文献速递关节外科

维生素E注入高交联聚乙烯磨损低:随机放射立体分析研究14年随访

Low wear with vitamin E-infused highly cross-linked polyethylene : 14 years' follow-up of a randomized radiostereometric analysis study.
PubMed 文献 · Bone Joint J · 2025-11-01

这项前瞻性随机对照试验纳入2009年1月至2010年2月50髋行非骨水泥全髋关节置换术者,随机使用32或36毫米Biolox Delta陶瓷头,以无标记放射立体分析测量聚乙烯磨损。14年随访时32髋可分析,近端平均磨损32毫米组0.10毫米、36毫米组0.01毫米(p=0.022),磨合期后两组磨损无显著差异(p=0.628),临床结果优良。

要点

  • 14年随访时维生素E注入高交联聚乙烯配36毫米陶瓷头磨损极低。
  • 近端平均磨损32毫米组0.10毫米 vs 36毫米组0.01毫米(p=0.022)。
  • 磨合期后磨损32毫米组0.04毫米 vs 36毫米组0.02毫米(p=0.628)。

核心结论

  • 14年随访时,维生素E注入高交联聚乙烯配36毫米陶瓷头的聚乙烯磨损极低。
  • 磨合期后32毫米与36毫米头之间磨损无差异。
  • 临床结果优良。
  • Biolox Delta陶瓷头配维生素E注入高交联聚乙烯似乎是36毫米头的安全选择。

研究设计与样本

  • 前瞻性随机对照试验,2009年1月至2010年2月纳入50髋行非骨水泥全髋关节置换术,随机分为32毫米或36毫米Biolox Delta陶瓷头组。
  • 主要结局为无标记放射立体分析测量的聚乙烯磨损,次要结局为Harris髋关节评分、Oxford髋关节评分和UCLA活动量表评估的患者报告结局。

主要发现

  • 最终随访14年时,32髋可分析(32毫米组n=17,36毫米组n=15),18髋失访或排除:2髋因感染、1髋因假体周围骨折,这3髋因移除和/或更换假体组件被排除。
  • 近端方向平均聚乙烯磨损32毫米组为0.10毫米(95%CI 0.05至0.16),36毫米组为0.01毫米(95%CI -0.06至0.07),p=0.022。
  • 磨合期后磨损32毫米组为0.04毫米(95%CI -0.02至0.11),36毫米组为0.02毫米(95%CI -0.06至0.10),p=0.628。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: Highly cross-linked polyethylene (HXLPE) infused with vitamin E was introduced at the beginning of the 21st century. Vitamin E removes free radicals arising during gamma irradiation in order to cross-link the polyethylene. Removing free radicals was hypothesized to preserve mechanical properties and wear behaviour of the polyethylene in vivo. Excellent polyethylene wear behaviour of other HXLPEs has encouraged surgeons to use larger heads in total hip arthroplasty (THA) to address prosthesis dislocation. It is still unclear whether polyethylene wear remains low in the long term when using larger femoral heads. The aim of this study was to evaluate long-term polyethylene wear in uncemented THA with vitamin E-infused HXLPE liners with 32 or 36 mm ceramic femoral heads. METHODS: A total of 50 hips allocated to uncemented THA were included in this prospective randomized controlled trial from January 2009 to February 2010. They were randomized to either 32 or 36 mm Biolox Delta ceramic heads. The primary outcome was polyethylene wear measured with markerless radiostereometric analysis. The secondary outcome was patient-reported outcome measures measured by Harris Hip Score, Oxford Hip Score, and University of California, Los Angeles activity scale. RESULTS: At final follow-up (14 years), 32 hips were available for analysis (32 mm, n = 17; 36 mm, n = 15), and 18 hips had been lost to follow-up or were excluded: two hips due to infection, and one hip due to periprosthetic fracture. These three revised hips were excluded due to removal and/or change of prosthesis components. Mean polyethylene wear in the proximal direction was 0.10 mm (95% CI 0.05 to 0.16) and 0.01 mm (95% CI -0.06 to 0.07) for 32 and 36 mm femoral heads, respectively (p = 0.022). After the 'bedding-in' period wear was 0.04 mm (95% CI -0.02 to 0.11) and 0.02 mm (95% CI -0.06 to 0.10) for 32 and 36 mm, respectively (p = 0.628). CONCLUSION: Polyethylene wear was extremely low for vitamin E-infused HXLPE with 36 mm ceramic femoral heads at 14 years of follow-up. There was no difference in wear between 32 and 36 mm heads after the 'bedding-in' period. The clinical outcome was excellent. Biolox Delta ceramic heads on vitamin E-infused HXLPE seem to be a safe option for 36 mm heads.

来源:Bone Joint J,查看原文。版权归原作者所有。

引用

  1. Thoen PS, Lindalen E, Nordsletten L, et al. Low wear with vitamin E-infused highly cross-linked polyethylene : 14 years' follow-up of a randomized radiostereometric analysis study. Bone Joint J. 2025. PMID: 41173047. doi:10.1302/0301-620X.107B11.BJJ-2025-0273.R1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。