文献速递关节外科

初次全髋关节置换术中非骨水泥髋臼组件与内衬分离发生率及全因翻修率

Incidence of Liner Dissociation and All-Cause Revision With Uncemented Acetabular Components in Primary Total Hip Arthroplasty.
PubMed 文献 · J Arthroplasty · 2025-10-14

基于美国登记库117,051例因骨关节炎行初次全髋关节置换并使用单极髋臼组件与高交联聚乙烯内衬的患者,按制造商分六组,采用Cox回归分析翻修风险。调整分析显示第一组(HR=1.51)和第四组(HR=1.35)全因翻修风险较高;13年内衬分离发生率第三组为0.25%,第一组为0.04%,第四组原文分别写作0.00%和0.15%,第五组为0.32%,第一组因内衬分离翻修风险较低(HR=0.12)。结论为使用最多的髋臼组件内衬分离发生率高于本队列中第二常用的杯/内衬组合。

要点

  • 第一组全因翻修风险高于参照组(HR=1.51,95%CI 1.30-1.75)。
  • 第四组全因翻修风险高于参照组(HR=1.35,95%CI 1.07-1.70)。
  • 第一组因内衬分离翻修风险低于参照组(HR=0.12,95%CI 0.04-0.33)。

核心结论

  • 在这项基于美国登记库的大型研究中,使用最多的髋臼组件内衬分离发生率高于本队列中第二常用的杯/内衬组合。

研究设计与样本

  • 纳入2009年至2022年间因骨关节炎行初次全髋关节置换术、使用单极髋臼组件和高交联聚乙烯内衬的18岁及以上患者117,051例。
  • 按制造商字母顺序分为六组:第一组(n=25,040)、第二组(n=11,819)、第三组(参照组,n=72,221)、第四组(n=3,233)、第五组(n=2,021)、第六组(n=2,717)。
  • 采用Cox比例风险回归模型分析随访期间的翻修情况。

主要发现

  • 调整分析中,第一组全因翻修风险较高(HR=1.51;95%CI 1.30-1.75),第四组全因翻修风险较高(HR=1.35;95%CI 1.07-1.70)。
  • 13年内衬分离发生率:第三组0.25%,第一组0.04%,第四组原文一处写作0.00%另一处写作0.15%(原文此处表述有矛盾),第五组0.32%。
  • 第一组因内衬分离翻修的风险较低(HR=0.12;95%CI 0.04-0.33),其13年内衬分离发生率为0.01%。
  • 全部失败中归因于内衬分离的比例:第一组0.4%,第二组0.4%,第三组4.0%,第四组0%,第五组1.2%,第六组0.9%。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Uncemented modular acetabular components are commonly used in total hip arthroplasty. Liner wear is uncommon since the introduction of highly crosslinked polyethylene. Our study goal was to identify the incidence of liner dissociation and all-cause revision by manufacturer. METHODS: We included 117,051 patients aged 18 years and older who underwent primary total hip arthroplasty for osteoarthritis with a unipolar acetabular component and highly crosslinked polyethylene liner between 2009 and 2022. There were six acetabular component treatment groups categorized alphabetically by manufacturer: group one (n = 25,040), group two (n = 11,819), group three (reference group) (n = 72,221), group four (n = 3,233), group five (n = 2,021), and group six (n = 2,717). Revision during follow-up was modeled using Cox proportional hazard regression. RESULTS: In adjusted analysis, group one (hazard ratio [HR] = 1.51; 95% confidence interval [CI] = 1.30 to 1.75) and group four (HR = 1.35, 95% CI = 1.07 to 1.70) had higher all-cause revision risks. Liner dissociation incidence at 13 years was 0.25% for group three, 0.04% for group one, 0.00% for group four, 0.15% for group four, and 0.32% for group five. It was 0.01% for group one, which had a lower risk for revision due to liner dissociation (HR = 0.12; 95% CI = 0.04 to 0.33). The percentage of all failures attributable to liner dissociation was 0.4% for group one, 0.4% for group two, 4.0% for group three, 0% for group four, 1.2% for group five, and 0.9% for group six. CONCLUSIONS: In this large United States-registry-based study, the most utilized acetabular component showed a higher incidence of liner dissociations compared to the second most used cup/liner combination in this cohort.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Singh G, Chan PH, Winston BA, et al. Incidence of Liner Dissociation and All-Cause Revision With Uncemented Acetabular Components in Primary Total Hip Arthroplasty. J Arthroplasty. 2025. PMID: 41101571. doi:10.1016/j.arth.2025.10.019

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。