文献速递脊柱外科小儿骨科

超声曲线角比棘突角更准确,可减少学校脊柱侧凸筛查中不必要的X线检查:一项针对507名青少年女性的前瞻性与验证性研究

Ultrasound curve angle is more accurate than spinous process angle and can reduce unnecessary radiography in school scoliosis screening : a prospective and validation study in 507 adolescent females.
PubMed 文献 · Bone Joint J · 2025-11-01

在香港学校脊柱侧凸筛查中,对413名需X线检查的骨骼未成熟AIS女性进行前瞻性研究,并用94名女性验证,比较超声曲线角(UCA)与超声棘突角(SPA)预测转诊(Cobb角≥20°)的准确性。UCA模型敏感度0.94、特异度0.59,优于SPA模型的0.91和0.31;验证队列UCA敏感度0.95、特异度0.56,SPA为0.95和0.19。将超声纳入筛查流程可能减少56%至59%的不必要X线检查,UCA比SPA更准确且假阴性率更低。

要点

  • UCA预测转诊的敏感度0.94、特异度0.59,SPA为0.91和0.31。
  • 验证队列UCA敏感度0.95、特异度0.56,SPA为0.95和0.19。
  • 两队列合并假阴性6例(1.2%),UCA假阴性率低于SPA。

核心结论

  • 将超声纳入脊柱侧凸筛查流程,可能使骨骼未成熟AIS女性患者的不必要X线检查减少56%至59%。
  • UCA比SPA更准确且假阴性率更低,有潜力纳入常规筛查流程以减少不必要辐射。

研究设计与样本

  • 前瞻性研究,主要队列纳入413名经脊柱侧凸筛查建议行X线检查的女性,招募时间为2018年8月至2020年1月。
  • 验证队列纳入94名女性,招募时间为2020年1月至2023年1月。
  • 超声扫描按标准流程在与双平面X线(EOS系统)相同的设置下完成,采用逻辑回归模型评估超声判断转诊状态的准确性。

主要发现

  • 主要队列中,UCA逻辑回归模型预测阳性转诊状态的敏感度为0.94、特异度为0.59。
  • 主要队列中,SPA模型敏感度为0.91、特异度为0.31。
  • 验证队列中,UCA逻辑回归模型敏感度为0.95、特异度为0.56。
  • 验证队列中,SPA模型敏感度为0.95、特异度为0.19。
  • 两队列合并,6例(1.2%)被筛查为假阴性。

关键数值与推荐

  • 转诊标准为Cobb角≥20°时转诊。
  • UCA模型主要队列敏感度0.94、特异度0.59,验证队列敏感度0.95、特异度0.56。
  • SPA模型主要队列敏感度0.91、特异度0.31,验证队列敏感度0.95、特异度0.19。
  • 两队列合并假阴性6例(1.2%)。

临床怎么用

  • 作者认为,将超声纳入脊柱侧凸筛查流程可能减少骨骼未成熟AIS女性患者56%至59%的不必要X线检查。
  • 作者指出UCA比SPA更准确且假阴性率更低,有潜力纳入常规筛查流程以减少不必要辐射。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: The screening programme for adolescent idiopathic scoliosis (AIS) in Hong Kong results in more than 3,000 children undergoing radiographs of their spines annually. Some of those referred for radiography will have mild curves of Cobb angle < 20° that do not require specialist referral. A previous study suggested that augmenting the current screening programme with ultrasound spinous process angle (SPA) measurement could reduce unnecessary radiography by 51%. The ultrasound curve angle (UCA) was developed as a better method of measuring Cobb angle than the SPA. This study compares the measurement properties of UCA with SPA in determining referral status (referred when Cobb angle ≥ 20°) for specialist consultation in skeletally immature females with AIS. METHODS: A total of 413 females recommended for radiography by scoliosis screening were recruited from August 2018 to January 2020. Another cohort of 94 females was recruited for validation from January 2020 to January 2023. Ultrasound scanning was done according to a standard procedure at the same setting as biplanar radiography (EOS system). Logistic regression models were used to assess the accuracy of ultrasound in determining referral status. RESULTS: In the primary cohort, logistic regression model with UCA achieved a sensitivity of 0.94 and specificity of 0.59 to predict positive referral status. The SPA model achieved a sensitivity of 0.91 and specificity of 0.31. In the validation cohort, the logistic regression model with UCA achieved a sensitivity of 0.95 and specificity of 0.56. The model with SPA resulted in a sensitivity of 0.95 and specificity of 0.19. Combining both cohorts, six cases (1.2%) were screened as false-negative. CONCLUSION: Incorporation of ultrasonography into the scoliosis screening programme could potentially reduce unnecessary radiography by 56% to 59% in skeletally immature female patients with AIS. UCA was shown to be more accurate and have a lower false-negative rate than SPA, indicating the potential for its incorporation into the regular scoliosis screening workflow to reduce unnecessary radiation.

来源:Bone Joint J,查看原文。版权归原作者所有。

引用

  1. Kwan CK, Yang KG, Hung AL, et al. Ultrasound curve angle is more accurate than spinous process angle and can reduce unnecessary radiography in school scoliosis screening : a prospective and validation study in 507 adolescent females. Bone Joint J. 2025. PMID: 41173029. doi:10.1302/0301-620X.107B11.BJJ-2025-0121.R2

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。