循环噬菌体DNA可区分葡萄球菌感染与共生定植
本研究在既往葡萄球菌假体周围关节感染(PJI)、现症PJI及无PJI三组患者中检测血浆游离DNA中的噬菌体序列,发现现症PJI组和无PJI组葡萄球菌噬菌体比例中位数分别为2.6%和0%,既往PJI组为1.0%。葡萄球菌噬菌体存在鉴别葡萄球菌PJI的敏感性为60%、特异性为92%。
要点
- 现症PJI组葡萄球菌噬菌体比例中位数2.6%,显著高于无PJI组的0%(P=0.013)。
- 既往PJI组葡萄球菌噬菌体比例中位数1.0%,显著高于无PJI组的0%(P=0.049)。
- 葡萄球菌噬菌体存在鉴别葡萄球菌PJI的敏感性60%、特异性92%。
核心结论
- 血浆噬菌体游离DNA为检测和监测葡萄球菌PJI提供了有前景的方法。
- 既往PJI中葡萄球菌噬菌体的持续存在可能反映亚临床感染或标准培养诊断无法检测的残留微生物DNA。
研究设计与样本
- 研究纳入现症葡萄球菌PJI、既往PJI和无PJI三个不同患者队列,采用既往描述的计算流程从血浆游离DNA中鉴定噬菌体序列。
- 研究描述了三个队列的整体噬菌体组,比较三组间葡萄球菌噬菌体比例,并将葡萄球菌噬菌体作为二分类变量分析其诊断性能。
主要发现
- 三个队列间细菌游离DNA分布无差异(P=0.597)。
- 现症PJI组葡萄球菌噬菌体比例中位数2.6%,显著高于无PJI组的0%(P=0.013)。
- 既往PJI组葡萄球菌噬菌体比例中位数1.0%,显著高于无PJI组的0%(P=0.049)。
- 现症PJI组与既往PJI组葡萄球菌噬菌体比例无差异(中位数2.6% vs 1.0%,P=0.554)。
- 葡萄球菌噬菌体在现症PJI组10例样本中6例存在,既往PJI组12例样本中7例存在,无PJI组13例样本中1例存在。
关键数值与推荐
- 葡萄球菌噬菌体存在鉴别葡萄球菌PJI的敏感性为60%,特异性为92%。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Bacteriophage sequences from cell-free DNA (cfDNA) in plasma can be used to diagnose bacterial pathogens during sepsis. Here, we hypothesize that plasma bacteriophage cfDNA can serve as a serological biomarker to monitor Staphylococcal periprosthetic joint infection (PJI). METHODS: Using a previously described computational pipeline, bacteriophage sequences were identified in cfDNA from plasma of three distinct patient cohorts: patients with a current Staphylococcal PJI, prior PJI, and no PJI. The overall phageome was described in all three cohorts, and the proportion of Staphylococcus bacteriophage was compared among the three cohorts. The presence of Staphylococcus bacteriophage as a binary variable was also analyzed for its diagnostic performance in identifying Staphylococcal PJI. RESULTS: There were no differences in the distribution of bacterial cfDNA among the three cohorts (P = 0.597). The current PJI cohort had a significantly higher proportion of Staphylococcus bacteriophage compared to no PJI (median, 2.6 versus 0%, P = 0.013), and the prior PJI cohort had a significantly higher proportion of Staphylococcus bacteriophage compared to no PJI (median, 1.0 versus 0%, P = 0.049). Of note, there was no difference in proportion of Staphylococcus bacteriophage between current PJI and prior PJI (median, 2.6% versus 1.0%, P = 0.554). Staphylococcus bacteriophage was present in six of ten samples in current PJI, seven of 12 samples in prior PJI, and one of 13 samples in the no PJI groups. The presence of Staphylococcus bacteriophage had a sensitivity of 60% and specificity of 92% for a Staphylococcal PJI. CONCLUSIONS: These findings suggest that plasma bacteriophage cfDNA offers a promising approach to detect and monitor Staphylococcal PJI. The persistence of these Staphylococcus bacteriophages in prior PJI may reflect subclinical infection or residual microbial DNA undetectable by standard culture-based diagnostics.
引用
- Manasherob R, Furukawa D, Haddock NL, et al. Circulating Bacteriophage DNA Distinguishes Staphylococcal Infection From Commensal Colonization. J Arthroplasty. 2025. PMID: 41072561. doi:10.1016/j.arth.2025.09.051
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。