外侧单间室膝关节置换术的结局与假体生存率:少有人走的路
该研究回顾性分析了2001年1月至2023年5月单中心548例外侧固定平台骨水泥型单间室膝关节置换术,10年假体生存率为95.7%,翻修率3.5%,翻修最常见原因为骨关节炎进展(14例),术后下肢力线与翻修无显著差异,作者认为外侧单间室膝关节置换术是持久且保留关节的选择。
要点
- 10年假体生存率为95.7%,翻修率3.5%,翻修最常见原因为骨关节炎进展(14例)。
- 早期(≤90天)并发症率为2.2%,11例(2.0%)需再手术但未翻修。
- 翻修与未翻修病例术后下肢力线无显著差异。
核心结论
- 外侧单间室膝关节置换术显示出优异的10年假体生存率和低并发症率。
- 大多数翻修是由于关节炎进展,且与术后力线无关。
- 这些发现支持外侧单间室膝关节置换术作为经适当选择患者的持久、保留关节的选择。
研究设计与样本
- 回顾性研究,纳入2001年1月至2023年5月单中心548例固定平台骨水泥型外侧单间室膝关节置换术,98.5%诊断为骨关节炎,71%为女性,平均年龄67岁(范围28至93),平均体重指数27.8(范围18.0至49.5)。
主要发现
- 10年假体生存率为95.7%。
- 19例(3.5%)需翻修,平均在位时间6.5年,翻修原因:骨关节炎进展14例,无菌性松动3例,假体周围骨折1例,感染1例。
- 额外11例(2.0%)需再手术但未翻修;早期(≤90天)并发症率为2.2%。
- 翻修与未翻修病例的术后下肢力线无显著差异。
- 未翻修患者平均术前和术后胫股角分别为9.8°和5.3°外翻。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Unicompartmental knee arthroplasty (UKA) is an effective treatment for isolated lateral compartment osteoarthritis (OA). Surgeons have been reticent to adopt this procedure due to the difficulty of exposure and historically higher rates of revision when compared to total knee arthroplasty (TKA). The purpose of this study was to evaluate our series of lateral UKAs. METHODS: We retrospectively reviewed 548 fixed-bearing, cemented lateral UKAs performed at a single institution between January 2001 and May 2023. The diagnosis was OA in 98.5% of cases, and 71% of patients were women. The average age and body mass index at the time of surgery were 67 years (range, 28 to 93) and 27.8 (range, 18.0 to 49.5), respectively. The primary outcomes included implant survivorship and revision rate with associated causes. The secondary outcomes included complication rates and analysis of preoperative and postoperative tibio-femoral angle. RESULTS: The 10-years survivorship was 95.7%. There were 19 cases (3.5%) that required revision after a mean time in situ of 6.5 years, most commonly due to progression of OA (n = 14), followed by aseptic loosening (n = three), periprosthetic fracture (n = one), and infection (n = one). An additional 11 cases (2.0%) required reoperation without revision. The early (≤ 90 days) complication rate was 2.2%. Postoperative limb alignment did not differ significantly between revised and non-revised cases. In nonrevised patients, mean preoperative and postoperative tibio-femoral angle was 9.8 and 5.3° valgus, respectively. Patients revised for OA progression had similar alignment (preoperative 11.6°, P = 0.15; postoperative 5.3°, P = 0.94). CONCLUSIONS: Lateral UKA demonstrated excellent 10-years survivorship and a low complication rate. Most revisions were due to the progression of arthritis, which occurred independently of postoperative alignment. These findings support lateral UKA as a durable, joint-preserving option for appropriately selected patients.
引用
- Nwankwo TN, Li KK, Parks NL, et al. Outcomes and Implant Survival in Lateral Unicompartmental Knee Arthroplasty: The Path Less Traveled. J Arthroplasty. 2025. PMID: 41161509. doi:10.1016/j.arth.2025.10.050
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。