文献速递创伤骨科

髋部骨折后并发症对生活质量和死亡率的影响

The impact of complications on quality of life and mortality after hip fracture.
PubMed 文献 · Bone Joint J · 2025-10-01

世界髋部创伤评估(WHiTE)多中心前瞻性队列研究纳入24523例≥60岁接受手术的髋部骨折患者,随访120天。假体脱位、深部手术部位感染、脑血管意外和心肌梗死等并发症与健康相关生活质量(EQ-5D-5L)较差相关。

要点

  • 假体脱位者EQ-5D-5L平均差异为-0.14(95%CI -0.20至-0.08)。
  • 深部手术部位感染者EQ-5D-5L平均差异为-0.13(95%CI -0.20至-0.07)。
  • 脑血管意外者EQ-5D-5L平均差异为-0.17(95%CI -0.25至-0.09)。

核心结论

  • 髋部骨折后发生并发症的患者健康相关生活质量较差。
  • 接受翻修手术、假体脱位或深部手术部位感染的患者在120天时的残疾程度与脑血管意外或心肌梗死患者相似。

研究设计与样本

  • 世界髋部创伤评估(WHiTE)研究为多中心前瞻性队列研究。
  • 纳入≥60岁接受手术治疗的髋部骨折患者,术后随访120天。
  • 主要结局为健康相关生活质量(EQ-5D-5L),次要结局为死亡率。
  • 采用线性回归和逻辑回归模型评估并发症与EQ-5D-5L及死亡率的关系。

主要发现

  • 手术相关并发症的EQ-5D-5L平均差异:假体脱位-0.14(95%CI -0.20至-0.08);内固定失败0.00(95%CI -0.15至0.14);假体周围或植入物周围骨折-0.08(95%CI -0.18至0.02);任何指征再手术-0.09(95%CI -0.14至-0.05);手术部位感染(SSI)-0.06(95%CI -0.10至-0.01);深部SSI -0.13(95%CI -0.20至-0.07)。
  • 一般并发症的EQ-5D-5L平均差异:急性肾损伤-0.05(95%CI -0.07至-0.02);输血-0.01(95%CI -0.03至0.01);下呼吸道感染-0.07(95%CI -0.09至-0.05);尿路感染0.01(95%CI -0.01至0.03);脑血管意外(CVA)-0.17(95%CI -0.25至-0.09);心肌梗死(MI)-0.14(95%CI -0.20至-0.08);静脉血栓栓塞0.03(95%CI -0.02至0.08)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: There is limited information on how the development of complications influences quality of life (QoL) after hip fracture. The aim of this study was to investigate the relationship between complications, QoL, and mortality after hip fracture. METHODS: The World Hip Trauma Evaluation (WHiTE) study is a multicentre, prospective cohort study that collected data from patients aged ≥ 60 years who received surgical treatment for their hip fracture. Patients were followed up for 120 days after surgery. The primary and secondary outcomes were health-related QoL (EuroQol five-dimension five-level questionnaire; EQ-5D-5L) and mortality, respectively. Linear and logistic regression models were fitted to assess the relationship between complications, EQ-5D-5L, and mortality. RESULTS: Among 24,523 patients with a hip fracture, the mean differences in EQ-5D-5L in patients who had surgery-specific complications were: prosthesis dislocation -0.14 (95% CI -0.20 to -0.08); fixation failure 0.00 (95% CI -0.15 to 0.14); periprosthetic or peri-implant fracture -0.08 (95% CI -0.18 to 0.02); reoperation for any indication -0.09 (95% CI -0.14 to -0.05); surgical site infection (SSI) -0.06 (95% CI -0.10 to -0.01); and deep SSI -0.13 (95% CI -0.20 to -0.07). The mean differences in EQ-5D-5L for the general complications were: acute kidney injury -0.05 (95% CI -0.07 to -0.02); blood transfusion -0.01 (95% CI -0.03 to 0.01); lower respiratory tract infection -0.07 (95% CI -0.09 to -0.05); urinary tract infection 0.01 (95% CI -0.01 to 0.03); cerebrovascular accident (CVA) -0.17 (95% CI -0.25 to -0.09); myocardial infarction (MI) -0.14 (95% CI -0.20 to -0.08); and venous thromboembolism 0.03 (95% CI -0.02 to 0.08). CONCLUSION: We observed worse health-related QoL in patients who had a complication after hip fracture. Those who underwent revision surgery or had a prosthesis dislocation or deep SSI experienced similar levels of disability at 120 days to those with a CVA or MI.

来源:Bone Joint J,查看原文。版权归原作者所有。

引用

  1. Goh EL, Png ME, Metcalfe D, et al. The impact of complications on quality of life and mortality after hip fracture. Bone Joint J. 2025. PMID: 41027598. doi:10.1302/0301-620X.107B10.BJJ-2024-1448.R1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。