文献速递关节外科

36毫米头与32毫米头在全髋关节置换术中累积翻修率比较:澳大利亚骨科协会国家关节置换登记研究

Does a 36-mm Head Increase Cumulative Revision Rate in Total Hip Arthroplasty When Compared to a 32-mm Head? A Study From the Australian Orthopaedic Association National Joint Replacement Registry.
PubMed 文献 · J Arthroplasty · 2025-08-18

基于澳大利亚骨科协会国家关节置换登记(AOANJRR)1999年9月至2022年12月共272,258例陶瓷或金属头全髋关节置换(THA)数据,分析36毫米与32毫米头的累积翻修率。

要点

  • 36毫米头因骨折(HR 1.30)和松动(HR 1.21)翻修显著增多。

核心结论

  • 本研究显示较大头尺寸与累积翻修率升高相关,该差异在金属对高交联聚乙烯关节面、前路手术及65岁以下男性54-55毫米杯尺寸中最明显,在65岁及以上男性中仍存在但程度较轻。
  • 女性模式相似,但不如男性明显;比较36毫米与32毫米头,36毫米头早期脱位翻修减少,但骨折和松动翻修增加。
  • 随着AOANJRR及其他地区大头尺寸使用增加,需考虑特定亚组中较大头尺寸是否带来预期生存优势。

研究设计与样本

  • 基于澳大利亚骨科协会国家关节置换登记(AOANJRR)1999年9月至2022年12月所有陶瓷和金属头、高交联聚乙烯全髋关节置换(THA)数据,共272,258例THA。
  • 分析THA后累积翻修率(CPR),并对32毫米和36毫米头按年龄、固定方式、手术入路、杯尺寸和关节面进行亚组分析。

主要发现

  • 亚组分析显示差异因年龄、性别、手术入路、杯尺寸和关节面而异。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Registry and industry data show increasing utilization of large (36 mm) heads in primary total hip arthroplasty (THA). Recent analysis of the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) has reported reduced dislocation rates with 36 mm heads compared to 32- and 28-mm heads; however, the effect of age, fixation, approach, cup size, and bearing surface upon revision risk and head size has not been examined, with little data on all-cause revision. METHODS: The AOANJRR data were examined for all ceramic and metal head THA with highly crosslinked polyethylene between September 1999 and December 2022. There were 272,258 THAs identified. Cumulative percent revision (CPR) following THA was examined with further subanalysis of age, fixation, approach, cup size, and bearing surface for 32- and 36-mm heads. RESULTS: The CPR was higher for 36 mm heads from 1 month (HR [hazard ratio] 1.14 (1.08 to 1.20), P < 0.001). Subgroup analysis showed these differences varied depending on age, sex, approach, cup size, and bearing surface. There were differences in reasons for revision between head sizes, with significantly more revisions with 36 mm heads for fracture (HR 1.30 (1.18 to 1.42), P < 0.001), particularly for ≥ 65-year-olds, and loosening (HR 1.21 (1.09 to 1.34, P < 0.001), and significantly more revisions for dislocation (to a lesser degree) with 32 mm heads (HR 1.18 (1.07 to 1.30), P < 0.001). CONCLUSIONS: Our study shows an association between larger head size and increased CPR. This difference is most clearly seen in metal-on-highly crosslinked polyethylene articulations, anterior approach, and 54- to 55-mm cup size in men < 65 years, although it still exists to a lesser extent in men ≥ 65 years. For women, the pattern was similar, although not as apparent. Comparing 36- to 32-mm heads, 36 mm showed reduced early dislocation; however, revision for fracture and loosening was increased. With an increasing trend toward larger head sizes both in the AOANJRR and elsewhere, consideration must be given in these particular subgroups as to whether larger head size confers the intended survival advantages.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Wallace DT, Whitehouse SL, Du P, et al. Does a 36-mm Head Increase Cumulative Revision Rate in Total Hip Arthroplasty When Compared to a 32-mm Head? A Study From the Australian Orthopaedic Association National Joint Replacement Registry. J Arthroplasty. 2025. PMID: 40835012. doi:10.1016/j.arth.2025.08.014

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。