文献速递关节外科创伤骨科

三锥度带领股骨柄形态影响假体周围股骨骨折风险:单锥度、双锥度、三锥度与四锥度股骨柄的比较

Triple-Taper Collared Stem Morphology Influences Periprosthetic Femoral Fracture Risk: A Comparison of Single-, Dual-, Triple-, and Quadrangular-Taper Stems.
PubMed 文献 · J Arthroplasty · 2025-10-23

单机构回顾性队列研究纳入2016年2月至2023年12月23448例非骨水泥全髋关节置换术,比较单锥度、双锥度、三锥度带领和四锥度股骨柄的假体周围股骨骨折发生率。三锥度带领柄的术中及术后骨折率最低,校正年龄、性别、BMI、ASA评分、吸烟和手术入路后,其术中骨折风险低于双锥度和四锥度柄,术后骨折风险低于双锥度柄。

要点

  • 三锥度带领柄的假体周围股骨骨折总发生率为0.37%,低于单锥度0.70%、双锥度1.34%和四锥度1.09%。
  • 三锥度带领柄术中骨折率0.25%,术后骨折率0.12%,均为各组最低。
  • 校正混杂因素后,三锥度带领柄术中骨折风险低于双锥度(OR 0.3)和四锥度(OR 0.3),术后骨折风险低于双锥度(OR 0.3)。

核心结论

  • 在超过23000例非骨水泥全髋关节置换术队列中,三锥度带领股骨柄的术中及术后假体周围股骨骨折发生率低于其他非骨水泥股骨柄形态。

研究设计与样本

  • 单机构回顾性队列研究,纳入2016年2月至2023年12月所有初次非骨水泥全髋关节置换术病例共23448例。
  • 按股骨柄形态分为四组:单锥度8529例、双锥度8514例、三锥度带领4024例、四锥度2381例,来自四家主要植入物公司。
  • 结局为任何假体周围股骨骨折、术中骨折和早期(90天)术后骨折。

主要发现

  • 任何假体周围股骨骨折:单锥度60/8529(0.70%)、双锥度114/8514(1.34%)、三锥度带领15/4024(0.37%)、四锥度26/2381(1.09%),总体差异P < 0.01。
  • 术中骨折:单锥度30例(0.35%)、双锥度69例(0.81%)、三锥度带领10例(0.25%)、四锥度22例(0.92%),P < 0.01。
  • 术后骨折:单锥度30例(0.35%)、双锥度47例(0.55%)、三锥度带领5例(0.12%)、四锥度4例(0.17%),P < 0.01。
  • 带领柄(包括四锥度带领柄)术后骨折率低于非带领柄(0.15% vs 0.44%,P < 0.01)。
  • 校正年龄、性别、体重指数、美国麻醉医师协会评分、烟草使用和手术入路后,三锥度带领柄术中骨折风险低于双锥度柄(OR 0.3,P < 0.01)和四锥度柄(OR 0.3,P < 0.01);术后骨折风险低于双锥度柄(OR 0.3,P < 0.01)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Stem morphology is an important contributor to periprosthetic femoral fracture (PFF) risk following total hip arthroplasty (THA). New-generation triple-taper collared stems may be associated with a lower risk of PFF. Our objective was to compare the incidence of PFFs in triple-taper collared stems to three other cementless stem morphologies. METHODS: A single-institution retrospective cohort study was performed. All primary THA cases (n = 23,448) from February 2016 to December 2023 using cementless single-taper (n = 8,529), dual-taper (n = 8,514), triple-taper collared (n = 4,024), and quadrangular-taper stems (n = 2,381) from four major implant companies were evaluated. Outcomes were any PFF, intraoperative PFF, and early (90 days) postoperative PFF. RESULTS: Any PFF occurred in 60 of 8,529 (0.70%) single-taper, 114 of 8,514 (1.34%) dual-taper, 15 of 4,024 (0.37%) triple-taper collared, and 26 of 2,381 (1.09%) quadrangular-taper stems (overall difference, P < 0.01). Intraoperative fractures occurred in 30 single-taper (0.35%), 69 dual-taper (0.81%), 10 triple-taper collared (0.25%), and 22 (0.92%) quadrangular-taper stems (P < 0.01). Postoperative fractures occurred in 30 single-taper (0.35%), 47 dual-taper (0.55%), five triple-taper collared (0.12%), and four (0.17%) quadrangular-taper stems (P < 0.01). Collared stems (including quadrangular-taper collared stems) had a lower postoperative fracture rate compared to noncollared stems (0.15 versus 0.44%, P < 0.01). After accounting for age, sex, body mass index, American Society of Anesthesiologists' score, tobacco use, and surgical approach, triple-taper collared stems had a lower risk of intraoperative fracture compared to dual-taper (odds ratio (OR) 0.3, P < 0.01) and quadrangular-taper stems (OR 0.3, P < 0.01). The triple-taper collared stems also had a lower rate of postoperative fracture compared to dual-taper stems (OR 0.3, P < 0.01). CONCLUSIONS: In a cohort of over 23,000 patients undergoing cementless THA, triple-taper collared femoral stems had the lowest rates of intra-operative and postoperative PFF compared to other cementless stem morphologies.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. LeBrun DG, Ruiz V, Gausden EB, et al. Triple-Taper Collared Stem Morphology Influences Periprosthetic Femoral Fracture Risk: A Comparison of Single-, Dual-, Triple-, and Quadrangular-Taper Stems. J Arthroplasty. 2025. PMID: 41138996. doi:10.1016/j.arth.2025.10.045

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。