的临床结果,并实现平衡的对称伸直松弛度。
  • 冠状面下肢力线和固定屈曲畸形显著影响计划与最终伸直松弛度之间的偏差,应在手术规划时予以考虑。

研究设计与样本

  • 回顾性研究分析130例接受基于影像的机器人辅助全膝关节置换术并采用功能性膝关节定位的患者,使用非骨水泥保留交叉韧带假体。

主要发现

  • 最终松弛度中位数:内侧伸直1.5毫米(1.0至2.0)、外侧伸直1.5毫米(1.1至2.0)、内侧屈曲1.0毫米(0.5至1.5)、外侧屈曲2.0毫米(1.5至2.5)。
  • 术后一年遗忘关节评分12为87.4±14.5。
  • 内侧屈曲松弛度与遗忘关节评分12呈弱负相关(r=-0.18,P=0.047),其他松弛度与患者报告结局指标无关联。
  • 敏感性分析显示无影响患者报告结局指标的相关松弛度截断值。
  • 外翻膝较内翻膝在计划与最终内侧伸直松弛度变化更大(P<0.002);术前固定屈曲畸形大于10°者与无固定屈曲畸形者不同,计划与最终伸直松弛度无差异(P<0.003)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Functional knee positioning (FKP) in robotic-assisted (RA) total knee arthroplasty (TKA) aims to optimize soft-tissue balance through patient-specific implant fine-tuning. However, it remains unclear (1) how intraoperative ligament laxity affects joint awareness and (2) whether the discrepancy between intraoperative planned and achieved laxity is affected by preoperative coronal limb alignment or fixed flexion deformity (FFD). METHODS: This retrospective study analyzed 130 patients undergoing image-based RA TKA with FKP using a cementless cruciate-retaining implant. Intraoperative adjustments were made to balance the flexion-extension laxity, targeting one to two mm larger lateral flexion laxity. Medial and lateral gaps before and after implant positioning were recorded at near extension and 90° flexion. Patient-reported outcome measures (PROMs), including the Forgotten Joint Score (FJS-12) and a 5-point Likert scale for satisfaction, were assessed at a minimum of one year postoperatively to investigate correlations between PROMs and final intraoperative laxities. The impact of preoperative coronal limb alignment, measured on long-leg radiographs, and FFD on final laxities was also evaluated. RESULTS: Final laxities were: median medial extension laxity 1.5 mm (1.0 to 2.0), lateral extension laxity 1.5 mm (1.1 to 2.0), medial flexion laxity 1.0 mm (0.5 to 1.5), and lateral flexion laxity 2.0 mm (1.5 to 2.5). At one year, the FJS-12 was 87.4 ± 14.5. A weak inverse correlation was observed between medial flexion laxity and FJS-12 (r = -0.18, P = 0.047); no other laxities were associated with PROMs. Sensitivity analyses showed no relevant laxity cutoffs influencing PROMs. Valgus knees exhibited larger changes between planned and final medial extension laxity compared with varus knees (P < 0.002). Unlike cases without FFD, those with preoperative FFD >10° showed no discrepancy between planned and final extension laxities (P < 0.003). CONCLUSIONS: Image-based RA TKA using FKP achieves good-to-excellent clinical outcomes at one year, with a balanced symmetric extension laxity. Coronal limb alignment and FFD significantly influence the deviation between planned and final extension laxity and should be considered during surgical planning.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Vermue H, Zambianchi F, Clemenza S, et al. An Asymmetric Medio-Lateral Flexion Laxity Target Yields Excellent Results in Robotic-Assisted Total Knee Arthroplasty With Functional Knee Positioning. J Arthroplasty. 2025. PMID: 41270986. doi:10.1016/j.arth.2025.11.030

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。