文献速递关节外科

短型非骨水泥髋臼柄伴或不伴领的十年随机放射立体测量与双能X线吸收测量研究:柄迁移与骨密度

Stem migration and bone density at ten years : a randomized radiostereometry and dual-energy X-ray absorptiometry study on a short uncemented hip stem with and without a collar.
PubMed 文献 · Bone Joint J · 2025-09-01

50例骨关节炎患者随机接受伴领或不伴领短型非骨水泥髋臼柄全髋关节置换,随访十年。放射立体测量显示术后三个月内早期稳定,此后迁移极小;双能X线吸收测量显示十年净骨密度轻度下降,伴领与否无统计学显著差异。患者报告结局持续良好,无翻修。

要点

  • 伴领与不伴领短柄在十年随访中放射立体测量迁移均极小,两组无统计学显著差异。
  • 十年净骨密度伴领组-3.3%(95%CI -9.2至2.7),不伴领组-2%(95%CI -7.3至3.4),组间无显著差异。
  • 患者报告结局在两组中均改善并维持至十年,无柄翻修。

核心结论

  • 短型非骨水泥髋臼柄在十年时保持稳定并保留骨量,伴领与否均如此;这些发现支持继续使用并进一步评估此类短型非骨水泥柄。

研究设计与样本

  • 随机对照研究,50例因骨关节炎行全髋关节置换的患者(34例男性)随机分配至伴领或不伴领短型非骨水泥髋臼柄组。
  • 患者接受十年重复放射立体测量(RSA)和双能X线吸收测量(DXA)检查,并收集患者报告结局指标(PROMs)、髋关节残疾与骨关节炎结局评分、EuroQol五维问卷和遗忘关节评分。
  • 十年随访时45例患者仍在随访中。

主要发现

  • RSA显示术后三个月内早期植入物稳定和骨整合,初始下沉伴领柄为0.62 mm(95%CI 0.33至0.91),不伴领柄为0.76 mm(95%CI 0.55至0.96)。
  • 至十年时观察到极小进一步迁移。
  • 十年净骨密度伴领柄为-3.3%(95%CI -9.2至2.7),不伴领柄为-2%(95%CI -7.3至3.4)。
  • 领的存在对RSA或DXA结果均未产生任何统计学显著差异。
  • PROMs如预期改善并在两组中维持至十年高位,无柄翻修。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: Short, uncemented hip stems might provide a favourable alternative in total hip arthroplasty (THA) by preserving proximal bone mass through reduced strain-adaptive remodelling. We evaluated and compared the migration and periprosthetic bone remodelling of a short stem with and without a collar, using radiostereometric analysis (RSA) to measure implant migration and dual-energy X-ray absorptiometry (DXA) to evaluate periprosthetic bone remodelling. In this study we present ten-year follow-up results, completing previously published two- and five-year RSA and DXA studies. METHODS: A total of 50 patients (34 males) underwent THA due to osteoarthritis and were randomized to either a collared or collarless short stem. Patients were followed for ten years with repeated RSA and DXA examinations. Patient-reported outcome measures (PROMs), Hip disability and Osteoarthritis Outcome Score, EuroQol five-dimension questionnaire, and Forgotten Joint Score were collected. RESULTS: A total of 45 patients remained at the ten-year follow-up. RSA showed early implant stabilization and osseointegration within three months after an initial subsidence of 0.62 mm (95% CI 0.33 to 0.91) for collared and 0.76 mm (95% CI 0.55 to 0.96) for collarless stems. Minimal further migration was observed up to ten years. Net bone mineral density at ten years was -3.3% (95% CI -9.2 to 2.7) and -2% (95% CI -7.3 to 3.4) in collared and collarless stems, respectively. The presence of a collar did not result in any statistically significant differences either for RSA or DXA results. PROMs improved as expected, and remained high up to ten years in both groups. None of the stems was revised. CONCLUSION: The short stem remains stable at ten years and preserves bone mass, both with and without a collar. These findings support the continued use and further evaluation of this type of short, uncemented stem.

来源:Bone Joint J,查看原文。版权归原作者所有。

引用

  1. Daudi S, Zampelis V, Belfrage O, et al. Stem migration and bone density at ten years : a randomized radiostereometry and dual-energy X-ray absorptiometry study on a short uncemented hip stem with and without a collar. Bone Joint J. 2025. PMID: 40887047. doi:10.1302/0301-620X.107B9.BJJ-2024-1720.R1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。