初次与翻修全膝关节置换术后血液、血清及组织中金属浓度的系统综述
该系统综述纳入33项报告全膝关节置换(TKA)术后金属浓度的研究,汇总全血中钴中位数1.42 ppb、铬1.44 ppb,血清中钴3.19 ppb、铬0.95 ppb,假体周围组织浓度普遍更高;11项报告临界阈值的研究中64%采用≥2 ppb,翻修与组配式TKA的全血钴、铬浓度显著高于初次与一体式TKA(P < 0.05)。
要点
- TKA术后全血钴、铬中位数分别为1.42 ppb与1.44 ppb,两者线性相关(R² = 0.98)。
- 血清钴、铬中位数分别为3.19 ppb与0.95 ppb,假体周围组织金属浓度普遍更高。
- 翻修与组配式TKA全血钴、铬浓度显著高于初次与一体式TKA(P < 0.05)。
核心结论
- 膝关节金属释放的认识仍存在空白,测量假体周围组织浓度的研究少,金属向器官转运的程度未知。
- 研究多采用源自金属对金属全髋关节置换的阈值,需要制定针对膝关节的新指南。
- 作者建议外科医生应知道初次TKA患者存在金属释放,仔细权衡限制性假体的必要性与金属释放的潜在风险,并考虑以替代轴承替代金属对金属铰链,因体内已记录到高钴、铬浓度。
研究设计与样本
- 系统综述,检索PubMed与Embase数据库中报告TKA术后金属浓度的研究。
- 33项研究符合纳入标准并接受后续筛选。
- 采用线性回归评估全血与血清中的相关性,采用非参数统计比较假体设计。
主要发现
- TKA术后全血钴中位数1.42 ppb、铬中位数1.44 ppb,两者呈线性相关(R² = 0.98)。
- 血清钴中位数3.19 ppb、铬中位数0.95 ppb。
- 假体周围组织金属释放浓度普遍更高。
- 11项报告临界阈值的研究中,多数(64%)采用≥2 ppb。
- 翻修与组配式TKA的全血钴、铬浓度显著高于初次与一体式TKA(P < 0.05)。
关键数值与推荐
- 全血钴中位数1.42 ppb、铬中位数1.44 ppb。
- 血清钴中位数3.19 ppb、铬中位数0.95 ppb。
- 全血钴与铬线性相关R² = 0.98。
- 11项报告临界阈值的研究中64%采用≥2 ppb。
- 翻修与组配式TKA对比初次与一体式TKA的全血钴、铬浓度P < 0.05。
临床怎么用
- 作者建议外科医生应知道初次TKA患者存在金属释放。
- 作者建议外科医生应仔细权衡限制性假体的必要性与金属释放的潜在风险。
- 作者建议考虑以替代轴承替代金属对金属铰链,因体内已记录到高钴、铬浓度。
局限性
- 膝关节金属释放的认识仍存在空白。
- 测量假体周围组织浓度的研究少。
- 金属向器官转运的程度未知。
- 研究多采用源自金属对金属全髋关节置换的阈值,需要制定针对膝关节的新指南。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: In a subset of total hip arthroplasty (THA) patients, investigators associate metal release with biological complications. Comparatively, metal release in the knee is less understood. In this study, we systematically reviewed total knee arthroplasty (TKA) metal release studies. We asked: (1) What are the metal concentrations reported in TKA patients? (2) What concentrations do studies use as thresholds? and (3) Does implant design affect metal concentrations in vivo? METHODS: The PubMed and Embase databases were searched for studies reporting metal concentrations following TKA. There were 33 studies that met the inclusion criteria and were subsequently screened. Linear regressions were used to assess correlations in whole blood and serum, and nonparametric statistics were used to compare implant designs. RESULTS: Following TKA, studies reported median whole blood concentrations of 1.42 parts per billion (ppb) (cobalt) and 1.44 ppb (chromium). Release of the two metals correlated linearly (R2 = 0.98). In serum, the documented median values were 3.19 ppb (cobalt) and 0.95 ppb (chromium). Generally, investigators reported higher concentrations of metal release within the periprosthetic tissue. Of the 11 studies that reported a critical threshold value, most studies (64%) used ≥ two ppb. Revision and modular TKA studies measured significantly higher cobalt and chromium concentrations in whole blood compared to primary and monobloc TKA (P < 0.05). CONCLUSIONS: In the knee, gaps persist in our knowledge of metal release. Few studies measure concentrations in the periprosthetic tissue, and the magnitude of metal transport to organs remains unknown. Additionally, studies largely use thresholds derived from metal-on-metal (MoM) total hip arthroplasty, necessitating new guidelines for the knee. Surgeons should (1) know that metal release occurs in primary TKA patients; (2) carefully weigh the necessity of constrained devices versus the potential for metal release; and (3) consider alternative bearings to metal-on-metal hinges due to the high cobalt and chromium concentrations documented in vivo.
引用
- Aslani S, Kurtz MA, Spece H, et al. Systematic Review of Metal Concentrations in Blood, Serum, and Tissue Following Primary and Revision Total Knee Arthroplasty. J Arthroplasty. 2025. PMID: 40912336. doi:10.1016/j.arth.2025.08.078
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。