单髁膝关节置换术治疗孤立间室骨坏死:20年经验
回顾性分析2002至2022年单中心70例因骨坏死行单髁膝关节置换术(UKA)的病例,平均随访8年。全队列10年无翻修生存率为91%,继发性骨坏死是翻修(HR=17)和再手术(HR=14)的显著危险因素。作者认为UKA对原发性骨坏死持久可靠,但对继发性骨坏死失败率显著更高。
要点
- 全队列10年无任何翻修生存率91%,无再手术生存率88%。
- 继发性骨坏死翻修风险显著更高(HR=17,P<0.001),再手术风险也更高(HR=14,P=0.002)。
- 翻修主要因外侧间室骨关节炎进展(3膝),无因骨折或磨损翻修。
核心结论
- 作者认为,在8年随访中,UKA对原发性骨坏死是持久可靠的选择。
- 作者指出,用于继发性骨坏死时失败率显著更高,主要与骨坏死进展或外侧间室骨关节炎发生相关。
研究设计与样本
- 回顾性识别2002至2022年 single tertiary care academic institution 连续70例因骨坏死行UKA,64例(91%)为原发性,6例(9%)为继发性。
- 骨坏死位于内侧股骨髁61例(87%)、内侧胫骨平台6例(9%)、外侧股骨髁3例(4%)。
- 所有UKA均骨水泥固定,77%采用固定平台设计,23%采用活动平台设计;平均年龄66岁,59%为女性,平均随访8年(范围2至20年)。
- 证据等级III,回顾性队列研究。
主要发现
- 全队列10年无任何翻修生存率为91%,无任何再手术生存率为88%。
- 翻修主要原因为外侧间室发生骨关节炎(3膝),无假体因骨折或磨损翻修。
- 继发性骨坏死是无任何翻修生存率更差的显著危险因素(HR=17;P<0.001),也是无任何再手术生存率更差的显著危险因素(HR=14;P=0.002)。
- 膝关节学会功能评分从术前平均54改善至术后平均75。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Osteonecrosis of the knee, whether primary (spontaneous) or secondary, can often necessitate surgical intervention. If advanced osteonecrosis is confined to a single compartment, unicompartmental knee arthroplasty (UKA) is often considered. The purpose of this study was to update and extend our prior series, with specific emphasis on implant survivorship, radiographic results, clinical outcomes, and complications in a concise cohort of UKAs for osteonecrosis. METHODS: We retrospectively identified 70 consecutive UKAs for osteonecrosis performed at a single tertiary care academic institution from 2002 to 2022. Of these, 64 UKAs (91%) were performed for primary osteonecrosis, and six UKAs (9%) were performed for secondary osteonecrosis. Osteonecrosis was in the medial femoral condyle in 61 UKAs (87%), medial tibial plateau in six UKAs (9%), and lateral femoral condyle in three UKAs (4%). All UKAs were cemented, with 77% utilizing a fixed-bearing design and 23% utilizing a mobile-bearing design. The mean patient age was 66 years, with 59% being women. The mean follow-up was eight years (range, two to 20). RESULTS: The 10-year survivorship free of any revision for the entire cohort was 91%. The predominant indication for revision was the development of osteoarthritis in the lateral compartment in three knees. The 10-year survivorship free of any reoperation was 88%. The secondary osteonecrosis was a significant and substantial risk factor for worse survivorship free of any revision (hazard ratio (HR) = 17; P < 0.001) and any reoperation (HR = 14; P = 0.002). There were no implants that were revised for fracture or wear. Knee society function scores improved from a mean of 54 preoperatively to a mean of 75 postoperatively. CONCLUSIONS: A UKA is a durable and reliable option for primary osteonecrosis at eight years of follow-up. However, when performed for secondary osteonecrosis, it has a substantially higher failure rate, primarily related to the progression of osteonecrosis or development of osteoarthritis in the lateral compartment. LEVEL OF EVIDENCE: III, Retrospective Cohort Study.
引用
- Meissner N, Bukowski BR, Larson DR, et al. Unicompartmental Knee Arthroplasty for Isolated Compartment Osteonecrosis: A 20-Year Experience. J Arthroplasty. 2025. PMID: 41138995. doi:10.1016/j.arth.2025.10.044
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。