内侧轴型假体用于治疗中重度畸形
回顾性队列研究分析2017至2020年164例(101例内侧轴型、63例后稳定型)伴有大于10度内翻畸形的原发性膝骨关节炎全膝关节置换患者,随访40个月。两组功能KSS中位数均为90但差异有统计学意义(P<0.01),客观KSS无显著差异,并发症无显著差异。作者认为内侧轴型设计可考虑作为中重度内翻畸形的替代选择。
要点
- 内侧轴型与后稳定型假体功能KSS中位数均为90,但功能KSS差异有统计学意义(P<0.01),支持内侧轴型。
- 客观KSS后稳定型85 vs 内侧轴型84(P=0.57),无临床重要差异。
- 两组并发症无显著差异,96.1%患者显示临床改善。
核心结论
- 作者观察到该系列中90%的患者使用两种假体均获得临床相关改善,内侧轴型设计可考虑作为中重度内翻畸形的替代治疗。
- 两组功能KSS中位数相等(90),但功能KSS评估差异有统计学意义,支持内侧轴型设计;客观KSS评估无显著差异。
研究设计与样本
- 回顾性队列研究,分析2017年至2020年因原发性膝骨关节炎伴大于10度内翻畸形行全膝关节置换的患者。
- 共164例患者(101例内侧轴型,63例后稳定型)符合纳入标准,两组随访40个月。
- 所有手术由同一手术团队按照标准化技术完成,以实现调整机械力线。
主要发现
- 术后1年功能KSS:内侧轴型90(80.0至100) vs 后稳定型90(75.8至90.0),P<0.01。
- 术后1年客观KSS:后稳定型85(70.0至94.0) vs 内侧轴型84(74.0至93.2),P=0.57,无临床重要差异。
- 两组KSS改善均有统计学意义,96.1%的患者显示临床改善。
- 两组并发症无显著差异。
临床怎么用
- 作者认为内侧轴型设计可考虑作为中重度内翻畸形的替代治疗。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Total knee arthroplasty is the standard treatment for advanced knee osteoarthritis. Medial pivot (MP) prostheses aim to better replicate native knee biomechanics, but their efficacy in moderate to severe deformities remains unclear compared to posterior-stabilized (PS) designs or more constrained implants. METHODS: A retrospective cohort study was conducted, analyzing patients who had primary knee osteoarthritis and > 10° varus deformity who underwent total knee arthroplasty with either an MP or PS prosthesis between 2017 and 2020. A total of 164 patients (101 MP and 63 PS) met the inclusion criteria. There were no significant demographic differences found between groups, with 40-month follow-ups in both groups. Functional outcomes were assessed using the Knee Society Score (KSS) and visual analog scale for pain. Complications and implant survival were also evaluated. All surgeries were performed by the same surgical team, following a standardized technique to achieve adjusted mechanical alignment. RESULTS: At 1 year, the functional KSS was similar between MP (90 [80.0 to 100]) and PS (90 [75.8 to 90.0]) (P < 0.01). The objective KSS was 85 (70.0 to 94.0) in the PS versus 84 (74.0 to 93.2) in the MP group, P = 0.57, with no clinically important difference. Improvement in KSS was significant in both groups, with 96.1% showing clinical improvement. There were no significant differences found in complications. CONCLUSIONS: We observed that 90% of the series achieved clinically relevant improvement with both implants, showing that the use of MP designs could be considered an alternative for the treatment of moderate to severe varus deformities. When comparing both groups, although medians were equal (90), there was a significant difference in functional KSS evaluation in favor of the MP design, whereas the clinical objective KSS evaluation showed no significant difference.
引用
- Principe F, De Iure CV, Sanchez Mele HG, et al. The Use of Medial Pivot Prostheses for the Treatment of Moderate and Severe Deformities. J Arthroplasty. 2025. PMID: 40812460. doi:10.1016/j.arth.2025.07.074
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。