文献速递关节外科

全髋关节置换术中高交联聚乙烯的20年随访生存率

Survivorship of Highly Cross-Linked Polyethylene in Total Hip Arthroplasty: 20-Year Follow-Up.
PubMed 文献 · J Arthroplasty · 2025-08-26

本研究回顾性分析了1999至2003年由单一术者行全髋关节置换并置入高交联聚乙烯内衬的89例患者,其中66例进行磨损率分析。20年全因翻修生存概率为93.5%(95%CI 88.2至99.2),因骨溶解翻修生存概率为98.6%(95%CI 95.9至99.9),平均线性磨损率为0.06±0.07毫米/年。

要点

  • 89例中7例翻修(7.9%),其中骨溶解1例(14.3%)、感染2例(28.6%)、脱位4例(57.1%)。
  • 66例磨损分析显示平均线性磨损率0.06±0.07毫米/年,平均体积磨损率11.8±13.2立方毫米/年。
  • 20年全因翻修生存概率93.5%(95%CI 88.2至99.2),骨溶解翻修生存概率98.6%(95%CI 95.9至99.9)。

核心结论

  • 使用高交联、电子束辐射和熔融退火聚乙烯内衬时,仅1例患者因骨溶解接受翻修。
  • 该内衬表现出极低的体积和线性磨损率,并在20年随访后显示出优异的长期生存率。

研究设计与样本

  • 回顾性审查本机构1999至2003年的电子病历,纳入由单一接受专科培训的骨科医生行全髋关节置换并置入高交联聚乙烯且有20年随访的患者。
  • 排除缺乏适当随访或足够电子病历数据或电话无法联系的患者,共89例患者纳入翻修率分析。
  • 由独立审查者使用计算机软件比较最早髋关节X线片与近期随访图像以量化磨损,66例患者进行磨损率分析。

主要发现

  • 大多数患者因终末期原发性骨关节炎接受手术(70.8%)。
  • 89例患者中7例翻修(7.9%);翻修原因中骨溶解1例(14.3%)、感染2例(28.6%)、脱位4例(57.1%)。
  • 66例磨损分析显示平均线性磨损率0.06±0.07毫米/年,平均体积磨损率11.8±13.2立方毫米/年。
  • 20年时该聚乙烯全因翻修生存概率为93.5%(95%CI 88.2至99.2),因骨溶解翻修生存概率为98.6%(95%CI 95.9至99.9)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: In this study, we investigated the 20-year wear properties and survivorship of a highly cross-linked polyethylene liner (PE) used in total hip arthroplasty. We expected wear properties of less than one mm/year and improved survivorship when compared to the current literature after 20 years of follow-up. METHODS: A retrospective review of our institution's electronic medical record was conducted from 1999 to 2003. Patients who underwent total hip arthroplasty by a single fellowship-trained orthopedic surgeon with placement of a highly cross-linked polyethylene with 20-year follow-up were included. Patients who lacked appropriate follow-up or adequate electronic medical record data, or who were unreachable via telephone were excluded. In total, 89 patients were reviewed to determine revision rates. In addition, the earliest hip radiographs were compared to recent follow-up images via an independent reviewer utilizing computer software to quantify wear. RESULTS: The majority of patients underwent surgery secondary to end-stage primary osteoarthritis (70.8%). Out of 89 patients, there were seven revisions (7.9%). Of those revisions, one was secondary to osteolysis (14.3%), two were due to infection (28.6%), and four were due to dislocation (57.1%). There were 66 patients who underwent wear rate analysis, showing a mean linear wear rate of 0.06 ± 0.07 (mm/year). The mean volumetric wear rate was 11.8 ± 13.2 (mm3/year). At 20 years, the survival probability of this PE for all-cause revision was 93.5% (95% confidence interval: 88.2 to 99.2), while the survival probability for revision due to osteolysis was 98.6% (95% confidence interval: 95.9 to 99.9). CONCLUSIONS: When utilizing a highly cross-linked, electron beam-radiated, and melt-annealed PE, only one patient underwent revision for osteolysis. Implementation of these liners demonstrates minimal volumetric and linear wear rates and shows excellent long-term survivability after 20 years follow-up.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Thandoni A, Andreini DE, Trivedi AH, et al. Survivorship of Highly Cross-Linked Polyethylene in Total Hip Arthroplasty: 20-Year Follow-Up. J Arthroplasty. 2025. PMID: 40876661. doi:10.1016/j.arth.2025.08.058

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。