股骨柄形状与几何构型在初次全髋关节置换术后翻修与并发症风险中的作用:系统综述与荟萃分析
该系统综述与荟萃分析纳入18项研究,比较解剖型、单锥型、单楔型和锥楔型股骨柄初次全髋关节置换术后的翻修与并发症风险。解剖型柄翻修率最高(3.9%),单锥型、单楔型和锥楔型柄翻修风险均较低;锥楔型柄假体周围关节感染风险最高;解剖型柄不稳定和假体周围骨折风险较高。
要点
- 解剖型柄翻修率最高(3.9%),单楔型柄翻修风险最低(RR 0.31)。
- 锥楔型柄假体周围关节感染风险最高(RR 2.52)。
- 解剖型柄假体周围骨折和不稳定风险均高于单锥型与单楔型柄。
核心结论
- 解剖型柄翻修、不稳定和骨折风险较高;锥楔型柄假体周围关节感染风险最高。
- 未来研究应聚焦于比较不同构型设计初次全髋关节置换术后特定并发症潜在增加风险的对照研究。
- 翻修风险在解剖型柄队列中最高。
研究设计与样本
- 系统综述与荟萃分析,检索PubMed、CINAHL Plus、EMBASE和SCOPUS四个电子数据库2015年1月至2025年1月的相关文献,最终纳入18项研究。
- 纳入股骨柄数量:解剖型12,969例、单锥型17,115例、单楔型19,326例、锥楔型1,965例。
主要发现
- 翻修率在解剖型柄队列中最高(3.9%;95%CI 3.6至4.2),单锥型(RR 0.38;95%CI 0.34至0.43;P=0.0001)、单楔型(RR 0.31;95%CI 0.27至0.35;P=0.0001)和锥楔型柄(RR 0.52;95%CI 0.4至0.68;P=0.0001)翻修率较低。
- 假体周围关节感染风险在解剖型柄中为0.22%(95%CI 0.15至0.31),单锥型(RR 2.12;95%CI 1.5至2.98;P=0.0002)和锥楔型队列(RR 2.52;95%CI 1.27至5.01;P=0.004)更高。
- 解剖型柄无菌性松动率为0.65%(95%CI 0.52至0.79),单楔型更低(RR 0.72;95%CI 0.56至0.92;P=0.014)。
- 解剖型柄不稳定风险为0.44%(95%CI 0.33至0.56),单锥型(RR 0.7;95%CI 0.51至0.94;P=0.025)和单楔型柄(RR 0.15;95%CI 0.09至0.25;P=0.0001)更低。
- 解剖型柄假体周围骨折发生率为1.4%(95%CI 1.2至1.6),单锥型(RR 0.74;95%CI 0.63至0.87;P=0.001)和单楔型队列(RR 0.21;95%CI 0.16至0.27;P=0.0001)更低。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Primary THA may be performed with femoral stems that differ in shape and geometry. The purpose of this meta-analysis was to evaluate the revision and complication risks of the following stem designs: (1) anatomic; (2) single-wedge; (3) single-taper; and (4) taper wedge. METHODS: A comprehensive search of four electronic databases (PubMed, CINAHL Plus, EMBASE, and SCOPUS) was performed for all articles pertaining to this topic from January 2015 to January 2025. A total of 18 studies were selected for inclusion. There were: (1) 12,969 anatomic; (2) 17,115 single-taper; (3) 19,326 single-wedge; and (4) 1,965 taper wedge stems. RESULTS: The revision rate was highest within the anatomic stem cohort (3.9%; 95% confidence interval [CI], 3.6 to 4.2), with lower rates being found in single-taper (relative risk [RR], 0.38; 95% CI, 0.34 to 0.43; P = 0.0001), single-wedge (RR, 0.31; 95% CI, 0.27 to 0.35; P = 0.0001), and taper wedged stems (RR, 0.52; 95% CI, 0.4 to 0.68; P = 0.0001). Periprosthetic joint infection risk was 0.22% (95% CI, 0.15 to 0.31) within anatomic stems and was higher in single-taper (RR, 2.12; 95% CI, 1.5 to 2.98; P = 0.0002) and taper wedge cohorts (RR, 2.52; 95% CI, 1.27 to 5.01; P = 0.004). Aseptic loosening rate with anatomic stems was 0.65% (95% CI, 0.52 to 0.79), and the single wedge was lower (RR, 0.72; 95% CI, 0.56 to 0.92; P = 0.014). The risk of instability in anatomic stems was 0.44% (95% CI, 0.33 to 0.56) with a much lower rate in single-taper (RR, 0.7; 95% CI, 0.51 to 0.94; P = 0.025) and single-wedge stems (RR, 0.15; 95% CI, 0.09 to 0.25; P = 0.0001). Periprosthetic fracture incidence in anatomic stems was 1.4% (95% CI, 1.2 to 1.6). The rates were much lower in single-taper (RR, 0.74; 95% CI, 0.63 to 0.87; P = 0.001) and single-wedge cohorts (RR, 0.21; 95% CI, 0.16 to 0.27; P = 0.0001). CONCLUSION: Anatomic stems had a higher risk of revision, instability, and fracture. The risk of periprosthetic joint infection was highest in taper wedge stems. Future research should focus on comparative studies that further investigate any potential increased risk of certain complications following primary THA based on various construct designs. Revision risk was highest in the anatomic stem cohort.
引用
- De C, Tahir M, Kumar RS, et al. The Role of Stem Shape and Geometry in Revision and Complication Risk Following Primary Total Hip Arthroplasty: A Systematic Review and Meta-Analysis. J Arthroplasty. 2025. PMID: 41161516. doi:10.1016/j.arth.2025.08.076
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。