多孔钽臼杯重建治疗病理性髋臼骨折的疗效
回顾性研究纳入2010至2022年62例因病理性骨折接受髋臼假体治疗的患者,其中44例为转移性疾病。术后Harris髋关节评分从36.2升至76.9(P<0.01),翻修率为11.3%,无菌性松动翻修率为1.6%。钽杯-笼架与单独钽杯两种重建方式的翻修率无差异(P=0.69)。
要点
- 病理性髋臼骨折行钽杯或杯-笼架重建后Harris髋关节评分显著提高(36.2升至76.9,P<0.01)。
- 总体翻修率为11.3%,无菌性松动翻修率为1.6%,两种重建方式翻修率无差异(P=0.69)。
- 在有或无骨盆不连续的患者中均可获得满意结果,但需根据骨折严重程度选择性应用。
核心结论
- 病理性髋臼骨折后行关节置换在有或无骨盆不连续的患者中均获得满意结果。
- 钽杯-笼架与单独钽杯重建根据髋臼骨折严重程度选择性应用时,可提供持久结果和满意的翻修率。
研究设计与样本
- 回顾性研究,纳入2010年至2022年间62例(28男、35女)因病理性骨折接受髋臼假体治疗的患者。
- 平均年龄63岁(范围28.8至86.9),平均体重指数29.1(范围17.2至48.9)。
- 最常见诊断为转移性疾病(n=44),48例在发生病理性骨折前接受过放射治疗。
- 41例采用钽杯-笼架重建,21例采用单独钽杯;24例存在骨盆不连续(22例杯-笼架,2例单独杯)。
- 存活患者平均随访5.4年(范围1.2至13.8)。
主要发现
- 7例患者出现影像学假体松动证据。
- 总体翻修率为11.3%,无菌性松动翻修率为1.6%。
- 末次随访时33例患者死亡。
- 两种重建方式的翻修率无差异(P=0.69)。
- 重建后Harris髋关节评分从36.2升至76.9(P<0.01)。
关键数值与推荐
- 总体翻修率11.3%,无菌性松动翻修率1.6%。
- 杯-笼架组与单独杯组翻修率比较P=0.69。
- Harris髋关节评分术前36.2,术后76.9,P<0.01。
临床怎么用
- 原文未据此给出推荐。
局限性
- 证据等级为IV级。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The periacetabular region is a common location for secondary malignancies. The purpose of this study was to assess outcomes following acetabular reconstruction in patients sustaining periacetabular pathologic fractures. METHODS: This retrospective study examined 62 patients (28 men and 35 women) who received an acetabular implant for management of a pathologic fracture between 2010 and 2022. The mean age and body mass index were 63 years (range, 28.8 to 86.9) and 29.1 (range, 17.2 to 48.9), respectively. The most common diagnosis was metastatic disease (n = 44). There were 48 patients who underwent radiation therapy for the management of their disease before sustaining a pathologic fracture. Medical records and radiographs were reviewed. The mean follow-up of surviving patients was 5.4 years (range, 1.2 to 13.8). There were 41 patients who received a tantalum cup-cage construct for acetabular reconstruction, while 21 patients received a tantalum cup alone. At the time of surgery, 24 patients demonstrated pelvic discontinuity (22 cup-cage and two cup alone). RESULTS: There were seven patients who demonstrated radiographic evidence of implant loosening. The overall revision rate was 11.3 and 1.6% for aseptic loosening. At the most recent follow-up, there were 33 patients who were deceased. There were no differences in revision rate between reconstructive methods (P = 0.69). After reconstruction, Harris Hip Scores increased from 36.2 to 76.9 postoperatively (P < 0.01). The cumulative incidence of death was higher than that of revision at all evaluated timepoints. CONCLUSIONS: Arthroplasty following pathologic acetabular fractures resulted in satisfactory outcomes in patients who had and did not have a pelvic discontinuity. Tantalum cup-only and cup-cage constructs provide durable results with satisfactory revision rates when applied selectively based on the severity of the acetabular fracture. LEVEL OF EVIDENCE: IV.
引用
- Ulrich MN, Girod MM, Saniei S, et al. Outcomes of Patients Treated With Porous Tantalum Acetabular Reconstruction for Pathologic Acetabular Fractures. J Arthroplasty. 2025. PMID: 41022270. doi:10.1016/j.arth.2025.09.036
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。