机器人辅助全髋关节置换术治疗关节融合髋的侧方髋臼配准技术:一项为期一年随访的回顾性队列研究
该回顾性队列研究纳入2021年1月至2023年10月在本院接受全髋关节置换术的强直性脊柱炎患者,比较机器人辅助(60例)与手工(60例)手术。机器人组髋臼假体位于安全区的比例更高(93.3%对55.0%),脱位率更低(1.7%对5.0%),术后一年Harris髋关节评分更高(77.9±4.9对70.4±4.8)。
要点
- 机器人组髋臼假体位于安全区的比例为93.3%,高于对照组的55.0%。
- 机器人组脱位率为1.7%,低于手工组的5.0%。
- 术后一年机器人组Harris髋关节评分为77.9±4.9,高于手工组的70.4±4.8。
核心结论
- 机器人辅助全髋关节置换术可显著降低强直性脊柱炎患者的脱位率并提高患者满意度。
研究设计与样本
- 回顾性分析2021年1月至2023年10月在本院接受全髋关节置换术的强直性脊柱炎患者,机器人辅助组60例,手工组60例,两组人口学特征无显著差异,术后随访一年。
主要发现
- 两组手术时间分别为105.5±8.8分钟与104.2±7.1分钟,无统计学显著差异。
- 机器人组透视频率为0次,低于手工组的0.8±0.8次。
- 机器人辅助组髋臼假体位于安全区的比例为93.3%,高于对照组的55.0%。
- 机器人辅助组脱位率为1.7%,显著低于手工组的5.0%。
- 机器人辅助组并发症发生率为3.3%,手工手术组为8.3%。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The hip joint is one of the peripheral joints most commonly affected by ankylosing spondylitis (AS). Previous research showed that compared to manual total hip arthroplasty (THA), robot-assisted THA significantly improves the likelihood of achieving cup positioning within the target zone. METHODS: In this study, we investigated robot-assisted THA for arthrodesed hips, including fused hip joints and fibrously fused hip joints. We retrospectively analyzed patients who had AS who underwent THA in our hospital from January 2021 to October 2023. There were 60 patients who underwent robot-assisted THA, and 60 patients received manual THA. There was no significant difference in demographic characteristics between the two groups. The patients were followed up at one year after surgery. We collected the patient's sex, age, body mass index, operative time, postoperative anteroposterior pelvic X-ray, postoperative Harris hip score, intraoperative and postoperative complications. RESULTS: The operation time of the two groups was 105.5 ± 8.8 versus 104.2 ± 7.1 minutes, with no statistically significant difference. In addition, the frequency of fluoroscopy was lower in the robot group than in the manual group (0 versus 0.8 ± 0.8). The proportion of acetabular prosthesis in the safety zone in the robot-assisted group was higher than that in the control group (93.3 and 55.0%). The dislocation rate of the robot-assisted group was significantly less than that of the manual group (1.7 versus 5.0%). The complication rate of the robot-assisted group was 3.3%, and that of the manual surgery group was 8.3%. At one year after surgery, the Harris hip score of patients in the robot-assisted group was higher than that in the manual group (77.9 ± 4.9 versus 70.4 ± 4.8), with a statistical difference. CONCLUSIONS: We demonstrate that robot-assisted THA in AS patients significantly reduces dislocation rates and improves patient satisfaction.
引用
- Zhi X, Wang L, Kong X, et al. The Lateral Acetabular Registration Technique of Robot-Assisted Total Hip Arthroplasty for Arthrodesed Hips: A Retrospective Cohort Study With a One-Year Follow-Up. J Arthroplasty. 2025. PMID: 40750060. doi:10.1016/j.arth.2025.07.054
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。