文献速递骨质疏松与代谢性骨病

社区骨质疏松自评工具的性能与干预切点:对筛查和早期转诊的意义

Performance and interventional cutoffs of osteoporosis self-assessment tools in the community: implications for screening and early referral.
PubMed 文献 · Osteoporos Int · 2025-08-20

本研究纳入台湾流行病学队列的1976名受试者(女性占52.8%,平均年龄65.4岁),评估OSTA、OSTAi和MOSTAi等简易自评工具预测骨质疏松的性别和年龄别敏感度与特异度。结果显示eOSTAi在女性中敏感度较好,而eMOSTAi在男性中敏感度一般,且eOSTAi和eMOSTAi检测骨质疏松的切点随年龄下降。结论认为OSTAi切点适合台湾女性自评,而男性MOSTAi切点可能需要调整,并建议根据性别和年龄设置切点。

要点

  • MOSTAi检测骨质疏松的敏感度/特异度为0.53/0.72,OSTA为0.71/0.77,OSTAi为0.77/0.73。
  • 女性中eOSTAi的AUC为骨质疏松0.8200、骨量减少0.7643;男性中eMOSTAi的AUC为0.6690和0.5626。
  • eOSTAi和eMOSTAi检测骨质疏松的切点随年龄下降。

核心结论

  • OSTAi切点适合台湾女性骨质疏松自评;男性MOSTAi切点可能需要调整;建议按性别和年龄设置切点。

研究设计与样本

  • 研究纳入台湾流行病学队列调查的受试者,通过OSTA(针对亚洲女性)、OSTAi和MOSTAi(针对台湾女性和男性)评估骨质疏松风险。
  • 骨质疏松定义为腰椎和髋部DXA测量的最低T值≤-2.5。
  • 采用OSTAi和MOSTAi算法,通过ROC和AUC分析自评性能。

主要发现

  • 共纳入1976名参与者,女性占52.8%,平均年龄65.4岁。
  • 检测骨质疏松的敏感度/特异度:MOSTAi为0.53/0.72,OSTA为0.71/0.77,OSTAi为0.77/0.73。
  • 女性中eOSTAi的AUC为骨质疏松0.8200、骨量减少0.7643;男性中eMOSTAi的AUC为骨质疏松0.6690、骨量减少0.5626。
  • eOSTAi和eMOSTAi检测骨质疏松的切点随年龄下降。

关键数值与推荐

  • OSTA检测骨质疏松的敏感度/特异度为0.71/0.77。
  • OSTAi检测骨质疏松的敏感度/特异度为0.77/0.73。
  • MOSTAi检测骨质疏松的敏感度/特异度为0.53/0.72。
  • 女性eOSTAi的AUC为骨质疏松0.8200、骨量减少0.7643;男性eMOSTAi的AUC为骨质疏松0.6690、骨量减少0.5626。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

UNLABELLED: Patients with lower bone mineral density (BMD) face an increased risk of fragile fractures and should be actively screened to mitigate this vulnerability. Given the limitations of dual-energy X-ray absorptiometry (DXA), it is possible to identify high-risk osteoporosis groups through simple self-assessment tools for further BMD measurements. PURPOSE: This study aims to evaluate the sex- and age-specific sensitivity and specificity of these simple tools for predicting osteoporosis risk to enhance the overall management of osteoporosis risk in the community. METHODS: This study enrolled subjects surveyed from epidemiological cohorts in Taiwan. Osteoporosis risk was assessed via the OSTA (for Asian women), and the OSTAi and MOSTAi (for Taiwanese women and men). Osteoporosis was defined as the lowest T-score ≤ - 2.5 based on the BMD of the lumbar spine and hip, as measured via DXA. The OSTAi and MOSTAi algorithms were used to analyze the self-assessment performance via receiver operating characteristic (ROC) and area under the curve (AUC) analyses. RESULTS: A total of 1976 participants were enrolled in the study; 52.8% were women, with a mean age of 65.4 years. The sensitivity and specificity for detecting osteoporosis were as follows: MOSTAi (sensitivity/specificity = 0.53/0.72), OSTA (0.71/0.77), and OSTAi (0.77/0.73). The eOSTAi demonstrated favorable sensitivity in women, with AUCs of 0.8200 for osteoporosis and 0.7643 for osteopenia. In men, eMOSTAi showed fair sensitivity (AUC = 0.6690 for osteoporosis and 0.5626 for osteopenia). The cutoffs of the eOSTAi and eMOSTAi for detecting osteoporosis decreased with age. CONCLUSION: The cutoff of OSTAi is suitable for self-assessment of osteoporosis in Taiwanese women. However, for men, the cutoff of MOSTAi may need to be adjusted. Considering the differences in the prevalence of osteoporosis in the community, it is recommended that the cutoff be set according to gender and age.

来源:Osteoporos Int,查看原文。版权归原作者所有。

引用

  1. Li CC, Ou LC, Chang YF, et al. Performance and interventional cutoffs of osteoporosis self-assessment tools in the community: implications for screening and early referral. Osteoporos Int. 2025. PMID: 40833502. doi:10.1007/s00198-025-07656-1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。