文献速递脊柱外科

微创技术实现成人脊柱畸形矫正的理想L1骨盆角能否带来更好结局

Does Achievement of Ideal L1 Pelvic Angle With MIS Techniques in Adult Spinal Deformity Correction Lead to Better Outcomes?
PubMed 文献 · Spine (Phila Pa 1976) · 2025-09-22

基于多中心前瞻性收集的成人脊柱畸形数据库的回顾性队列研究,纳入13个中心1104例患者,比较微创手术与开放手术中达到理想L1骨盆角的比例及结局。微创病例中理想L1骨盆角达标率63%与开放手术61%相似(P=0.342),达标与更低的再手术率和更大的SRS-22总分及SF-36 PCS改善相关。

要点

  • 微创手术中理想L1骨盆角达标率63%,与开放手术61%相似(P=0.342)。
  • 微创患者中达标者再手术率15% vs 未达标者33%(P<0.01)。
  • 微创达标者SRS-22总分改善Δ0.85 vs Δ0.40(P<0.01),SF-36 PCS改善Δ9.1 vs Δ4.6(P=0.04)。

核心结论

  • 在微创手术治疗的成人脊柱畸形患者中,达到理想L1骨盆角与再手术减少和临床结局改善相关,支持其作为关键手术目标。
  • 理想L1骨盆角在微创手术中的达标率与开放手术相似。

研究设计与样本

  • 回顾性队列研究,使用多中心前瞻性收集的成人脊柱畸形数据库。
  • 共纳入13个中心1104例成人脊柱畸形患者,纳入标准为脊柱侧凸≥20°、矢状面垂直轴≥5 cm、骨盆倾斜≥25°或胸椎后凸≥60°,随访≥2年。
  • 微创手术定义为环形微创手术(侧方腰椎椎间融合术/前路腰椎椎间融合术联合经皮后路固定)。
  • 影像学参数和患者报告结局于术前、术后六周及末次随访时收集。
  • 理想L1骨盆角定义为计算目标值±5°以内,计算目标值为(0.5×骨盆入射角)-21。

主要发现

  • 理想L1骨盆角在微创病例中达标率为63%,在开放病例中为61%(P=0.342)。
  • 微创患者中,理想L1骨盆角达标与更低的再手术率相关(15% vs 33%,P<0.01)。
  • 微创患者中,理想L1骨盆角达标与更大的SRS-22总分改善相关(Δ0.85 vs Δ0.40,P<0.01)。
  • 微创患者中,理想L1骨盆角达标与更大的SF-36 PCS评分改善相关(Δ9.1 vs Δ4.6,P=0.04)。
  • 在开放手术组中,理想L1骨盆角与再手术减少无关;在所有患者中,偏离理想L1骨盆角每1°再手术风险增加1.8%(P=0.04)。

关键数值与推荐

  • 理想L1骨盆角定义为计算目标值±5°以内,计算目标值为(0.5×骨盆入射角)-21。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

STUDY DESIGN: Retrospective cohort study using a multicenter, prospectively collected adult spinal deformity (ASD) database. OBJECTIVE: To determine whether achieving the ideal L1 pelvic angle (L1PA) in minimally invasive surgery (MIS) for ASD correction is associated with reduced mechanical failure and improved clinical outcomes. SUMMARY OF BACKGROUND DATA: Prior research has shown that achieving ideal L1PA-defined as (0.5×pelvic incidence)-21-is linked to lower reoperation risk in open ASD correction. Its relevance in MIS has not been well established. METHODS: A total of 1104 ASD patients across 13 centers were included (criteria: scoliosis ≥20°, SVA ≥5 cm, PT ≥25°, or TK ≥60°, with ≥2-year follow-up). Radiographic parameters and patient-reported outcomes (PROs) were collected preoperatively, at six weeks, and at final follow-up. Ideal L1PA was defined as within ±5° of the calculated target. MIS was defined as circumferential MIS (LLIF/ALIF with percutaneous posterior fixation). Associations between alignment and outcomes (reoperation, PROs) were analyzed using linear regression and t tests. RESULTS: Ideal L1PA was achieved in 63% of MIS cases and 61% of open cases ( P =0.342). Among MIS patients, ideal L1PA correlated with lower reoperation rates (15% vs. 33%, P <0.01) and greater improvement in SRS-22 total (Δ0.85 vs. Δ0.40, P <0.01) and SF-36 PCS scores (Δ9.1 vs. Δ4.6, P =0.04). In contrast, ideal L1PA was not associated with reduced reoperation in the open group. Across all patients, each 1° deviation from ideal L1PA increased reoperation risk by 1.8% ( P =0.04). CONCLUSIONS: Ideal L1PA is achievable in MIS at similar rates as open surgery. In MIS-treated ASD patients, achieving ideal alignment is associated with reduced reoperation and improved clinical outcomes, supporting its role as a key surgical target.

来源:Spine (Phila Pa 1976),查看原文。版权归原作者所有。

引用

  1. Khanna R, Eastlack R, Mundis G, et al. Does Achievement of Ideal L1 Pelvic Angle With MIS Techniques in Adult Spinal Deformity Correction Lead to Better Outcomes? Spine (Phila Pa 1976). 2025. PMID: 40980941. doi:10.1097/BRS.0000000000005511

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。