文献速递关节外科

手术入路不影响单块双动杯初次全髋关节置换术的不稳定风险

Surgical Approach Does Not Influence Instability Risk in Primary Total Hip Arthroplasty With Monobloc Dual Mobility Cup.
PubMed 文献 · J Arthroplasty · 2025-09-06

单中心回顾性队列研究纳入2010至2022年1378例使用单块双动杯的初次全髋关节置换术,其中直接前入路824例、后外侧入路554例,平均随访39个月。直接前入路脱位0例(0%)与后外侧入路2例(0.4%)相比无统计学显著差异(P=0.16)。后外侧入路组主要并发症更多,该组人群年龄更大、超重比例更高、美国麻醉医师协会评分更高。

要点

  • 单块双动杯全髋关节置换中,后外侧入路脱位率不高于直接前入路。
  • 直接前入路脱位0例(0%)vs 后外侧入路2例(0.4%),P=0.16,无统计学显著差异。
  • 后外侧入路组主要并发症更多,该组年龄更大、超重比例更高、美国麻醉医师协会评分更高。

核心结论

  • 在使用单块双动杯的全髋关节置换术中,后外侧入路的脱位率不高于直接前入路。
  • 该大型队列中脱位发生率低,支持使用单块双动杯的获益。

研究设计与样本

  • 单中心回顾性队列研究,证据等级3级。
  • 2010年至2022年间连续完成1378例使用单块双动杯的初次全髋关节置换术,直接前入路824例,后外侧入路554例。
  • 排除标准为骨水泥假体、股骨颈骨折、发育性髋关节发育不良、骨合成并发症及随访不足一年者。
  • 平均随访39个月(范围12至157个月)。

主要发现

  • 直接前入路脱位0例(0%)vs 后外侧入路脱位2例(0.4%),P=0.16,无统计学显著差异。
  • 后外侧入路组主要并发症(如股骨骨折)更多,该组人群年龄更大、超重比例更高、美国麻醉医师协会评分更高。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The impact of the surgical approach on the risk of dislocation in total hip arthroplasty (THA) remains controversial, particularly when monobloc dual mobility cups (DMCs) are used. This study aimed to compare dislocation and complication rates between the postero-lateral and direct anterior approaches (DAAs) with a DMC in primary elective THA, based on data collected from a single center. METHODS: Between 2010 and 2022, 1,378 consecutive primary THAs were performed using a monobloc DMC. There were 824 performed by DAA and 554 by postero-lateral approach (PLA). Exclusion criteria were cemented implants, patients treated for femoral neck fracture, developmental hip dysplasia, osteosynthetic complications, and follow-up of less than one year. Complications and revisions were analyzed retrospectively. The mean follow-up was 39 months (range, 12 to 157). RESULTS: There was no statistically significant difference between the risk of dislocation with the anterior approach (n = 0; 0%) compared with the posterior approach (n = 2; 0.4%) (P = 0.16). There were more major complications, such as femoral fractures, in the PLA group in an older, more overweight, and higher American Society of Anesthesia score population. CONCLUSIONS: In total hip arthroplasty using monobloc DMCs, the dislocation rate with the PLA is no higher than with the DAA. The low incidence of dislocations in this large cohort supports the benefits of using monobloc DMCs. LEVEL OF EVIDENCE: 3, Retrospective Cohort Study.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Machado A, Foissey C, Abdelatif EA, et al. Surgical Approach Does Not Influence Instability Risk in Primary Total Hip Arthroplasty With Monobloc Dual Mobility Cup. J Arthroplasty. 2025. PMID: 40921225. doi:10.1016/j.arth.2025.08.081

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。