文献速递关节外科

第三代氧化铝-氧化铝陶瓷或氧化铝-高交联聚乙烯轴承的非骨水泥全髋关节置换术:20至30年随访

Cementless Total Hip Arthroplasty Using a Third-Generation Alumina-On-Alumina Ceramic or Alumina-On-Highly Cross-Linked Polyethylene Bearing: 20- to 30-Year Follow-Up.
PubMed 文献 · J Arthroplasty · 2025-08-18

研究纳入250例(500髋)年龄<65岁的双侧全髋关节置换患者,一侧随机接受氧化铝陶瓷-陶瓷(C-O-C)轴承,对侧接受氧化铝陶瓷-高交联聚乙烯(C-O-HXLPE)轴承。平均随访25.5年,两组均无骨溶解,HXLPE内衬平均聚乙烯穿透率为0.041±0.005 mm/年,两组假体生存率均较高,临床功能评分均显著改善。

要点

  • 平均随访25.5年,C-O-C与C-O-HXLPE两组均无骨溶解发生。
  • HXLPE内衬平均聚乙烯穿透率为0.041±0.005 mm/年。
  • 两组临床功能评分(Harris髋关节评分、WOMAC评分、UCLA活动评分)末次随访均显著改善(P<0.05)。

核心结论

  • 平均随访25.5年,采用干骺端固定解剖型非骨水泥股骨柄与氧化铝C-O-C或氧化铝C-O-HXLPE轴承的全髋关节置换术表现出优异的长期功能,无骨溶解,无陶瓷股骨头或髋臼内衬骨折。

研究设计与样本

  • 连续行初次全髋关节置换术的250例患者(500髋;140例男性,110例女性),年龄<65岁;为双侧全髋关节置换患者系列,随机一侧接受C-O-C轴承、对侧接受C-O-HXLPE轴承;置换时平均年龄45岁(范围31至65岁),平均随访25.5年(范围20至30年)。

主要发现

  • 两组均无髋关节发生骨溶解。
  • HXLPE内衬平均聚乙烯穿透率为0.041±0.005 mm/年。
  • C-O-C轴承组股骨组件生存率为96.8%(95%CI 92至100),髋臼组件生存率为97.2%(95%CI 92至100),平均随访25.5年。
  • C-O-HXLPE轴承组股骨与髋臼组件生存率均为97.6%(95%CI 92至100),平均随访25.5年。
  • 两组临床与功能结果(Harris髋关节评分、西安大略和麦克马斯特大学骨关节炎指数评分、加州大学洛杉矶分校活动评分)末次随访均显著改善(P<0.05)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: We determined the long-term (≥ 20 years) clinical outcomes of metaphyseal-fitting anatomic cementless implants with alumina ceramic-on-ceramic (C-O-C) or alumina ceramic-on-highly cross-linked polyethylene (C-O-HXLPE) bearings. METHODS: Consecutive primary total hip arthroplasty (THA) procedures were performed in 250 patients (500 hips; 140 men, 110 women) aged < 65 years. This is a series of bilateral THA patients who were randomized to receive a C-O-C bearing on one side and a C-O-HXLPE on the contralateral side. The mean age at the time of THA was 45 years (range, 31 to 65), with a mean follow-up of 25.5 years (range, 20 to 30). Osteolysis was assessed using radiographs and computed tomography scans, whereas polyethylene wear was measured using a computer software program. RESULTS: There was no hip in either group that had osteolysis. The mean polyethylene penetration rate of the HXLPE liner was 0.041 ± 0.005 mm/year. The survival rate in the C-O-C bearing group was 96.8% (95% confidence interval [CI], 92 to 100) for the femoral component and 97.2% (95% CI, 92 to 100) for the acetabular component at a mean of 25.5 years of follow-up. In the C-O-HXLPE bearing group, the survival rate for both femoral and acetabular components was 97.6% (95% CI, 92 to 100) at a mean of 25.5 years of follow-up. The clinical and functional results (Harris Hip Score, Western Ontario and McMaster Universities Osteoarthritis Index score, and University of California, Los Angeles, activity score) improved significantly (P < 0.05) at the final follow-up in both groups. CONCLUSIONS: At a mean follow-up of 25.5 years, a metaphyseal-fitting anatomic cementless femoral stem with alumina C-O-C or alumina C-O-HXLPE bearings demonstrated excellent long-term function, with no osteolysis and no ceramic femoral head or acetabular liner fractures.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Kim YH, Park JW, Jang YS, et al. Cementless Total Hip Arthroplasty Using a Third-Generation Alumina-On-Alumina Ceramic or Alumina-On-Highly Cross-Linked Polyethylene Bearing: 20- to 30-Year Follow-Up. J Arthroplasty. 2025. PMID: 40835011. doi:10.1016/j.arth.2025.08.018

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。