固定平台全膝关节置换术使用非交联维生素E增强聚乙烯的临床结局:与常规聚乙烯平均九年随访的回顾性比较
回顾性队列研究纳入1994年4月至2016年7月间488例(661膝)初次全膝关节置换术患者,比较非交联维生素E增强聚乙烯(VEPE,169膝)与常规超高分子量聚乙烯(CPE,492膝)的临床结局。VEPE组与CPE组平均随访分别为9.0年(范围0.1至20.4)和9.9年(范围0.1至27.5),10年、15年、20年Kaplan-Meier生存率分别为97%、93%、93%和97%、92%、85%,两组再手术率分别为3.0%和5.5%(P=0.22),差异无统计学意义。结论认为非交联VEPE在平均约10年随访时临床结局与CPE相当。
要点
- VEPE组10年、15年、20年生存率分别为97%、93%、93%,CPE组分别为97%、92%、85%。
- VEPE组再手术率3.0%,CPE组5.5%,差异无统计学意义(P=0.22)。
- 唯一的磨损相关翻修发生在CPE组,VEPE组无磨损相关翻修。
核心结论
- 非交联VEPE在平均约10年随访时临床结局与CPE相当。
研究设计与样本
- 回顾性队列研究,纳入1994年4月至2016年7月间488例(661膝)初次全膝关节置换术患者,分为VEPE组169膝和CPE组492膝。
主要发现
- VEPE组平均随访9.0年(范围0.1至20.4),CPE组平均随访9.9年(范围0.1至27.5)。
- 10年、15年、20年Kaplan-Meier生存率VEPE组分别为97%、93%、93%,CPE组分别为97%、92%、85%。
- 再手术率VEPE组3.0%,CPE组5.5%,差异无统计学意义(P=0.22)。
- 唯一的磨损相关翻修发生在CPE组,VEPE组无磨损相关翻修。
- 两组间关节活动度和患者报告结局指标均无显著差异。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Ultra-high molecular weight polyethylene has long been widely used for inserts in total knee arthroplasty (TKA), and polyethylene wear is a factor affecting implant longevity. Vitamin E-enriched polyethylene (VEPE) was developed to enhance oxidative stability. This study compared the long-term clinical performance of non-cross-linked VEPE with that of conventional ultra-high molecular weight polyethylene (CPE) in TKA. METHODS: We conducted a retrospective cohort study involving 488 patients (661 knees) who underwent primary TKA between April 1994 and July 2016. Patients were divided into the VEPE (169 knees) and CPE (492 knees) groups. Clinical outcomes, including implant survival, reoperation rates, range of motion, and patient-reported outcome measures, were assessed. RESULTS: At a mean follow-up of 9.0 (range, 0.1 to 20.4) and 9.9 (range, 0.1 to 27.5) years for the VEPE and CPE groups, the Kaplan-Meier survival rates at 10, 15, and 20 years were 97, 93, and 93%, respectively, for the VEPE group and 97, 92, and 85%, respectively, for the CPE group. Reoperation rates were 3.0 and 5.5% in the VEPE and CPE groups, respectively, showing no statistically significant difference (P = 0.22). The one wear-related revision occurred in the CPE group and none in the VEPE group. There were no significant differences observed between groups in range of motion or patient-reported outcome measures. CONCLUSIONS: Non-cross-linked VEPE demonstrated clinical outcomes comparable to those of CPE in TKA at a mean follow-up of approximately 10 years.
引用
- Hamada T, Watanabe S, Hayashi N, et al. Clinical Outcomes of Fixed-Bearing Total Knee Arthroplasty Using Non-Cross-Linked Vitamin E-Enriched Polyethylene: A Retrospective Comparison With Conventional Polyethylene at Mean Nine-Year Follow-Up. J Arthroplasty. 2025. PMID: 41106709. doi:10.1016/j.arth.2025.10.025
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。