文献速递关节外科

全膝关节置换术胫骨骨缺损骨水泥-螺钉技术的生物力学分析

Biomechanical Analysis of Cement-Screw Technique for Tibial Bone Defects in Total Knee Arthroplasty.
PubMed 文献 · J Arthroplasty · 2025-08-12

本研究通过有限元分析和生物力学测试,探讨全膝关节置换术胫骨骨缺损骨水泥-螺钉技术中螺钉的最佳植入角度。螺钉相对于胫骨机械轴分为0°、15°、30°和45°四组,结果显示15°植入角度时螺钉、缺损区骨水泥、假体及假体下骨水泥的最大应力最小,螺钉位移最小,模型位移最小且结构刚度最大。结论认为15°螺钉植入角度在骨水泥-螺钉技术中具有生物力学优势。

要点

  • 有限元分析显示螺钉植入角度为15°时,螺钉、缺损区骨水泥、假体及假体下骨水泥的最大应力最小,螺钉位移最小。
  • 生物力学测试表明15°螺钉植入角度下模型位移最小、结构刚度最大。
  • 结论认为15°螺钉植入角度在骨水泥-螺钉技术修复全膝关节置换术胫骨骨缺损中具有生物力学优势。

核心结论

  • 螺钉植入角度为15°时,在骨水泥-螺钉技术修复全膝关节置换术胫骨骨缺损中具有生物力学优势。

研究设计与样本

  • 研究将螺钉植入角度相对于胫骨机械轴分为0°、15°、30°和45°四组,采用有限元分析评估各组模型的应力分布和位移。
  • 进行静态压缩力学测试评估各组模型产生的位移,并进行高循环疲劳压缩测试评估各组模型的位移和结构刚度。

主要发现

  • 有限元分析结果显示,螺钉植入角度为15°时,螺钉、缺损区骨水泥、假体及假体下骨水泥的最大应力最小,螺钉位移最小。
  • 生物力学测试结果显示,15°螺钉植入角度下模型位移最小、结构刚度最大。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The cement-screw technique stands out as an effective method for addressing tibial bone defects in total knee arthroplasty (TKA). However, the absence of consensus regarding the optimal angle for screw implantation poses a challenge. This study aimed to investigate the most suitable screw implantation angle for repairing tibial bone defects in TKA, with a focus on biomechanical considerations. METHODS: The angle of screw implantation was categorized into four groups: 0, 15, 30, and 45° relative to the tibial mechanical axis. Finite-element analysis was used to assess stress distribution and displacement in each group model. Static compression mechanical tests were conducted to evaluate the displacement generated by each group model. In addition, high-cycle fatigue compression tests were performed to assess the displacement and structural stiffness of each group model. RESULTS: The finite-element analysis results indicated that at a screw implantation angle of 15°, the maximum stress on the screw, cement in the defect, prosthesis, and cement under prosthesis is minimized, with the least displacement of the screw. Biomechanical test results demonstrated that a 15° screw implantation angle led to minimum displacement and maximal structural stiffness in the model. CONCLUSIONS: The screw implantation angle of 15° provides a biomechanical advantage in the cement-screw technique context for TKA tibial bone defects.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Liu D, Lu Q, Li X, et al. Biomechanical Analysis of Cement-Screw Technique for Tibial Bone Defects in Total Knee Arthroplasty. J Arthroplasty. 2025. PMID: 40812458. doi:10.1016/j.arth.2025.08.004

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。